Milton P. Macedo

Dr. Milton P. Macedo

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 October 2006 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
ABA. Blanco
A. Blanco
NCN. Carolino
N. Carolino
CCC.M.B.A. Correia
C.M.B.A. Correia
LFLuis Fazendeiro
Luis Fazendeiro
NFNuno Ferreira
Nuno Ferreira
MMMilton P. Macedo
Milton P. Macedo
In this paper, we present experimental and simulated results from a first prototype of a positron emission tomography (PET) system based on the resistive plate chamber (RPC) technology-a gaseous particle detector developed for high energy physics. The prototype is aimed at validating the expectations, derived from simulations, of a system with submillimeter spatial image resolution and no parallax error, which may be useful for the imaging of small animals. By imaging a point-like 22Na source in the transaxial plane, an intrinsic spatial resolution of 0.52 mm FWHM was demonstrated for a system diameter of 60 mm, validating positron range simulations by other authors. A corresponding image spatial resolution of 0.51 mm FWHM was obtained using the standard algorithm of filtered backprojection (FBP) and 0.31 mm FWHM after reconstruction by an ML-EM type algorithm. An optimized complete system was simulated to evaluate sensitivity and system count rate performance for the imaging of mice, suggesting a sensitivity up to 2.1% at the center of the field of view and a peak noise equivalent count rate (NECR) up to 320 Kcps for a total activity of 88 MBq in the phantom

1 November 2004 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
ABA. Blanco
A. Blanco
NCN. Carolino
N. Carolino
CCC.M.B.A. Correia
C.M.B.A. Correia
RMR. Ferreira Marques
R. Ferreira Marques
PFPaulo Fonte
Paulo Fonte
APA. Policarpo
A. Policarpo

1 December 2004 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
ABA. Blanco
A. Blanco
NCN. Carolino
N. Carolino
CCC.M.B.A. Correia
C.M.B.A. Correia
RFR. Ferreira-Marques
R. Ferreira-Marques
PFPaulo Fonte
Paulo Fonte
APA. Policarpo
A. Policarpo

31 August 2006 in Nuclear Physics B - Proceedings Supplements
Verified
Journal Article
Closed access
ABA. Blanco
A. Blanco
NCN. Carolino
N. Carolino
CCC.M.B.A. Correia
C.M.B.A. Correia
LFLuis Fazendeiro
Luis Fazendeiro
NFNuno Ferreira
Nuno Ferreira
MMMilton P. Macedo
Milton P. Macedo

12 June 2006 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
ABA. Blanco
A. Blanco
NCN. Carolino
N. Carolino
CCC.M.B.A. Correia
C.M.B.A. Correia
LFLuis Fazendeiro
Luis Fazendeiro
NFNuno Ferreira
Nuno Ferreira
MMMilton P. Macedo
Milton P. Macedo

20 February 2025 in Signals
Verified
Journal Article
Open access
PDF file
NPNuno Pires
Nuno Pires
MMMilton P. Macedo
Milton P. Macedo
This study is part of a broader project, the Open Source Bionic Hand, which aims to develop and control, in real time, a low-cost 3D-printed bionic hand prototype using signals from the muscles of the forearm. This work is intended to implement a bimodal signal acquisition system, which uses EMG signals and Force Myography (FMG) in order to optimize the recognition of gesture intention and, consequently, the control of the bionic hand. The implementation of this bimodal EMG-FMG system will be described. It uses two different signals from BITalino EMG modules and Flexiforce™ sensors from Tekscan™. The dataset was built from thirty-six features extracted from each acquisition using two of each EMG and FMG sensors in extensor and flexor muscle groups simultaneously. The extraction of features is also depicted, as well as the subsequent use of these features to train and compare Machine Learning models in gesture recognition through MATLAB’s Classification Learner tool (v2.2.5 software). Preliminary results obtained from a dataset of three healthy volunteers show the effectiveness of this bimodal EMG/FMG system in the improvement of the efficacy on gesture recognition as it is shown, for example, for the Quadratic SVM classifier that raises from 75.00% with EMG signals to 87.96% using both signals.