Satoru Matsuzaki

Dr. Satoru Matsuzaki


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2021 in European Journal of Radiology
Verified
Journal Article
Open access
SMSatoru Matsuzaki
Satoru Matsuzaki
TMTakashi Moritake
Takashi Moritake
KMKoichi Morota
Koichi Morota
KNKeisuke Nagamoto
Keisuke Nagamoto
KNKoichi Nakagami
Koichi Nakagami
NKNaoki Kunugita
Naoki Kunugita
An augmented reality (AR) application to help medical staff involved in interventional radiology (IR) learn how to properly use ceiling-suspended radiation shielding screens was created, and its utility was tested from the perspective of learner motivation. The distribution of scattered radiation in an angiography room was visualized with an AR application in three settings: when a ceiling-suspended radiation shielding screen is not used (incorrect); when there is a gap between the bottom edge of the shielding screen and the patient's torso (incorrect); and when there is no gap between the bottom edge of the shielding screen and the patient's torso (correct). This AR application was used by 33 medical staff, after which an Instructional Materials Motivation Survey (IMMS) based on the John Keller's ARCS (four categories of Attention, Relevance, Confidence, and Satisfaction) Motivation Model, consisting of 36-items with responses on a 5-point (1-5) Likert scale, was conducted. The overall score was a high 4.67 ± 0.30 (mean ± standard deviation). Physician's scores tended to be lower than those of other medical staff in the categories of Attention, Relevance, and Satisfaction (not statistically significant). The AR application to learn how to properly use ceiling-suspended radiation shielding screens was highly rated from the perspective of learner motivation.

18 February 2025 in Journal of Bone and Joint Surgery
Verified
Journal Article
Open access
YHYasukazu Hijikata
Yasukazu Hijikata
KYKazuta Yamashita
Kazuta Yamashita
NHNatsuko Hatsusaka
Natsuko Hatsusaka
TNTatsuo Nagata
Tatsuo Nagata
HKHiroko Kitamura
Hiroko Kitamura
TMTakashi Moritake
Takashi Moritake
Background: The impact of radiation exposure on cataracts and hand skin cancer in orthopaedic and spine surgeons remains understudied. This study aimed to investigate the prevalence of cataracts and chronic hand inflammation in orthopaedic and spine surgeons and to assess their association with radiation exposure. Methods: A cross-sectional analysis was conducted on orthopaedic and spine surgeons attending the 38th Annual Meeting of the Neurospinal Society of Japan or the 31st Annual Meeting of the Japanese Society for the Study of Low Back Pain. Cataractous changes were categorized into none, lens micro-opacity, or cataracts and were detailed alongside the prevalence of chronic hand inflammation, which included longitudinal melanonychia and hand eczema. Participants were divided into quartiles according to hand-exposure opportunities in the operating and fluoroscopy rooms in 2022. Prevalence ratios and 95% confidence intervals (CIs) of chronic hand inflammation in the upper quartiles relative to the first quartile were calculated using modified Poisson regression adjusted for potential confounders. Results: The median work experience of the 162 participants was 23 years, and the median number of hand-exposure opportunities was 70 (interquartile range [IQR], 20 to 123) in the operating room and 20 (IQR, 0 to 60) in the fluoroscopy room. The prevalence of cataracts was 20% (32 participants), and the prevalence of cataractous changes, including lens micro-opacity, was 40% (64 participants). Chronic hand inflammation was present in 62 participants (38%), of whom 52 had longitudinal melanonychia and 23 had hand eczema. The adjusted prevalence ratios of chronic hand inflammation relative to the lowest quartile of hand-exposure opportunities in the operating room were 0.91 (0.50, 1.66) for quartile 2, 0.72 (0.41, 1.25) for quartile 3, and 1.56 (0.97, 2.50) for quartile 4. For fluoroscopy room exposure, the adjusted prevalence ratios were 2.31 (1.16, 4.58) for quartile 2, 2.03 (1.00, 4.09) for quartile 3, and 2.94 (1.51, 5.75) for quartile 4. Conclusions: This study highlighted substantial cataractous and chronic hand inflammatory changes in spine surgeons, indicating indirect and direct radiation exposure effects. Therefore, radiation safety and protective measures must be emphasized. Comparative studies with other populations and longitudinal observations are required to better understand the effects of radiation on health. Level of Evidence: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

10 January 2021 in Journal of Occupational Health
Verified
Journal Article
Open access
PDF file
KNKeisuke Nagamoto
Keisuke Nagamoto
TMTakashi Moritake
Takashi Moritake
KNKoichi Nakagami
Koichi Nakagami
KMKoichi Morota
Koichi Morota
SMSatoru Matsuzaki
Satoru Matsuzaki
NKNaoki KUNUGITA
Naoki KUNUGITA
Purpose We investigated occupational dose to the lens of the eye for physicians engaged in radiology procedures. We evaluated the potential for compliance with the new-equivalent dose limits to the lens of the eye. Further, a “multiple radiation protection” protocol was proposed according to the basic principles of occupational health, and its effectiveness was estimated. Methods Physicians engaged in radiology procedure at medical facilities in Japan were included in this study. The eye lens dose (3-mm dose equivalent: Hp(3)) for each participant was measured using a small radio-photoluminescence glass dosimeter mounted on lead glasses. Physicians were directed to procedure multiple radiation protection measures to evaluate their usefulness. Results The Hp(3) was reduced by multiple radiation protection in all physicians. In particular, the Hp(3) reduced from 207.7 to 43.2 μSv/procedure and from 21.6 to 10.2 μSv/procedure in cardiovascular internal physician and cerebrovascular physician, respectively, after the implementation of the proposed multiple radiation protection measures. The dose reduction rate of these measures was 53% (range: 37%–79%). Conclusions The radiation doses received by the eye lenses of physicians engaged in radiology procedure may exceed the dose limits to the lens of the eye if radio-protective equipment and imaging conditions are not properly controlled. However, based on the lens equivalent dose data, the implementation of “multiple radiation protection” according to the basic principles of occupational health can ensure compliance with the new-equivalent dose limits to the lens of the eye without placing an undue burden on individual physicians or medical facilities.

1 January 2021 in Heliyon
Verified
Journal Article
Open access
KNKeisuke Nagamoto
Keisuke Nagamoto
TMTakashi Moritake
Takashi Moritake
KNKoichi Nakagami
Koichi Nakagami
KMKoichi Morota
Koichi Morota
SMSatoru Matsuzaki
Satoru Matsuzaki
NKNaoki KUNUGITA
Naoki KUNUGITA
We investigated occupational dose to the lens of the eye for CT-assisting personnel for diagnostic purposes using a radio-photoluminescent glass dosimeter (RPLD) and evaluate compliance with the new equivalent dose limit for the lens of the eye (20 mSv/year). Further, we proposed the implementation of “multiple protective measures” and estimated its effect. An eye lens dosimeter clip was developed specifically to attach RPLDs inside radiation safety glasses in an L-shape. Using a total of six RPLDs attached to the radiation safety glasses, the 3-mm dose-equivalent (Hp(3)) to the lens of the eye for medical staff (n = 11; 6 intensive care physicians, 2 pediatricians, 3 radiological technologists) who assisted patients during CT scan for “diagnostic” purpose (n = 91) was measured. We evaluated the dose reduction efficiencies with radiation safety glasses and bag-valve-mask extension tube. We also estimated the protection efficiency with radiation protection curtain introduced in front of the staff's face via the phantom experiment. Without wearing radiation safety glasses, Hp(3) to the lens of the eye was greatest for intensive care physicians (0.49 mSv/procedure; allowing 40 procedures to be performed annually), followed by pediatricians (0.30 mSv/procedure; 66 procedures annually) and radiological technologists (0.28 mSv/procedure; 71 procedures annually). Use of each type of protective tools: radiation safety glasses (0.07-mm-Pb), bag-valve-mask extension tube (20 cm) and radiation protective curtain (0.25-mm-Pb), reduced Hp(3) to the lens of the eye by 51%, 31% and 61%, respectively. Intensive care physicians perform most assisted ventilations with the bag-valve-mask during “diagnostic” CT scans, and may exceed the equivalent dose limit for the lens of the eye if radiation safety glasses are not worn. If “multiple protective measures” are implemented, compliance with the equivalent dose limit for the lens of the eye should be achievable without placing significant burdens on physicians or medical institutions.

5 August 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
KNKoichi Nakagami
Koichi Nakagami
TMTakashi Moritake
Takashi Moritake
KNKeisuke Nagamoto
Keisuke Nagamoto
KMKoichi Morota
Koichi Morota
SMSatoru Matsuzaki
Satoru Matsuzaki
NKNaoki KUNUGITA
Naoki KUNUGITA
A short curtain that improves on the low versatility of existing long curtains was developed as a dedicated radiation protective device for the over-table tube fluorographic imaging units. The effect of this short curtain in preventing cataracts was then examined. First, the physician lens dose reduction rate was obtained at the position of the lens. Next, the reduction rate in the collective equivalent dose for the lens of the physician’s eye was estimated. The results showed that lens dose reduction rates with the long curtain and the short curtain were 88.9% (literature-based value) and 17.6%, respectively, higher with the long curtain. In our hospital, the reduction rate in the collective equivalent dose for the lens of the physician’s eye was 9.8% and 17.6% with a procedures mixture, using the long curtain where technically possible and no curtain in all other procedures, and the short curtain in all procedures, respectively, higher with the short curtain. Moreover, a best available for curtains raised the reduction rate in the collective equivalent dose for the lens of the physician’s eye a maximum of 25.5%. By introducing the short curtain, it can be expected to have an effect in preventing cataracts in medical staff.

SMSatoru Matsuzaki
Satoru Matsuzaki
TMTakashi Moritake
Takashi Moritake
LSLue Sun
Lue Sun
KMKoichi Morota
Koichi Morota
KNKeisuke Nagamoto
Keisuke Nagamoto
NKNaoki KUNUGITA
Naoki KUNUGITA
Interventional radiology (IR) physicians must be equipped with personal passive dosimeters and personal protective equipment (PPE); however, they are inconsistently used. Therefore, we aimed to explore practical measures to increase PPE usage and ascertain whether these measures could lead to an actual decrease in exposure doses to IR physicians. Dosimeters and PPE were visually inspected. Then, a pre-operative briefing was conducted as a direct intervention, and the use of dosimeters and PPE was verbally confirmed. Finally, the intervention effect was verified by measuring the use rates and individual exposure doses. Because of the intervention, the use rate markedly improved and was almost 100%. However, both the effective dose rate (effective dose/fluoroscopy time) and the lens equivalent dose rate (lens equivalent dose/fluoroscopy time) showed that the intervention led to a statistically significant increase in exposure (effective dose rate: p = 0.033; lens equivalent dose rate: p = 0.003). In conclusion, the proper use of dosimeters and PPE raised the radiation exposure values for IR physicians immediately after the intervention, which was hypothesized to be due to the inclusion of exposure overlooked to date and the changes in the dosimeter management method from a single- to a double-dosimeter approach.