A novel organic–inorganic eutectic phase change material (PCM) based on sodium acetate trihydrate (SAT) and polyethylene glycol (PEG) was developed to meet the needs of heat recovery and building heating. Three kinds of PEG with different molecular weights were selected to form organic–inorganic eutectic PCM with SAT. The thermal properties of three series of SAT-PEG eutectic PCM were compared based on DSC results, focusing on the impact of PEG addition on the phase change temperature and enthalpy of SAT, as well as the melting uniformity. The inhibitory effects of two nucleating agents on the supercooling of SAT-PEG eutectic PCM were systematically investigated. The effect of PEG on the crystallization behavior of SAT was studied using a metallographic microscope. To evaluate the thermal reliability of the SAT-PEG eutectic PCM, 600 cycles of melting–solidification experiments were conducted. Experimental results show that SAT can form eutectic PCMs with PEG200, PEG600, and PEG6000, respectively, with high enthalpy and excellent melting uniformity. The phase change temperature ranged from 55 °C to 60 °C and the enthalpy was as high as 250–280 kJ/kg. The results of the cooling curves show that 10 wt% tetrasodium pyrophosphate decahydrate (TPD) can reduce the supercooling degree to less than 1 °C. Significantly, all three series of SAT-PEG eutectic PCMs exhibit exceptional thermal reliability after 600 cycles of melting–solidification, with shifts in the phase change temperatures and enthalpies of less than 4%. XRD diffraction patterns showed that SAT, PEG, and TPD were physically mixed without a chemical reaction to form new substances. Microscopic images reveal that the addition of PEG preserves the original needle-shaped crystal morphology of SAT while reducing its crystal size. The rapid formation of small crystals can provide more nucleation points and expedite crystallization, thereby enhancing the heat release capabilities of the PCM.
This study presents a novel investigation into the coupled effects of ambient temperature and compressor frequency on frosting behavior and thermal performance of inverter-driven air-source heat pumps (ASHPs) under low-temperature, high-humidity conditions. Unlike previous studies that focused on single environmental parameters, this work systematically explores temperature–frequency coupling. Experiments were conducted on a 3-HP DC inverter low-ambient-temperature ASHP unit using a multi-climate simulated enthalpy difference test bench. Single-factor analysis shows that frosting is most severe at 0 °C, where the frost growth rate peaks. Regarding compressor frequency, the coefficient of performance (COP) initially increases and then decreases with frequency. The maximum COP occurs near 45 Hz, representing the optimal energy efficiency balance in this experimental system. Sensitivity analysis demonstrates that relative humidity contributes less than 5% to performance degradation at the critical 10% COP reduction point. Thus, ambient temperature and compressor frequency are the core determinants of defrosting timing. A dual-factor prediction model for the critical defrosting air-to-coil temperature difference (∆T) is developed using temperature (t) and frequency (f) as independent variables. Validation confirms that the model maintains prediction error within 10% under both single-factor and multi-factor coupling conditions. Collectively, this research quantifies the coupled effects of ambient temperature and compressor frequency on frosting performance and provides a novel theoretical framework for precise defrosting control in inverter ASHPs based on performance attenuation.