Mansur Mustafaoglu

Dr. Mansur Mustafaoglu

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2016 in Heat Transfer Engineering
Verified
Journal Article
Closed access
SCSinan Caliskan
Sinan Caliskan
MMMansur Mustafaoglu
Mansur Mustafaoglu
SBSenol Baskaya
Senol Baskaya
IKIsak Kotcioglu
Isak Kotcioglu
In this work, the effects of the impingement plate geometry, Reynolds number, jet-plate distance-to-jet diameter ratio, and the jet diameter-to-rib height ratio on the impingement jets were investigated using the Taguchi experimental design method. The heat transfer measurements over a surface with V-shaped ribs (V-SR) and convergent-divergent shaped ribs (CD-SR) by a circular impinging jet array were investigated using a thermal infrared camera. Both V-SR and CD-SR configurations, with an angle of 45°, were considered. Both projected and total Nusselt numbers were considered as performance statistics. After the data on each quality characteristic were obtained from the orthogonal arrays, a main effect analysis and analysis of variance (ANOVA) were conducted to determine the parameters that had significant effects on these quality characteristics. The L32 (21 × 43) orthogonal array was selected as an experimental plan for the four parameters. The Taguchi method was applied with an optimization process to reach the maximum heat transfer. Experimental results validated the suitability of the proposed approach. The best heat transfer performance was obtained with the V-SR arrangements.

8 November 2019 in Journal of Solar Energy Engineering
Verified
Journal Article
Closed access
PDF file
AOAhmet Numan OZAKIN
Ahmet Numan OZAKIN
KYKenan Yakut
Kenan Yakut
MMMansur Mustafaoglu
Mansur Mustafaoglu
In this study, the performance of the combined system of photovoltaic-heat pump (PV/T) and effects of a newly designed evaporator on the performance of the combined system were numerically investigated. The coefficient of performance (COP) value of the heat pump and electrical efficiency of the photovoltaic system were determined considering the studies carried out at the same resource temperature. ansys Fluent software was used in the numerical analysis. According to the results, the electrical efficiency increased as expected. The maximum electrical efficiency obtained for photovoltaic system was 2.5% higher than those without cooling systems and the COP of the heat pump system was determined to be 4.75 at its maximum. The maximum exergetic efficiency of the combined system was calculated to be 55.5% at 6 m/s of refrigerant velocity.

4 September 2024 in International Communications in Heat and Mass Transfer
Verified
Journal Article
Closed access
MMMansur Mustafaoglu
Mansur Mustafaoglu
OAOkan Kaan Aksuoğlu
Okan Kaan Aksuoğlu
İKİsak Kotcioğlu
İsak Kotcioğlu
ÜGÜmit Güneş
Ümit Güneş
MYMuhammet Kaan Yeşilyurt
Muhammet Kaan Yeşilyurt
AEAli Abd Elaty
Ali Abd Elaty

11 March 2025 in Journal of the Brazilian Society of Mechanical Sciences and Engineering
Verified
Journal Article
Closed access
PDF file
MMMansur Mustafaoglu
Mansur Mustafaoglu
MYMuhammet Kaan Yeşilyurt
Muhammet Kaan Yeşilyurt
IKIsak Kotcioglu
Isak Kotcioglu
ARAbbas Razmi
Abbas Razmi

2 September 2021 in Journal of Thermal Engineering
Verified
Journal Article
Closed access
PDF file
Aliihsan KocaAliihsan Koca
Aliihsan Koca
MMMansur Mustafaoglu
Mansur Mustafaoglu
SSSoroush Sepahyar
Soroush Sepahyar
Due to the high heat transfer coefficient and compactness of a system, mili-channel-based cooling and heating techniques are greatly expected to be distributing high heat flux from the electronic devices. In terms of cooling performance, the two-phase evaporating flow of boiling flow in mini and mili-channels is more effective than the single-phase flow due to the inclusion of latent energy in the process. In this study, a numerical model was proposed to simulate the boiling heat transfer of multiphase flow in a channel using different boundary conditions in the channel surfaces. The fluid volume approach regulating the hydrodynamics of the two-phase flow was used. Source terms of the energy and mass transfer that were taken into account at the interface of liquid and vapor were included in the management equations for the conservation of energy and vapor quality. A 3D Ansys-Fluent© simulation model was developed and numerical simulations were conducted for four different boundary conditions. A mili-channel with a length of 140 mm was used. The liquid and gas phases that were used in the model were liquid water and vapor; the total mass flux at the inlet was varied at 118–126 kg/m2s. In order to realize thin film annular flow over the boiler surface, employed specific boundary conditions in the 3D simulation model were obtained by means of one dimensional Matlab© simulation code. By means of utilizing the evaluated numerical results, distribution of heat transfer coefficient, vapor quality and dimensionless temperature over the heat transfer surfaces were reported and compared to experimental results. Numerically evaluated results are in agreement with experimentally measured results. For the studies cases an average value of 23600 W/m2.K was obtained for the heat transfer coefficient.

8 October 2018 in Journal of Heat Transfer
Verified
Journal Article
Closed access
PDF file
MMMansur Mustafaoglu
Mansur Mustafaoglu
IKIsak Kotcioglu
Isak Kotcioglu
SCSinan Caliskan
Sinan Caliskan
ACAhmet Cansiz
Ahmet Cansiz