Luis María Franco-Grau

Luis María Franco-Grau


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 August 2025 in Metrology
Verified
Journal Article
Open access
PDF file
FMFernando Martin-Rivera
Fernando Martin-Rivera
DRDarío Rodrigo-Mallorca
Darío Rodrigo-Mallorca
LFLuis María Franco-Grau
Luis María Franco-Grau
José Vicente Cayetano Vidal VidalJosé Vicente Cayetano Vidal Vidal
José Vicente Cayetano Vidal Vidal
ASAngel Saez-Berlanga
Angel Saez-Berlanga
Iván Chulvi-MedranoIván Chulvi-Medrano
Iván Chulvi-Medrano
Background: Velocity-based training (VBT) requires precise measurement devices to monitor neuromuscular performance. PowerTrackTM is a novel optoelectronic device designed to assess movement velocity in resistance training. This study aimed to evaluate the validity and reliability of PowerTrackTM during the Smith machine back squat. Methods: Twenty experienced-trained men performed three repetitions at three submaximal loads (20, 50, and 70 kg) across two sessions. Velocity metrics—mean velocity (MV), mean propulsive velocity (MPV), and maximum velocity (Vmax)—were simultaneously recorded by PowerTrackTM and the criterion device (MuscleLabTM). Validity was assessed via ordinary least products (OLP) regression, Lin’s concordance correlation coefficient (CCC), and Bland–Altman plots. Reliability was determined using intraclass correlation coefficients (ICCs), standard error of measurement (SEM), coefficient of variation (CV), and minimum detectable change (MDC). Results: PowerTrack showed high agreement with MuscleLabTM for MPV and Vmax (slope ≈ 1.00; CCC = 0.95–0.97), while MV presented a proportional bias (slope = 0.83). ICCs ranged from 0.78 to 0.91 across loads, and SEM remained <0.09 m/s for all metrics, indicating excellent relative reliability and acceptable absolute precision. Conclusion: Despite a slight underestimation of MV at light loads, PowerTrackTM proved to be a valid and reliable device for velocity monitoring in VBT contexts.

Verified
Journal Article
Open access
PDF file
DRDarío Rodrigo-Mallorca
Darío Rodrigo-Mallorca
JMJoaquín Mollá-Sanchis
Joaquín Mollá-Sanchis
Iván Chulvi-MedranoIván Chulvi-Medrano
Iván Chulvi-Medrano
LFLuis María Franco-Grau
Luis María Franco-Grau
Objective: To evaluate changes in the isokinetic concentric moment of the knee extensors and the moment–velocity curve during the application of no BFR compared to superimposed BFR. Methods: A total of 37 physically active adults [33.73 (10.96) years; 11 females] performed three sets of isokinetic concentric knee extensions, each including three angular velocities (300°/s, 210°/s, and 120°/s; BIODEX dynamometer). BFR at 40% (BFR40) and 80% (BFR80) of the maximal pressure occlusion (MPO) were applied randomly after an equal control protocol without BFR (BFR0). Results: No significant differences were found for any interaction between the BFR condition and angular velocity (p > 0.05); 109.78 ± 32.90 vs. 71.24 ± 11.18, 116.68 ± 27.29 vs. 74.40 ± 15.11, and 113.91 ± 28.43 vs. 72.95 ± 13.76 Nm at 300°/s; 137.60 ± 35.27 vs. 88.85 ± 15.23, 135.40 ± 33.04 vs. 86.32 ± 17.38, and 132.68 ± 31.99 vs. 85.39 ± 16.25 Nm at 210°/s; 177.62 ± 41.40 vs. 114.72 ± 20.10, 166.40 ± 45.39 vs. 198.14 ± 21.80, and 162.60 ± 40.10 vs. 109.09 ± 18.90 Nm at 120°/s, for BFR0, BFR40, and BFR80, respectively. There were significant differences in the interactions by gender. Conclusions: Superimposed application of BFR at 40% MPO and 80% MPO during an isokinetic knee extension did not cause any acute change in the ability to produce maximal moment or power. The use of BFR may not generate an ergogenic effect that is sufficient to cause acute changes in force production.

12 March 2026 in Sensors
Verified
Journal Article
Open access
PDF file
FMFernando Martin-Rivera
Fernando Martin-Rivera
DRDarío Rodrigo-Mallorca
Darío Rodrigo-Mallorca
José Vicente Cayetano Vidal VidalJosé Vicente Cayetano Vidal Vidal
José Vicente Cayetano Vidal Vidal
LFLuis María Franco-Grau
Luis María Franco-Grau
ASAngel Saez-Berlanga
Angel Saez-Berlanga
Iván Chulvi-MedranoIván Chulvi-Medrano
Iván Chulvi-Medrano
Background: Accurate monitoring of eccentric phase velocity is needed to support velocity-based training (VBT), yet field-valid tools for multi-joint exercises are scarce. This study evaluated the concurrent validity and reliability of an optoelectronic device to quantify eccentric phase velocity during the Smith machine back squat. Methods: A total of 20 resistance-trained men completed two sessions and performed three repetitions at three submaximal loads (20, 50, and 70 kg). Eccentric mean velocity and peak velocity (Vmax) were recorded simultaneously using PowerTrackTM and a criterion system (MuscleLabTM). Validity was assessed using ordinary least products regression, Lin’s concordance correlation coefficient (CCC), and Bland–Altam analysis. Reliability was examined via intraclass correlation coefficients (ICC), standard error of measurement (SEM), coefficient of variation, and minimum detectable change. Results: Agreement between devices was very high for Vmax (slope ≈ 1.00; CCC = 0.95), with a small constant bias. Eccentric mean velocity showed proportional bias under higher velocity conditions, whereas overall concordance remained high (CCC = 0.95). Inter-session reliability was excellent (ICC = 0.87–0.96), with low SEM values for eccentric velocity metrics. Conclusions: PowerTrackTM can be a valid and reliable tool for monitoring eccentric phase velocity during the Smith machine back squat, with Vmax representing the most robust metric for applied eccentric VBT.