In developing countries with high seismic activity, a need exists to construct resilient infrastructure and reduce the housing deficit. Industrialized timber construction and the implementation of seismic isolation interfaces may represent a good alternative to respond to these demands. This paper studies the feasibility of constructing cross-laminated timber (CLT) buildings equipped with frictional pendulum bearings in Chile or similar highly seismic regions. The first part of this study shows a first-order approach for modeling the highly nonlinear behavior of CLT walls using a Smooth Hysteretic Model (SHM). An equivalent model of a base-isolated building was developed using the SHM as well as a physical model of the Friction Pendulum System in order to assess the seismic performance of CLT buildings with frictional isolators. The second part of this research presents and discusses the results of a broad parametric analysis concerning the seismic performance of base-isolated CLT buildings. The seismic assessment was carried out by deriving fragility curves and including the uncertainty linked to the seismic input and the friction coefficient of the isolation system. Constructing lateral resistant systems based on CLT walls presents a feasible alternative for buildings in high seismic hazard areas. Excellent seismic performance is achieved if the superstructure’s is designed with a reduction factor of 1, or if the superstructure’s fundamental period ranges from 0.6 to 0.9 s and is designed with a reduction factor of 2 and ductility capacity of 6 or more. An excellent seismic performance can be obtained for larger reduction factor values if the superstructure has middle to high maximum ductility capacity.
Due to their potential to reduce greenhouse gas emissions, light-frame timber buildings (LFTBs) are widely used in seismically active regions. However, their construction in these areas remains limited, primarily due to the high costs associated with continuous anchor tie systems (ATSs), which are required to withstand significant seismic forces. To address this challenge, frictional seismic isolation offers an alternative by enhancing seismic protection. Although frictional base isolation is an effective mitigation strategy, its performance can be compromised by extreme ground motions that induce large lateral displacements, resulting in impacts between the sliders and the perimeter protection ring. The effects of these internal lateral impacts on base-isolated LFTBs remain largely unexplored. To fill this knowledge gap, this study evaluates the collapse capacity of a set of base-isolated LFTBs representative of Chilean real estate developments. Nonlinear numerical models were developed in the OpenSeesPy platform to capture the nonlinear behavior of the superstructure, including the impact effects within the frictional isolation system. Incremental dynamic analyses following the FEMA P695 methodology were performed using subduction ground motions. Collapse margin ratios (CMRs) and fragility curves were derived to quantify seismic performance. Results indicate that frictional base-isolated LFTBs can achieve acceptable collapse safety without ATS, even with compact-size bearings. Code-conforming archetypes achieved CMRs ranging from 1.24 to 1.55, indicating sufficient safety margins. These findings support the cost-effective implementation of frictional base isolation in mid-rise timber construction for high-seismic regions.