Background: In oncology, the correct determination of nodal metastatic disease is essential for patient management, as patient treatment and prognosis are closely linked to the stage of the disease. The aim of the study was to develop a tool for automatic 3D detection and segmentation of lymph nodes (LNs) in computed tomography (CT) scans of the thorax using a fully convolutional neural network based on 3D foveal patches.Methods: The training dataset was collected from the Computed Tomography Lymph Nodes Collection of the Cancer Imaging Archive, containing 89 contrast-enhanced CT scans of the thorax. A total number of 4275 LNs was segmented semi-automatically by a radiologist, assessing the entire 3D volume of the LNs. Using this data, a fully convolutional neuronal network based on 3D foveal patches was trained with fourfold cross-validation. Testing was performed on an unseen dataset containing 15 contrast-enhanced CT scans of patients who were referred upon suspicion or for staging of bronchial carcinoma.Results: The algorithm achieved a good overall performance with a total detection rate of 76.9% for enlarged LNs during fourfold cross-validation in the training dataset with 10.3 false-positives per volume and of 69.9% in the unseen testing dataset. In the training dataset a better detection rate was observed for enlarged LNs compared to smaller LNs, the detection rate for LNs with a short-axis diameter (SAD) ≥ 20 mm and SAD 5–10 mm being 91.6% and 62.2% (p < 0.001), respectively. Best detection rates were obtained for LNs located in Level 4R (83.6%) and Level 7 (80.4%).Conclusions: The proposed 3D deep learning approach achieves an overall good performance in the automatic detection and segmentation of thoracic LNs and shows reasonable generalizability, yielding the potential to facilitate detection during routine clinical work and to enable radiomics research without observer-bias.
We evaluated the contribution of lung lesion quantification on chest CT using a clinical Artificial Intelligence (AI) software in predicting death and intensive care units (ICU) admission for COVID-19 patients. For 349 patients with positive COVID-19-PCR test that underwent a chest CT scan at admittance or during hospitalization, we applied the AI for lung and lung lesion segmentation to obtain lesion volume (LV), and LV/Total Lung Volume (TLV) ratio. ROC analysis was used to extract the best CT criterion in predicting death and ICU admission. Two prognostic models using multivariate logistic regressions were constructed to predict each outcome and were compared using AUC values. The first model ("Clinical") was based on patients' characteristics and clinical symptoms only. The second model ("Clinical+LV/TLV") included also the best CT criterion. LV/TLV ratio demonstrated best performance for both outcomes; AUC of 67.8% (95% CI: 59.5 - 76.1) and 81.1% (95% CI: 75.7 - 86.5) respectively. Regarding death prediction, AUC values were 76.2% (95% CI: 69.9 - 82.6) and 79.9% (95%IC: 74.4 - 85.5) for the "Clinical" and the "Clinical+LV/TLV" models respectively, showing significant performance increase (+ 3.7%; p-value<0.001) when adding LV/TLV ratio. Similarly, for ICU admission prediction, AUC values were 74.9% (IC 95%: 69.2 - 80.6) and 84.8% (IC 95%: 80.4 - 89.2) respectively corresponding to significant performance increase (+ 10%: p-value<0.001). Using a clinical AI software to quantify the COVID-19 lung involvement on chest CT, combined with clinical variables, allows better prediction of death and ICU admission.
Background/Objectives: Accurate and reproducible lymph node (LN) measurement is essential for oncologic staging and therapy monitoring but is subject to inter-reader variability. This study evaluated the accuracy and reproducibility of a fully automated artificial intelligence (AI)-based LN measurement workflow in contrast-enhanced chest CT, using multi-reader manual measurements as reference. Methods: Sixty thoracic LNs from seven patients were independently measured by 13 radiologists in two reading rounds. The median of all measurements served as the ground truth (GT). Automated short- and long-axis diameters were derived from fully automated 3D CNN-based segmentations. Agreement between AI and manual measurements was assessed using Friedman testing, intraclass correlation coefficients (ICCs), and concordance correlation coefficients (CCCs). Measurement stability was evaluated across repeated runs on different hardware systems. Results: A total of 2280 manual measurements were analyzed. Manual assessment showed significant inter-reader variability (p < 0.01), while intra-reader agreement was high. No significant differences were observed between AI-based measurements and the GT (all p > 0.01). Agreement was good, with CCC values of 0.86 (SAD) and 0.79 (LAD). AI-based measurements were numerically stable across hardware configurations. Conclusions: Fully automated AI-based LN measurements in chest CT scans provide strong agreement with multi-reader consensus and high numerical stability. Automated measurement may support more standardized and reproducible oncologic imaging assessment.
Background/Objectives: Accurate assessment of lymph nodes is of paramount importance for correct cN staging in head and neck cancer; however, it is very time-consuming for radiologists, and lymph node metastases of head and neck cancers may show distinct characteristics, such as central necrosis or very large size. Here, we evaluate the performance of a previously developed generic cervical lymph node segmentation model in a cohort of patients with head and neck cancer. Methods: In our retrospective single-center, multi-vendor study, we included 125 patients with head and neck cancer with at least one untreated lymph node metastasis. On the respective cervical CT scan, an experienced radiologist segmented lymph nodes semi-automatically. All 3D segmentations were confirmed by a second reader. These manual segmentations were compared to segmentations generated by an AI model previously trained on a different dataset of varying cancers. Results: In cervical CT scans from 125 patients (61.9 years ± 10.6, 100 men), 3656 lymph nodes were segmented as ground-truth, including 544 clinical metastases. The AI achieved an average recall of 0.70 with 6.5 false positives per CT scan. The average global Dice accounts for 0.73 per scan, with an average Hausdorff distance of 0.88 mm. When analyzing the individual nodes, segmentation accuracy was similar for non-metastatic and metastatic lymph nodes, with a sensitivity of 0.89 and 0.85. Localization performance was lower for metastatic than for non-metastatic lymph nodes, with a recall of 0.65 and 0.74, respectively. Model performance was worse for enlarged nodes (short-axis diameter ≥ 15 mm), with a recall of 0.36 and a sensitivity of 0.67. Conclusions: The AI model for generic cervical lymph node segmentation shows good performance for smaller nodes (SAD ≤ 15 mm) with respect to localization and segmentation accuracy. However, for clearly enlarged and necrotic nodes, a retraining of the generic AI algorithm seems to be required for accurate cN staging.