Carlos Manuel B. A. Correia

Carlos Manuel B. A. Correia

Auto-generated profile, based on publicly available information

Carlos Manuel B. A. Correia

Centro de Instrumentação, Dept. de Física, Universidade de Coimbra, 3004-516 Coimbra, Portugal

Research Focus & Metrics

Academic Career Length

38Years (1989-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 October 2006 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
ABA. Blanco
A. Blanco
NCN. Carolino
N. Carolino
CCC.M.B.A. Correia
C.M.B.A. Correia
LFLuis Fazendeiro
Luis Fazendeiro
NFNuno Ferreira
Nuno Ferreira
MMMilton P. Macedo
Milton P. Macedo
In this paper, we present experimental and simulated results from a first prototype of a positron emission tomography (PET) system based on the resistive plate chamber (RPC) technology-a gaseous particle detector developed for high energy physics. The prototype is aimed at validating the expectations, derived from simulations, of a system with submillimeter spatial image resolution and no parallax error, which may be useful for the imaging of small animals. By imaging a point-like 22Na source in the transaxial plane, an intrinsic spatial resolution of 0.52 mm FWHM was demonstrated for a system diameter of 60 mm, validating positron range simulations by other authors. A corresponding image spatial resolution of 0.51 mm FWHM was obtained using the standard algorithm of filtered backprojection (FBP) and 0.31 mm FWHM after reconstruction by an ML-EM type algorithm. An optimized complete system was simulated to evaluate sensitivity and system count rate performance for the imaging of mice, suggesting a sensitivity up to 2.1% at the center of the field of view and a peak noise equivalent count rate (NECR) up to 320 Kcps for a total activity of 88 MBq in the phantom

1 November 2004 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
ABA. Blanco
A. Blanco
NCN. Carolino
N. Carolino
CCC.M.B.A. Correia
C.M.B.A. Correia
RMR. Ferreira Marques
R. Ferreira Marques
PFPaulo Fonte
Paulo Fonte
APA. Policarpo
A. Policarpo

7 May 2011 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
VAVânia Almeida
Vânia Almeida
HPH.C. Pereira
H.C. Pereira
TPTânia Pereira
Tânia Pereira
EFEdite Figueiras
Edite Figueiras
EBE. Borges
E. Borges
CCC. Correia
C. Correia

1 February 1999 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
JSJ.Bası́lio Simões
J.Bası́lio Simões
CCCarlos M.B.A Correia
Carlos M.B.A Correia

19 July 2004 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
JCJ.M. Cardoso
J.M. Cardoso
JSJ.B. Simoes
J.B. Simoes
CCC.M.B.A. Correia
C.M.B.A. Correia
ACA. Combo
A. Combo
RPR. Pereira
R. Pereira
CVC.A.F. Varandas
C.A.F. Varandas
This paper presents a new reconfigurable hardware platform which uses both digital signal processors (DSP) and field programmable gate arrays (FPGA) to attain high resolution and real-time processing in nuclear spectrometry experiments. The module was designed in order to provide a high digital pulse processing (DPP) yield with the capacity of being reconfigurable according to the experimental conditions and the desired data output. This allows unprecedented real time processing capabilities implemented in the FPGA such as pulse pileup correction through adaptive filtering and effective signal-to-noise ratio (SNR) control and optimization. The module uses a Virtex-II Pro FPGA (Xilinx) and a DSP from the TMS320C64xx family (Texas Instruments) and is implemented on a PCI board to be used in a host workstation. Special emphasis is given to the scalability of the module along with the potential capacity of being used as a portable stand-alone instrument. This reconfigurable hardware platform allows us to simultaneously benefit from the advantages of the hardware based digital spectrometers, namely, their high throughput, and of the flexibility of the software based configurations. Besides, this same platform can be used as a general purpose high-speed data acquisition and processing unit.

1 June 1996 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
PSP.C.P.S. Simoes
P.C.P.S. Simoes
JMJ.C. Martins
J.C. Martins
CCC.M.B.A. Correia
C.M.B.A. Correia