Weiguang Li

Weiguang Li


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 January 2019 in Journal of Vibration and Control
Verified
Journal Article
Closed access
ZLZhen Li
Zhen Li
WLWeiguang Li
Weiguang Li
XZXuezhi Zhao
Xuezhi Zhao
The selection of effective singular values using the singular value decomposition (SVD) method has always been a hot topic. In this paper, we found that there was a special relationship between effective singular values and feature frequency components. Theoretical derivations illustrated that each frequency component produced two adjacent nonzero singular values with one ranking another closely. Size of singular values was directly proportional to amplitude of feature frequency. The number of singular values was only related to the number of feature frequency components. For these discoveries, a novel feature frequency separation method based on SVD was proposed, through which axis orbits of large rotating machines were readily purified. The results show that the algorithm was very accurate in feature frequency extraction.

15 March 2018 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
QLQuanquan Liu
Quanquan Liu
CWChunbao Wang
Chunbao Wang
JLJianjun Long
Jianjun Long
TSTongyang Sun
Tongyang Sun
LDLihong Duan
Lihong Duan
ZWZhengzhi Wu
Zhengzhi Wu
A large amount of hemiplegic survivors are suffering from motor impairment. Ankle rehabilitation exercises act an important role in recovering patients’ walking ability after stroke. Currently, patients mainly perform ankle exercise to reobtain range of motion (ROM) and strength of the ankle joint under a therapist’s assistance by manual operation. However, therapists suffer from high work intensity, and most of the existed rehabilitation devices focus on ankle functional training and ignore the importance of neurological rehabilitation in the early hemiplegic stage. In this paper, a new robotic ankle rehabilitation platform (RARP) is proposed to assist patients in executing ankle exercise. The robotic platform consists of two three-DOF symmetric layer-stacking mechanisms, which can execute ankle internal/external rotation, dorsiflexion/plantarflexion, and inversion/eversion exercise while the rotation center of the distal zone of the robotic platform always coincides with patients’ ankle pivot center. Three exercise modes including constant-speed exercise, constant torque-impedance exercise, and awareness exercise are developed to execute ankle training corresponding to different rehabilitation stages. Experiments corresponding to these three ankle exercise modes are performed, the result demonstrated that the RARP is capable of executing ankle rehabilitation, and the novel awareness exercise mode motivates patients to proactively participate in ankle training.

5 July 2017 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
TSTongyang Sun
Tongyang Sun
HLHua Li
Hua Li
QLQuanquan Liu
Quanquan Liu
LDLihong Duan
Lihong Duan
MLMeng Li
Meng Li
YWYulong Wang
Yulong Wang
The hemiplegic rehabilitation state diagnosing performed by therapists can be biased due to their subjective experience, which may deteriorate the rehabilitation effect. In order to improve this situation, a quantitative evaluation is proposed. Though many motion analysis systems are available, they are too complicated for practical application by therapists. In this paper, a method for detecting the motion of human lower limbs including all degrees of freedom (DOFs) via the inertial sensors is proposed, which permits analyzing the patient’s motion ability. This method is applicable to arbitrary walking directions and tracks of persons under study, and its results are unbiased, as compared to therapist qualitative estimations. Using the simplified mathematical model of a human body, the rotation angles for each lower limb joint are calculated from the input signals acquired by the inertial sensors. Finally, the rotation angle versus joint displacement curves are constructed, and the estimated values of joint motion angle and motion ability are obtained. The experimental verification of the proposed motion detection and analysis method was performed, which proved that it can efficiently detect the differences between motion behaviors of disabled and healthy persons and provide a reliable quantitative evaluation of the rehabilitation state.

1 December 2015
Verified
Conference Paper
Closed access
TSTongyang Sun
Tongyang Sun
ZLZhijiang Lu
Zhijiang Lu
CWChunbao Wang
Chunbao Wang
LDLihong Duan
Lihong Duan
YSYajing Shen
Yajing Shen
ZWZhengzhi Wu
Zhengzhi Wu
It has become a trend that ankle rehabilitation robots replace traditional therapist in rehabilitation field. Many ankle rehabilitation robots have been proposed for rehabilitation training by researchers. However, most of current researches are only focusing on providing the passive training. They not only ignore the active force training for patient, but also neglect the relationship between passive training and neurological rehabilitation. In this paper, an ankle robot combining active training and passive training, subjective awareness and objective training is proposed. The ankle physiological model and mechanism of ankle rehabilitation robot are described. The control strategies of advanced training modes, passive training and active training, subjective awareness and objective training are introduced. Finally, experiments are established to testify the mechanical performance of ankle robot. Furthermore, experiment of passive training and active training is held among healthy people and the result show a good stability of the control system.

7 August 2017 in Assembly Automation
Verified
Journal Article
Closed access
QLQuanquan Liu
Quanquan Liu
CSChaoyang Shi
Chaoyang Shi
BZBo Zhang
Bo Zhang
CWChunbao Wang
Chunbao Wang
LDLihong Duan
Lihong Duan
MFMasakatsu G. Fujie
Masakatsu G. Fujie
Purpose: Paediatric congenital esophageal atresia surgery typically requires delicate and dexterous operations in a narrow and confined workspace. This study aims to develop a novel robot assisted surgical system to address these challenges. Design/methodology/approach: The proposed surgical robot consists of two symmetrical slave arms with nine degree of freedoms each. Each slave arm uses a rigid-dexterous configuration and consists of a coarse positioning manipulator and a distal fine operation manipulator. A small Selective Compliance Assembly Robot Arm (SCARA) mechanism was designed to form the main component of the coarse positioning unit, ensuring to endure large forces along the vertical direction and meet the operational demands. The fine positioning manipulator applied the novel design using flexible shafts and universal joints to achieve delicate operations while possessing a high rigidity. The corresponding kinematics has been derived and then was validated by a co-simulation that was performed based on the combined use of Adams and MATLAB with considering the real robot mass information. Experimental evaluations for the tip positioning accuracy and the ring transfer tasks have been performed. Findings: The simulation was performed to verify the correctness of the derived inverse kinematics and demonstrated the robot’s flexibility. The experimental results illustrated that the end-effector can achieve a positioning accuracy within 1.5 mm in a confined 30 × 30 × 30 mm workspace. The ring transfer task demonstrated that the surgical robot is capable of providing a solution for dexterous tissue intervention in a narrow workspace for paediatric surgery. Originality/value: A novel and compact surgical assist robot is developed to support delicate operations by using the dexterous slave arm. The slave arm consists of a SCARA mechanism to avoid experiencing overload in the vertical direction and a tool manipulator driven by flexible shafts and universal joints to provide high dexterity for operating in a narrow workspace.

1 January 2018 in Shock and Vibration
Verified
Journal Article
Open access
PDF file
ZLZhen Li
Zhen Li
WLWeiguang Li
Weiguang Li
XZXuezhi Zhao
Xuezhi Zhao
Vibration‐based diagnosis has been employed as a powerful tool in maintaining the operating efficiency and safety for large rotating machinery. However, the extraction of malfunction features is not accurate enough by using traditional vibration signal processing techniques, owing to their intrinsic shortcomings. In this paper, the relationship between effective eigenvalues and frequency components was investigated, and a new characteristic frequency separation method based on PCA (CFSM‐PCA) was proposed. Certain feature frequency could be purified by reconstructing the specified eigenvalues. Furthermore, three significant perspectives were studied via the distribution of effective eigenvalues, and theoretical derivations were subsequently illustrated. More importantly, this proposed scheme could also be used to synthesize axis orbits of larger machines. Purified curves were so explicit and the CFSM‐PCA exhibited higher efficiency than harmonic wavelet and wavelet packet.