In this study, a novel, thorn-shaped, containing, hydrophilic, and hydrophobic surface is proposed to have a better condensate drainage characteristic and to delay the required time for frosting. By using a hydrophilic and hydrophobic mixed thorn-shaped surface created by screen printing, the design makes use of the differences in the wettability gradient to achieve rapid condensate drainage and to lengthen the time for frosting. The results of a frosting experiment indicated that the droplet adsorption and combination and discharge effect in the thorn sample were substantial. The drainage effect increased the surface renewal rate and inhibited ice layer growth on the thorn sample by 52.4% compared with that on pure copper surface. The heat transfer coefficient of the thorn sample during frosting was approximately 16.2% higher than that of pure copper surface. In addition, the defrosting results indicated that the defrosting time of the thorn sample was almost equal to that of the pure copper sample. However, large droplets were easily stagnated at the structural junction due to contact angle hysteresis after defrosting.
18 January 2024 in International Journal of Low-Carbon Technologies
To maintain strict temperature, humidity, and cleanliness requirements, the cleanrooms of high-tech semiconductor fabrication plants have heating, ventilation, and air conditioning (HVAC) systems, which require substantial amounts of energy. To reduce energy consumption, this study proposes using a wrap-around loop pulsating heat pipe (WLPHP) heat exchanger comprising a pulsating heat pipe for precooling high-temperature outdoor air to reduce relative humidity. The heat absorbed by the heat-pipe evaporator is then transferred to the condenser and released, reducing the energy required to subsequently reheat the air with an HVAC system. The experimental results reveal that the system reduces the required reheating energy and increased the moisture removal rate per unit energy consumption by an average of 24.8% and 33% compared with a typical heat exchanger. Hence, using the WLPHP heat exchanger in HVAC systems could provide large energy savings.
A novel design of an unfinned thermosyphon HPHX having a continuous closed tube loop which requires only a single charge is proposed for industrial waste heat recovery. The HPHX consists of 9×17 straight copper tubes in a staggered arrangement connected by 144 U bends. Without fins, not only are the pressure drops of the cooling air flow limited, but the cost, weight and maintenance effort can be greatly reduced. The thermal performance of this novel thermosyphon HPHX was tested with water at a filling ratio of 40%. The evaporator section is immersed in hot silicone oil, while the condenser section is cooled by air flow. The heat transfer rate (Q) reaches 6.65 kW at a heating pool temperature of 150 °C and a cooling air flow rate (F) of 1600 CMH, when the HPHX attains maximum effective thermal conductivity of 12,798 W/m-K. An ε-NTU theoretical model for single-tube thermosyphons was formulated with the boiling and film condensation modelled by empirical correlations. This model predicts the total resistance Rtot of the HPHX, which decreases with Q and F, with a total error of less than ±10%.