A novel organic–inorganic eutectic phase change material (PCM) based on sodium acetate trihydrate (SAT) and polyethylene glycol (PEG) was developed to meet the needs of heat recovery and building heating. Three kinds of PEG with different molecular weights were selected to form organic–inorganic eutectic PCM with SAT. The thermal properties of three series of SAT-PEG eutectic PCM were compared based on DSC results, focusing on the impact of PEG addition on the phase change temperature and enthalpy of SAT, as well as the melting uniformity. The inhibitory effects of two nucleating agents on the supercooling of SAT-PEG eutectic PCM were systematically investigated. The effect of PEG on the crystallization behavior of SAT was studied using a metallographic microscope. To evaluate the thermal reliability of the SAT-PEG eutectic PCM, 600 cycles of melting–solidification experiments were conducted. Experimental results show that SAT can form eutectic PCMs with PEG200, PEG600, and PEG6000, respectively, with high enthalpy and excellent melting uniformity. The phase change temperature ranged from 55 °C to 60 °C and the enthalpy was as high as 250–280 kJ/kg. The results of the cooling curves show that 10 wt% tetrasodium pyrophosphate decahydrate (TPD) can reduce the supercooling degree to less than 1 °C. Significantly, all three series of SAT-PEG eutectic PCMs exhibit exceptional thermal reliability after 600 cycles of melting–solidification, with shifts in the phase change temperatures and enthalpies of less than 4%. XRD diffraction patterns showed that SAT, PEG, and TPD were physically mixed without a chemical reaction to form new substances. Microscopic images reveal that the addition of PEG preserves the original needle-shaped crystal morphology of SAT while reducing its crystal size. The rapid formation of small crystals can provide more nucleation points and expedite crystallization, thereby enhancing the heat release capabilities of the PCM.
In this paper, a series of eutectic hydrated salts was obtained by mixing Na2HPO4·12H2O (DHPD) with K2HPO4·3H2O (DHPT) in different proportions. With the increase in the content of DHPT, the phase transition temperature and melting enthalpy of eutectic hydrated salts decreased gradually. Moreover, the addition of appropriate deionized water improved the thermal properties of eutectic hydrated salts. Colloidal silicon dioxide (SiO2) was selected as the support carrier to adsorb eutectic hydrated salts, and the maximum content of eutectic hydrated salts in composite PCMs was 70%. When the content of the nucleating agent (Na2SiO3·9H2O) was 5%, the supercooling degree of composite PCMs was reduced to the minimum of 1.2 °C. The SEM and FT-IR test results showed that SiO2 and eutectic hydrated salts were successfully combined, and no new substances were formed. When the content of DHPT was 3%, the phase transition temperature and melting enthalpy of composite PCMs were 26.5 °C and 145.3 J/g, respectively. The results of thermogravimetric analysis and heating–cooling cycling test proved that composite PCMs had good thermal reliability and stability. The application performance of composite PCMs in prefabricated temporary houses was investigated numerically. The results indicated that PCM panels greatly increased the Grade I thermal comfort hours and reduced energy consumption. Overall, the composite PCM has great development potential building energy conservation.
1 January 2024 in International Journal of Energy Research
In this work, it was first proposed to combine hydrated salt phase change materials (PCMs) with humidity control materials to prepare the temperature and humidity control material. The composite PCM was prepared by absorbing Na2HPO4·12H2O with colloidal silicon dioxide, and diatomite was selected as the humidity control material. The humidity performance tests found that diatomite had good moisture absorption/desorption capacity and excellent moisture buffering capacity. The supercooling degree tests showed that Na2SiO3·9H2O as nucleating agent effectively reduced the supercooling degree, and the addition of deionized water improved the water loss problem of composite PCMs. The DSC tests showed that the enthalpy and melting temperature of composite PCMs were 153.1 J/g and 28.9°C, respectively. By placing the temperature and humidity control material in different humidity, it was found that the moisture content of diatomite affected the thermal properties of composite PCMs. Diatomite could not only transfer moisture to hydrated salts but also absorb moisture from hydrated salt. The application performance tests of the temperature and humidity control material in the room model showed that it could simultaneously regulate indoor temperature and humidity. Overall, this temperature and humidity control material was more suitable for environments with high relative humidity such as greenhouses.
Accurate electricity carbon emission factors are crucial for assessing overall social carbon emissions and achieving China’s “dual carbon” goals. This paper proposes a dynamic correction model that integrates lifecycle extension, power exchange networks, and multi-time-scale decomposition to address the limitations of static carbon emission factors. The model considers factors such as power generation structure, cross-regional transmission, clean energy proportion, line losses, and non-CO2 greenhouse gas emissions, and achieves dynamic correction at quarterly and monthly scales, enhancing timeliness and regional adaptability. Results show that transmission losses, energy structure, and inter-provincial electricity exchange significantly impact carbon emission factors. For instance, in 2022, line losses in Xinjiang and Gansu raised the electricity carbon emission factor by over 0.06 kgCO2/kWh. Monthly factors exhibit significant seasonal fluctuations, with some regions showing variations of up to 105% of the annual average. Areas rich in hydropower, such as Yunnan, Sichuan, and Qinghai, experience pronounced fluctuations, highly sensitive to changes in water volume, offering more accurate reflections of carbon emission changes during electricity consumption. This study presents a refined dynamic correction method for electricity carbon emission accounting, providing theoretical support for carbon emission policy development and performance evaluation.
This study presents a novel investigation into the coupled effects of ambient temperature and compressor frequency on frosting behavior and thermal performance of inverter-driven air-source heat pumps (ASHPs) under low-temperature, high-humidity conditions. Unlike previous studies that focused on single environmental parameters, this work systematically explores temperature–frequency coupling. Experiments were conducted on a 3-HP DC inverter low-ambient-temperature ASHP unit using a multi-climate simulated enthalpy difference test bench. Single-factor analysis shows that frosting is most severe at 0 °C, where the frost growth rate peaks. Regarding compressor frequency, the coefficient of performance (COP) initially increases and then decreases with frequency. The maximum COP occurs near 45 Hz, representing the optimal energy efficiency balance in this experimental system. Sensitivity analysis demonstrates that relative humidity contributes less than 5% to performance degradation at the critical 10% COP reduction point. Thus, ambient temperature and compressor frequency are the core determinants of defrosting timing. A dual-factor prediction model for the critical defrosting air-to-coil temperature difference (∆T) is developed using temperature (t) and frequency (f) as independent variables. Validation confirms that the model maintains prediction error within 10% under both single-factor and multi-factor coupling conditions. Collectively, this research quantifies the coupled effects of ambient temperature and compressor frequency on frosting performance and provides a novel theoretical framework for precise defrosting control in inverter ASHPs based on performance attenuation.