Lixian Guo

Dr. Lixian Guo


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2023 in The Journal of the Acoustical Society of America
Verified
Journal Article
Open access
LGLixian Guo
Lixian Guo
DZDan Zhao
Dan Zhao
In this work, the output heat-driven acoustic characteristics and dynamic thermal-fluid flow fields in a looped-tube traveling-wave thermoacoustic engine (TWTAE) are numerically investigated. Emphasis is placed on optimizing acoustic power output from the TWTAE by varying its operating pressure and temperature difference across the regenerator. For this, a time domain full-scale 3-D traveling-wave TAE model is developed, and then validated by comparing with those results obtained from the experimental data available in the literature. The present results indicate that the acoustic pressure oscillations and the acoustic power are increased with increased operating pressure of the working gas. Furthermore, nonlinear acoustics and flow dynamics in the heat-driven acoustic and flow fields of the TWTAE such as vortex generation around the regenerator and Gedeon streaming are observed. Considering the comprehensive acoustic characteristics, the optimal heat-driven acoustic power output, and thermo-acoustics energy conversion efficiency are achieved, as the working air pressure is set to 0.4 MPa. Increasing the temperature difference across the regenerator can further improve the acoustic power output from the TWTAE. In summary, the present 3-D model can be used as a design tool for predicting and optimizing looped tube traveling-wave TAE performances with detailed thermos-fluid dynamics and acoustics characteristics.

1 October 2023 in The Journal of the Acoustical Society of America
Verified
Journal Article
Open access
LGLixian Guo
Lixian Guo
DZDan Zhao
Dan Zhao
The present work considers the heat-driven acoustic characteristics and dynamic thermal-fluid flow fields of a standing-wave thermoacoustic engine (SWTAE) by using sinusoidally shaped corrugated stack surfaces. 3-D numerical SWTAE models are developed and validated, aiming to examine the heat-driven acoustic effects caused by different corrugation amplitudes and wave-lengths of the sinusoidal stack surface. The results demonstrate that corrugated-shaped stack channels increase the contact area of the working gas in the stack area, and the thermos-acoustic conversion is more amplified. Compared to the SWTAE with uniform-shaped stack, the corrugated-shaped stack exhibit enhanced acoustic power output while maintaining a constant acoustic oscillation frequency. With the corrugation peak and wave-length of the sinusoidal stack are 2 and 0.2 mm, respectively, the amplitude and acoustic power of the acoustic pressure oscillations increase by 10.12% and 17.31%, respectively, in comparison with that of the conventional SWTAE. However, when the corrugation peak exceeds 0.4 mm, stronger nonlinear acoustics and flow effects are observed in the stack channels, leading to a reduction in the heat-driven acoustic power output, and thermo-acoustics energy conversion efficiency. The developed model highlights the effects of the corrugated-shaped stack on enhancing acoustic power output and thermo-acoustic conversion efficiency.

5 January 2025 in Energies
Verified
Journal Article
Open access
PDF file
LLLiaoliao Li
Liaoliao Li
YSYuze Sun
Yuze Sun
XHXinyu Huang
Xinyu Huang
LGLixian Guo
Lixian Guo
XZXinyu Zhao
Xinyu Zhao
To enhance the performance of combustors in micro thermophotovoltaic systems, this study employs numerical simulations to investigate a planar microscale combustor featuring a counter-flow flame configuration. The analysis begins with an evaluation of the effects of (1) equivalence ratio Φ and (2) inlet flow rate Vi on key thermal and combustion parameters, including the average temperature of the combustor main wall (T¯w), wall temperature non-uniformity (R¯Tw) and radiation efficiency (ηr). The findings indicate that increasing Φ causes these parameters to initially increase and subsequently decrease. Similarly, increasing the inlet flow rate leads to a monotonic decline in ηr, while the T¯w and R¯Tw exhibit a rise-then-fall trend. A comparative study between the proposed combustor and a conventional planar combustor reveals that, under identical inlet flow rate and equivalence ratio conditions, the use of the counterflow flame configuration can increase the T¯w while reducing the R¯Tw. The Nusselt number analysis shows that the counter-flow flame configuration micro-combustor achieves a larger area with positive Nusselt numbers and higher average Nusselt numbers, which highlights improved heat transfer from the fluid to the solid. Furthermore, the comparison of blow-off limits shows that the combustor with counter-flow flame configuration exhibits superior flame stability and a broader flammability range. Overall, this study provides a preliminary investigation into the use of counter-flow flame configurations in microscale combustors.