Yanli Bai

Dr. Yanli Bai


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2019 in Optik
Verified
Journal Article
Closed access
YBYanli Bai
Yanli Bai
RYRongbin Yao
Rongbin Yao
HGHaiying Gao
Haiying Gao
XDXuanju Dang
Xuanju Dang

1 May 2019 in Optik
Verified
Journal Article
Closed access
RYRongbin Yao
Rongbin Yao
YBYanli Bai
Yanli Bai
HGHaiying Gao
Haiying Gao
XWXun Wang
Xun Wang
DLDajian Liu
Dajian Liu

21 March 2025 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
YBYanli Bai
Yanli Bai
SLSongchun Li
Songchun Li
GHGuochun Huang
Guochun Huang
WLWenlong Lv
Wenlong Lv
YJYi Jiang
Yi Jiang
XQXingguo Qin
Xingguo Qin
The dilation pulse (DP) is a critical factor influencing temporal performance of magnetic focusing pulse-dilation framing camera (PDFC). As DP propagates along photocathode (PC), it not only induces variations in acceleration voltage but also results in different drift times, dilated ratios, and motion radii for electron pulse (EP) at various PC positions. This significantly affects spatiotemporal dispersion (STD) of the dynamic space charge effect (SCE) during EP drift process. To address issue, the drift step recovery diodes (DSRD) are employed to design DP. By establishing connection with the dynamic spatiotemporal characteristics of EP, the impact on dynamic SCE is analyzed. Research results indicate that the DSRD circuit can generate four DPs with peak voltages ranging from -3.508 kV to -1.819 kV, rise times between 236 ps and 288 ps, and average amplitude change rates from 22.36% to 35.0%, as well as slope change rates from 40.07% to 62.80%. When a specific DP is applied to the 50 mm PC, the transient temporal dispersion of SCE during EP drift process is inversely proportional to the electron density and drift velocity. Transient spatial dispersion is significantly influenced by EP’s radius and its ratio to the axial width, decreasing as both factors increase. When the four DPs are individually applied to PC, during EP drift process, the DP with the smallest amplitude change rate and the largest slope change rate reduces the average temporal dispersion along PC from 0.764 ps to 0.590 ps and decreases nonuniformity from 40.69% to 27.73%. The average spatial dispersion is reduced from 21.87 μm to 15.21 μm, and non-uniformity drops from 39.94% to 26.13%. These findings provide basis for analyzing and improving the STD and uniformity of dynamic SCE. Additionally, they offer research insights into integrating high-power pulse technology into ultrafast diagnostic applications.

24 May 2024 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
LLLuye Liang
Luye Liang
RYRongbin Yao
Rongbin Yao
YBYanli Bai
Yanli Bai
In the context of imaging laser radar systems (ILRS), the miniaturized streak tube (MST) serves as a crucial ultrafast diagnostic equipment, enabling the acquisition of high-quality 3-D images. The evaluation of information acquisition largely hinges on the spatial resolution (SR) performance of the MST, making it a significant parameter of interest. To enhance the system’s performance, the imaging system was designed using the dual-electrode electrostatic focusing (DEEF) technique. In this study, the relationship between the focusing electric field and imaging quality was analyzed, while the static and dynamic pattern was constructed by the CST software. To quantify the SR, the Rayleigh criterion (RC) was employed. Furthermore, the feasibility of a larger detection area and higher SR were investigated. The experimental findings revealed that the dual-focusing MST 120-mm-long has better performance, its detection area is $\Phi $ 30 mm, the deflection sensitivity is 15.05 mm/kV, and the static SR is approximately 41.84 lp/mm. Besides, the model of the voltage discrete port and the matching resistance were established, and the dynamic pattern was implemented by introducing the time-varying scanning ramp pulses. Remarkably, when the gradient of the slope pulse was 1.65 kV/ns, the dynamic SR was approximately 23.70 lp/mm, surpassing the performance of single-focusing techniques. The research conclusions not only verify the feasibility of the dual-focusing MST but also provide theoretical support to the design of the MST with high spatial performance. Furthermore, it also provides a reference method for studying the dynamic characteristics of MST by the CST.

23 October 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YBYanli Bai
Yanli Bai
YJYi Jiang
Yi Jiang
WLWenlong Lv
Wenlong Lv
SLSongchun Li
Songchun Li
GHGuochun Huang
Guochun Huang
SZSi Zhong
Si Zhong
In miniaturized streak tube (MST), the scanning electric field, while deflecting dynamic imaging, inevitably causes dynamic spatial distortion (DSD), declining dynamic spatial resolution (DSR) uniformity and hindering large-area applications. To mitigate these cases, a compensation system has been devised, aiming to reduce DSD and enhance DSR uniformity by the application of the falling edge of V-shaped high-voltage pulse (VHVP). The research results demonstrate that the VHVP, featuring a rising edge slope of 12.68 kV/ns and a falling edge slope of 15.22 kV/ns, which successfully generated by the Marx circuit combined with the LC filter. When the VHVP, in conjunction with the deflection compensation technique (DCT), was implemented in the MST, a notable reduction in DSD was achieved. Specifically, within a Φ30-mm detection area, the DSD ratio has been decreased from 35.61% to 12.09%, accompanied by 5.45% improvement in DSR uniformity at 15-mm off-axis. Furthermore, comparative analysis revealed that compared to a MST with Φ16-mm detection area, which utilized a curved cathode and spherical phosphor screen to achieve 2.31% improvement ratio, the proposed DCT demonstrated significant 17.36% improvement ratio at an 8-mm off-axis point. These findings present a universal and effective approach for the technical enhancement of MST performance.

19 December 2018 in Optik
Verified
Journal Article
Closed access
YBYanli Bai
Yanli Bai
RYRongbin Yao
Rongbin Yao
HGHaiying Gao
Haiying Gao
XWXun Wang
Xun Wang
DLDajian Liu
Dajian Liu