Background and Objectives: Depth perception of the human visual system in three-dimensional (3D) space plays an important role in human–computer interaction and artificial intelligence (AI) areas. It mainly employs binocular disparity and motion parallax cues. This study aims to systemically summarize the related studies about depth perception specified by these two cues. Materials and Methods: We conducted a literature investigation on related studies and summarized them from aspects like motivations, research trends, mechanisms, and interaction models of depth perception specified by these two cues. Results: Development trends show that depth perception research has gradually evolved from early studies based on a single cue to quantitative studies based on the interaction between these two cues. Mechanisms of these two cues reveal that depth perception specified by the binocular disparity cue is mainly influenced by factors like spatial variation in disparity, viewing distance, the position of visual field (or retinal image) used, and interaction with other cues; whereas that specified by the motion parallax cue is affected by head movement and retinal image motion, interaction with other cues, and the observer’s age. By integrating these two cues, several types of models for depth perception are summarized: the weak fusion (WF) model, the modified weak fusion (MWF) model, the strong fusion (SF) model, and the intrinsic constraint (IC) model. The merits and limitations of each model are analyzed and compared. Conclusions: Based on this review, a clear picture of the study on depth perception specified by binocular disparity and motion parallax cues can be seen. Open research challenges and future directions are presented. In the future, it is necessary to explore methods for easier manipulating of depth cue signals in stereoscopic images and adopting deep learning-related methods to construct models and predict depths, to meet the increasing demand of human–computer interaction in complex 3D scenarios.
Measuring the emissivity of an infrared radiant sample with high accuracy is important. Previous studies reported on the multi- or two-temperature calibration methods, which used a reference blackbody (or blackbodies) to eliminate the background radiation, and assumed that the background radiation was independent of temperature. However, in practical measurements, this assumption does not hold. To solve the above problems, this study proposes a modified two-temperature calibration method and facility. The two temperature points are set in a certain small interval based on the proposed calculation method; based on the indication of the approximation that the emissivities of the sample and the background radiations remain the same at these two temperatures, the emissivities can be calculated with measurement signals at these two temperatures, and a reference blackbody is not needed. An experimental facility was built up and three samples with emissivities around 0.100, 0.500, and 0.900 were measured in (8~14) μm. The relative expanded uncertainties were 9.6%, 4.0%, and 1.5% at 60 °C, respectively, and 8.8%, 5.8%, and 1.2% at 85 °C (k = 2), respectively. The experimental results showed consistency with the results obtained using other methods, indicating the effectiveness of the developed method. The developed method might be suitable for samples whose emissivities are temperature insensitive.
Background: With the widespread application of three-dimensional (3D) display technology, enhancing the realism of users’ experience in virtual 3D space has become important. A deep understanding of the mechanisms of human depth perception is therefore crucial. Objective: This study aims to investigate the influence of motion parallax, color, and object position cues on depth perception in 3D space. Method: Random-dot stereograms based on binocular disparity cues were constructed; three experiments were designed, varying the stimulus movement speed, color, and position; two-alternative forced-choice (2AFC) psychophysical paradigms were employed to collect participants’ responses regarding depth perception; and statistical analyses were conducted to examine the influences of these three cues on depth perception specified by binocular disparity. Results: A relatively small amount of motion parallax indicated a certain inhibitory effect on depth perception, whereas a larger amount might enhance the perceived depth. Introducing red, green, or blue color to the moving stimuli might also have a certain promoting effect. Furthermore, a significant difference in perceived depth was observed when the positions of the Test Stimulus and the Standard Stimulus differed within a trial, which might involve areas of higher-level brain function (such as visual attention). In conclusion, when multiple visual cues are present concurrently, they exhibit complex interactions that affect human depth perception.