This paper describes the design, construction and experimental testing of a single-joint manipulator arm actuated by pneumatic artificial muscles (PAMs) for the tasks of transporting and sorting work pieces. An antagonistic muscle pair is used in a rotational sense to produce a required torque on a pulley. The concept, operating principle and elementary properties of pneumatic muscle actuators are explained. Different conceptions of the system realizations are analyzed using the morphological-matrix conceptual design framework and top-rated solution was practically realized. A simplified, control-oriented mathematical model of the manipulator arm driven by PAMs and controlled with a proportional control valve is derived. The model is then used for a controller design process. Fluidic muscles have great potential for industrial applications and assembly automation to actuate new types of robots and manipulators. Their characteristics, such as compactness, high strength, high power-to-weight ratio, inherent safety and simplicity, are worthy features for advanced manipulation systems. The experiments were carried out on a practically realized manipulator actuated by a pair of muscle actuators set into an antagonistic configuration. The setup also includes an original solution for the subsystem to add work pieces in the working space of the manipulator.
24 February 2010 in Chemical Engineering & Technology
Reforming of natural gas with steam represents the most energy-intensive part of ammonia production. An integrated numerical model for calculating composition of primary reforming products with cross-checking of outlet methane molar concentration, heat duty, maximum tube wall temperature, tube pressure drops, and approach to equilibrium was set up involving production parameters. In particular, the model was used for continuous monitoring and optimization of a steam methane reformer (SMR) catalyst in ammonia production. The calculations involve the solution of material and energy balance equations along with reaction kinetic expressions. Open source code based on Matlab file was used for modelling and calculation of various physical properties of the reacting gases. One of the main contributions is development of the rapid integrated method for data exchange between any distributed control system (DCS) and the model to accomplish continuous monitoring and optimization of SMR catalyst and reformer tubes. Integrated memory block was proposed for rapid synchronization between commercial DCS with the model solver. The developed model was verified with the industrial top-fired SMR unit in ammonia production located in Petrokemija, Croatia. Practical application of proposed solution can ensure overall energy savings of up to 3% in ammonia production.
3 February 2021 in Chemical and Biochemical Engineering Quarterly
This paper presents the development of soft sensor empirical models using support vector machine (SVM) for the continual assessment of 2,3-dimethylbutane and 2-methylpentane mole percentage as important product quality indicators in the refinery isomerisation process. During the model development, critical steps were taken, including selection and pre-processing of the industrial process data, which are broadly discussed in this paper. The SVM model results were compared with dynamic linear output error model and nonlinear Hammerstein-Wiener model. Evaluation of the developed models on independent data sets showed their reliability in the assessment of the component contents. The soft sensors are to be embedded into the process control system, and serve primarily as a replacement during the process analysersb failure and service periods.
1 June 2018 in Brazilian Journal of Chemical Engineering
In refinery plants key process variables, like contents of process stream and various fuel properties, need to be continuously monitored using adequate on-line measuring devices. Such measuring devices are often unavailable or malfunction and, hence, laboratory assays which are irregular and time consuming and therefore not suitable for process control are inevitable alternatives. This research shows a comparison of different soft sensor models developed from a small industrial data set with soft sensor models developed from data generated by a bootstrap resampling method. Soft sensors were developed applying multiple linear regression, multivariable adaptive regression splines (MARSpline) and neural networks. The purpose of the developed soft sensors is the assessing of benzene content in light reformate of a fractionation reformate plant. The best results were obtained by the neural network-based model developed on bootstrapped data.
Raman spectroscopy is a useful tool for polymorphic form-monitoring during the crystallization process. However, its application to solute concentration estimation in two-phase systems like crystallization is rare, as the Raman signal is influenced by various changing factors in the crystallization process. The development of a robust calibration model that covers all variations is complex and represents a major challenge for the implementation of Raman spectroscopy for in-line monitoring and control of the solution crystallization process. This paper describes the development of a Raman-based calibration model for estimating the solute concentration of the active pharmaceutical ingredient ceritinib. Several different calibration approaches were tested, which included both temperature and spectra of clear solutions and slurries/suspensions. It was found that the concentration of the ceritinib solution could not be accurately predicted when suspended crystals were present. To overcome this challenge, the approach was enhanced by including additional variables related to crystal size and solid concentration obtained via in-line process microscopy (chord-length distribution percentiles D10, D50 and D90) and turbidity. Partial least squares regression (PLSR) and artificial neural network (ANN) models were developed and compared based on root mean square error (RMSE). ANN models estimated the solute concentration with high accuracy, with the prediction error not exceeding 1% of the nominal solute concentration.