Jae-Eun Kim

Ms. Jae-Eun Kim

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YYYoungjae Yoon
Youngjae Yoon
JKJae-Eun Kim
Jae-Eun Kim
EKEunji Kim
Eunji Kim
SPSoyeon Park
Soyeon Park
IKInyeong Kang
Inyeong Kang
YKYong-Dae Kwon
Yong-Dae Kwon
Peri-implant bone loss and bone quality significantly affect the biomechanical stability and long-term success of dental implants. This study used finite element analysis to evaluate the stress distribution and deformation behavior of implants and alveolar bone according to bone loss (0–5 mm) and bone quality (normal and low). A finite element model was implemented based on a three-dimensional mandibular model. The mechanical properties of each component were assigned, and finite element analysis was performed using a static occlusal load. The results showed that progressive bone loss increased von Mises stresses in the implant fixture and surrounding bone, and low-quality bone showed a significant vulnerability to stress concentration. The 2 mm bone loss model showed the maximum stress in cortical bone, and from 3 mm onwards, the stress decreased due to extensive loss of cortical bone. This may be because extensive bone loss causes the implant to lose interface with cortical bone and contact only with cancellous bone. This study confirmed that bone loss and the vulnerability of bone quality may potentially affect implant failure. Continued research is needed to suggest customized implants based on the structural vulnerability of alveolar bone.

10 December 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
YYYoungjae Yoon
Youngjae Yoon
JKJae-Eun Kim
Jae-Eun Kim
EKEunji Kim
Eunji Kim
SPSoyeon Park
Soyeon Park
IKInyeong Kang
Inyeong Kang
YKYong-Dae Kwon
Yong-Dae Kwon
Peri-implant bone loss and bone quality significantly affect the biomechanical stability and long-term success of dental implants. This study used finite element analysis to evaluate the stress distribution and deformation behavior of implants and alveolar bone according to bone loss (0–5 mm) and bone quality (normal and low). A finite element model was implemented based on a three-dimensional mandibular model. The mechanical properties of each component were assigned, and finite element analysis was performed using a static occlusal load. Results showed that progressive bone loss increased von Mises stresses in the implant fixture and surrounding bone, and low quality bone showed a significant vulnerability to stress concentration. The 2 mm bone loss model showed the maximum stress in cortical bone, and from 3 mm onwards, the stress decreased due to extensive loss of cortical bone. This may be because extensive bone loss causes the implant to lose interface with cortical bone and contact only with cancellous bone. This study confirmed that bone loss and the vulnerability of bone quality may potentially affect implant failure. Continued research is needed to suggest customized implants based on the structural vulnerability of alveolar bone.

28 November 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
EKEunji Kim
Eunji Kim
YYYoungjae Yoon
Youngjae Yoon
JKJae-Eun Kim
Jae-Eun Kim
YKYong-Dae Kwon
Yong-Dae Kwon
This study performed a finite element analysis to evaluate the biomechanical effects of implant connection geometry and bone quality (D2, D4) on stress distribution and structural stability. A mandibular model consisting of cortical and cancellous bone was generated, and implant components—including fixture, abutment, screw, and crown—were simulated. Two designs were analyzed based on Morse taper angle (11° or 15°) and the presence of an apical slot. A tightening torque of 32 N·cm and an occlusal load of 200 N were applied, with the lateral mandible constrained. The 11° taper with the non-slot design showed the highest von Mises stress (1048.81 MPa) in the fixture with D4 bone type and Tessera crown. In contrast, the 15° taper with the slot design improved stress distribution at the fixture–abutment interface, reducing fixture stress by 26.78% in D2 bone type. Localized stress near the slot was observed but did not compromise overall structural stability. Under oblique loading, stress concentrated primarily in the cortical bone, whereas D4 cancellous bone showed increased susceptibility to microdamage. Prosthetic materials demonstrated no significant differences in stress behavior. These findings suggest that connection design and bone density strongly influence biomechanical performance and should guide individualized implant selection.

31 December 2021 in Journal of dental hygiene science
Verified
Journal Article
Open access
PDF file
JKJae-Eun Kim
Jae-Eun Kim
YYYoung-Jae Yoon
Young-Jae Yoon
YKYong-Dae Kwon
Yong-Dae Kwon
SOSang-Hwan Oh
Sang-Hwan Oh
Jae-Eun Kim, Young-Jae Yoon, Yong-Dae Kwon, and Sang-Hwan Oh. J Dent Hyg Sci 2021;21:275-81. https://doi.org/10.17135/jdhs.2021.21.4.275