Shufang He

Dr. Shufang He


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 May 2025 in Sensors
Verified
Journal Article
Open access
PDF file
SLShuai Li
Shuai Li
SHShufang He
Shufang He
YDYuanrui Dong
Yuanrui Dong
CDCaihong Dai
Caihong Dai
JLJinyuan Liu
Jinyuan Liu
HSHiroaki Shigemasu
Hiroaki Shigemasu
Background and Objectives: Depth perception of the human visual system in three-dimensional (3D) space plays an important role in human–computer interaction and artificial intelligence (AI) areas. It mainly employs binocular disparity and motion parallax cues. This study aims to systemically summarize the related studies about depth perception specified by these two cues. Materials and Methods: We conducted a literature investigation on related studies and summarized them from aspects like motivations, research trends, mechanisms, and interaction models of depth perception specified by these two cues. Results: Development trends show that depth perception research has gradually evolved from early studies based on a single cue to quantitative studies based on the interaction between these two cues. Mechanisms of these two cues reveal that depth perception specified by the binocular disparity cue is mainly influenced by factors like spatial variation in disparity, viewing distance, the position of visual field (or retinal image) used, and interaction with other cues; whereas that specified by the motion parallax cue is affected by head movement and retinal image motion, interaction with other cues, and the observer’s age. By integrating these two cues, several types of models for depth perception are summarized: the weak fusion (WF) model, the modified weak fusion (MWF) model, the strong fusion (SF) model, and the intrinsic constraint (IC) model. The merits and limitations of each model are analyzed and compared. Conclusions: Based on this review, a clear picture of the study on depth perception specified by binocular disparity and motion parallax cues can be seen. Open research challenges and future directions are presented. In the future, it is necessary to explore methods for easier manipulating of depth cue signals in stereoscopic images and adopting deep learning-related methods to construct models and predict depths, to meet the increasing demand of human–computer interaction in complex 3D scenarios.

5 August 2020 in Applied Optics
Verified
Journal Article
Closed access
SHShufang He
Shufang He
CDCaihong Dai
Caihong Dai
YWYanfei Wang
Yanfei Wang
JLJinyuan Liu
Jinyuan Liu
GFGuojin Feng
Guojin Feng
JWJinghui Wang
Jinghui Wang
The emissivity of the blackbody is a very important parameter in spectral radiance measurement systems. In the conventional method, the emissivity is calculated based on the isothermal model. However, the actual temperature distribution in the blackbody cavity is always nonisothermal; the emissivity calculated based on the isothermal model may not accurately present the radiation characteristic of the blackbody. In this study, the actual temperature distributions of two blackbodies (one has an extended cone shape, and the other a 65-mm diameter cylindrical shape) are measured, and the emissivities are calculated accordingly based on the nonisothermal model at a certain temperature (873 K). The results show there are different tendencies of temperature distributions in the two blackbodies. When compared with the isothermal model, the emissivities in the 873 K temperature and 2.0–20.0 µm wavelength condition are about 1.75% and 0.18% lower at the nonisothermal model for the extended cone shape and cylindrical blackbodies, respectively. To improve the emissivity, different types of apertures are customized for the two blackbodies. For the extended cone-shaped blackbody, the emissivity in the 873 K temperature and 2.0–20.0 µm wavelength condition increases by 1.12% when using a ring-shaped graphite aperture in the cavity, whereas for the cylindrical-shaped blackbody, the emissivity in the same condition increases by 0.09% when using a high-reflective aperture in front of the cavity opening. Different from previous studies, this study provides new insight in calculating and improving the effective emissivity of blackbodies by using the measured temperature in the cavity based on the nonisothermal model.

1 January 2020 in Journal of Applied Optics
Verified
Journal Article
Closed access
PDF file
SHShufang He
Shufang He
WYWang Yanfei
Wang Yanfei
DCDai Caihong
Dai Caihong
LJLiu Jinyuan
Liu Jinyuan
FGFeng Guojin
Feng Guojin
中国中国计量科学研究院光学与激光计量研究所,北京100029
中国计量科学研究院光学与激光计量研究所,北京100029
Based on the existing national primary spectral radiance measurement facilities in the ultraviolet, visible and near-infrared wave bands, the measurement range of spectral radiance was extended to 2 µm~14 µm infrared band, which could be used for the metering calibration device of infrared spectral radiance and provided technical support for infrared spectral radiometric calibration in the fields of remote sensing earth observation, climate change, target recognition, material emissivity measurement and so on. The temperature uniformity and size-of-source effect of infrared spectral radiance measurement were studied. The temperature uniformity was improved by customizing the apertures or limiting the cavity position to be used in the system; the analysis and suppression of size-of-source effect were carried out by using optical simulation method, adopting limiting apertures in the system, simplifying the optical path and so on, which effectively decreased the uncertainty of the size-of-source effect. Next, the nonlinear effect and other parameters of the system will be studied, and the total uncertainty will be evaluated.

21 September 2020 in Optics Express
Verified
Journal Article
Closed access
PDF file
SHShufang He
Shufang He
CDCaihong Dai
Caihong Dai
YWYanfei Wang
Yanfei Wang
JLJinyuan Liu
Jinyuan Liu
YXYihang Xie
Yihang Xie
JWJinghui Wang
Jinghui Wang
For a nonisothermal blackbody cavity, different reference temperatures have influence on the calculation of effective emissivity. Previous studies proposed a weighted average method which can be indicated by a priori to calculate the reference temperature. However, these studies did not mention how to define the weight function but used some arbitrary temperature or the temperature of a fixed position like the central bottom of the cavity as the reference temperature. In this study, a quantitative analysis and calculation method, which is implemented in the Monte Carlo method based optical simulation software Tracepro, is proposed to define the weight coefficients and optimize the reference temperature. To do so, in the Tracepro software, a surface source is placed in front of the cavity opening and emits radiation to the blackbody cavity. The radiation from this surface source can be absorbed or reflected many times in the cavity, and finally the incident radiation distribution in the cavity can be obtained. According to the principle of light path reversibility, the normalized incident radiation can be considered as the contribution of its position to the effective emissivity. In the experiment, the actual temperatures of two different-shaped blackbody cavities are measured with the non-contact method in 873 K temperature. By dividing the inner surface of each blackbody cavity into several regions based on the positions of the actually measured temperature points, the incident radiation from the surface source to each segmented region is calculated and normalized to the total incident radiation across all regions as its weight coefficient; the reference temperature is the sum of the weighted temperature (by multiplying each weight coefficient with its measured temperature) in each region. Different from previous studies, this study optimizes the reference temperature by considering the contribution of the whole cavity to the effective emissivity, which should be more consistent with the actual situation. Moreover, the influences of different shapes of the blackbody cavities, different radiation characteristics of the inner surface materials and different viewing conditions of the effective emissivity on the reference temperature are discussed and compared. The results suggest that the optimization of reference temperature has close link with above factors and thus should be calculated individually.

19 July 2025 in Materials
Verified
Journal Article
Open access
PDF file
SHShufang He
Shufang He
SLShuai Li
Shuai Li
CDCaihong Dai
Caihong Dai
JLJinyuan Liu
Jinyuan Liu
YWYanfei Wang
Yanfei Wang
JWJinghui Wang
Jinghui Wang
Measuring the emissivity of an infrared radiant sample with high accuracy is important. Previous studies reported on the multi- or two-temperature calibration methods, which used a reference blackbody (or blackbodies) to eliminate the background radiation, and assumed that the background radiation was independent of temperature. However, in practical measurements, this assumption does not hold. To solve the above problems, this study proposes a modified two-temperature calibration method and facility. The two temperature points are set in a certain small interval based on the proposed calculation method; based on the indication of the approximation that the emissivities of the sample and the background radiations remain the same at these two temperatures, the emissivities can be calculated with measurement signals at these two temperatures, and a reference blackbody is not needed. An experimental facility was built up and three samples with emissivities around 0.100, 0.500, and 0.900 were measured in (8~14) μm. The relative expanded uncertainties were 9.6%, 4.0%, and 1.5% at 60 °C, respectively, and 8.8%, 5.8%, and 1.2% at 85 °C (k = 2), respectively. The experimental results showed consistency with the results obtained using other methods, indicating the effectiveness of the developed method. The developed method might be suitable for samples whose emissivities are temperature insensitive.

20 February 2020 in Optics Express
Verified
Journal Article
Closed access
SHShufang He
Shufang He
CDCaihong Dai
Caihong Dai
HSHiroaki Shigemasu
Hiroaki Shigemasu
When viewing dichoptic stimuli in long time duration, visual percepts are always the alternation between the left and right eye inputs, while not the combination. This is known as binocular rivalry. An efficient coding theory reported that binocular visual inputs can be combined into binocular summation (S+) and difference (S−) channels in V1 brain area. In this study, we used specially designed stimuli as the previous study, in which monocular inputs caused ambiguous percepts, but S+ and S− channels had unambiguous percepts. We aim to investigate whether the visual percepts alter between S+ and S− channels in long time duration and whether vergence eye movements are involved in the process. To do so, the stimuli were presented in 300-s time duration in a trial, and a binocular eye tracker was used to record eye information. Participants’ real-time behavioral responses about the visual percepts and binocular information were recorded simultaneously. The results show there are perceptual flips between S+ and S− channels in both central and long time viewing conditions. More importantly, in central vision there are vergence eye movements before perceptual flips, suggesting the involvement of high level visual attention; the time of a perceptual flip from S+ is shorter than that of a flip from S−, which might be due to different involvements of visual attention, indicating a bias of feedback connection from higher brain areas for visual attention to S+ channel. Since S+ and S− dominated signals can be carried by different types of binocular neurons, our results provide new insights into high level visual attention and binocular neurons in V1 brain area by using specially designed dichoptic stimuli and eye vergence as measuring tools.