Isak Kotcioglu

Prof. Isak Kotcioglu


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2016 in Heat Transfer Engineering
Verified
Journal Article
Closed access
SCSinan Caliskan
Sinan Caliskan
MMMansur Mustafaoglu
Mansur Mustafaoglu
SBSenol Baskaya
Senol Baskaya
IKIsak Kotcioglu
Isak Kotcioglu
In this work, the effects of the impingement plate geometry, Reynolds number, jet-plate distance-to-jet diameter ratio, and the jet diameter-to-rib height ratio on the impingement jets were investigated using the Taguchi experimental design method. The heat transfer measurements over a surface with V-shaped ribs (V-SR) and convergent-divergent shaped ribs (CD-SR) by a circular impinging jet array were investigated using a thermal infrared camera. Both V-SR and CD-SR configurations, with an angle of 45°, were considered. Both projected and total Nusselt numbers were considered as performance statistics. After the data on each quality characteristic were obtained from the orthogonal arrays, a main effect analysis and analysis of variance (ANOVA) were conducted to determine the parameters that had significant effects on these quality characteristics. The L32 (21 × 43) orthogonal array was selected as an experimental plan for the four parameters. The Taguchi method was applied with an optimization process to reach the maximum heat transfer. Experimental results validated the suitability of the proposed approach. The best heat transfer performance was obtained with the V-SR arrangements.

8 October 2018 in Journal of Heat Transfer
Verified
Journal Article
Closed access
PDF file
MMMansur Mustafaoglu
Mansur Mustafaoglu
IKIsak Kotcioglu
Isak Kotcioglu
SCSinan Caliskan
Sinan Caliskan
ACAhmet Cansiz
Ahmet Cansiz

13 January 2011 in Journal of Heat Transfer
Verified
Journal Article
Closed access
PDF file
IKIsak Kotcioglu
Isak Kotcioglu
ACAhmet Cansiz
Ahmet Cansiz

31 July 2014 in Experimental Heat Transfer
Verified
Journal Article
Closed access
IKIsak Kotcioglu
Isak Kotcioglu
ACA. Cansiz
A. Cansiz
A finned convergent-divergent plate-type cross-flow heat recovery unit is manufactured and tested for efficiency analysis. Temperature and pressure drop experiments are conducted with various working conditions of the boiler, fan, preheater, and reheater of the system. Variation of Nusselt number and friction factor with Reynolds number is analyzed. Variation of effectiveness and exergy loss with number of transfer units is calculated and discussed in terms of extant literature. Experimental results indicate that the most important parameter affecting the heat transfer is winglet geometry and fluid velocity. The efficiency can be improved successfully by controlling these parameters for thermal applications.

31 March 2025 in Mathematical Modelling and Numerical Simulation with Applications
Verified
Journal Article
Open access
PDF file
MMMansur Mustafaoğlu
Mansur Mustafaoğlu
IKIsak Kotcioglu
Isak Kotcioglu
MYMuhammet Kaan Yeşilyurt
Muhammet Kaan Yeşilyurt
The analysis of blood flow in blood vessels, particularly in arteries, is a topic with important clinical applications. The blood can undergo a reduction in its viscosity under shear stress, which is called shear thinning. In this study, the effect of the shear thinning of blood is simulated using the Carreau-Yasuda model, neglecting the viscoelastic effects. The purpose of this investigation is to analyze the pulsatile blood flow in a three-dimensional model of the carotid artery and the effects of occlusion using Ansys Fluent. The results obtained in this study show that, compared to Newtonian fluids, non-Newtonian fluids exhibit significant differences in secondary flow patterns and shear flow behavior. Additionally, the axial velocity in the non-planar branch decreases with obstruction. The maximum shear stress of the walls with Newtonian fluid viscosity exhibits a significant error, and the values are lower than those of walls with non-Newtonian viscosity in most cases. In continuation of this research, vessel occlusion models with different occlusion sizes are analyzed. In the case where the outlet of the vessel is narrowed, an increase in velocity is observed in the furcation area. Although the software cannot simulate rupture, occlusion of the vessel at 80\% and 50\% of the internal diameter is analyzed.

1 January 2018 in Hittite Journal of Science and Engineering
Verified
Journal Article
Open access
PDF file
AÇA. Buğra Çolak
A. Buğra Çolak
IKIsak Kotcioglu
Isak Kotcioglu
MKMansour Nasiri Khalaji
Mansour Nasiri Khalaji
In this study, a heat exchanger system capable of working on tree-shaped three-level parallel and counter flow basis was designed and manufactured based on the branched Fractal like flow channel structure. A smiliar phylum of heat exchanger on discs. onto one surface of the lower and upper plates and both surfaces of middle plate, 156 Branched-micro channels with cylindrical sections were opened in three levels symmetrically with each other at different levels and diameters. According to the parallel and counter flow type based open circuit and closed circuit principle, the fluid enters the system at equal thermal capacity ratios from the axial or radial connection points and discharges. In the open circuit operating conditions, the heating water is in the temperature range of 35-45°C and the flow rate is 2,0-4,0 lt / min. Similarly, in the closed circuit operating conditions, the heating water is in temperature range of 45-60°C and the flow rate is 2,0-4,0 lt/ min. During the experimental work, the temperature and hydrodynamic characteristics of the system are controlled through software written in the MATLAB R2013b package program. Experimental and numerical analyzes were carried out using ANSYS-Fluent ready packet programs. In the analysis, in the increasing flow rate, positions of some external and lateral channels are determined as cause of the decrasing in level of velocity. The result, requirement of designation as the bifurcation geometry divides the mass flow rate equally for each level ol branching, is obtained. The results show that increase in level of branches is not important on the fluid channels which includes this kind (fractal) branch channel with tree-shaped. The results also show that, in the branched model heat exchanger, for opened and closed circuits, parallel flow (increasing branching levels, heating unit and cooling unit) is more efficient than the counter flow (increasing branching levels heating unit and decreasing branching level cooling unit) conditions. Keywords: Fractal Theory; Constructal Theory; MATLAB; ANSYS; Tree-Shaped Heat Exchanger; Parallel and Counter Flow; Branching Micro-Channel DOI: 10.17350/HJSE19030000117 Full Text: