Olivia Hosie

Ms. Olivia Hosie

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2025 in Sensors
Verified
Journal Article
Open access
PDF file
OHOlivia Hosie
Olivia Hosie
MIMats Isaksson
Mats Isaksson
JMJohn McCormick
John McCormick
Oren TiroshOren Tirosh
Oren Tirosh
CHChrys Hensman
Chrys Hensman
Wearable motion capture gloves enable the precise analysis of hand and finger movements for a variety of uses, including robotic surgery, rehabilitation, and most commonly, virtual augmentation. However, many motion capture gloves restrict natural hand movement with a closed-palm design, including fabric over the palm and fingers. In order to alleviate slippage, improve comfort, reduce sizing issues, and eliminate movement restrictions, this paper presents a new low-cost data glove with an innovative open-palm and finger-free design. The new design improves usability and overall functionality by addressing the limitations of traditional closed-palm designs. It is especially beneficial in capturing movements in fields such as physical therapy and robotic surgery. The new glove incorporates resistive flex sensors (RFSs) at each finger and an inertial measurement unit (IMU) at the wrist joint to measure wrist flexion, extension, ulnar and radial deviation, and rotation. Initially the sensors were tested individually for drift, synchronisation delays, and linearity. The results show a drift of 6.60°/h in the IMU and no drift in the RFSs. There was a 0.06 s delay in the data captured by the IMU compared to the RFSs. The glove’s performance was tested with a collaborate robot testing setup. In static conditions, it was found that the IMU had a worst case error across three trials of 7.01° and a mean absolute error (MAE) averaged over three trials of 4.85°, while RFSs had a worst case error of 3.77° and a MAE of 1.25° averaged over all five RFSs used. There was no clear correlation between measurement error and speed. Overall, the new glove design proved to accurately measure joint angles.

23 April 2026
Verified
Conference Paper
Open access
JPJagannatha Charjee Pyaraka
Jagannatha Charjee Pyaraka
EVElena Marie Vella
Elena Marie Vella
JMJohn McCormick
John McCormick
OHOlivia Hosie
Olivia Hosie
MRMariadas Capsran Roshan
Mariadas Capsran Roshan
MIMats Isaksson
Mats Isaksson
Labor shortages and aging populations are straining hospital systems globally, prompting interest in humanoid robots as a viable technology solution for healthcare support. This paper presents a proof-of-concept deployment of a Unitree G1 humanoid robot using advanced SLAM with multi-modal sensors (LiDAR, depth cameras) for reliable navigation in dynamic hospital-like environments. Unlike conventional approaches that model humans solely as obstacles to avoid, our system implements human-aware navigation. Respecting proxemics, social context, and malleable spatial boundaries to treat people as collaborative partners, enabling safe, legible co-navigation in crowded wards and corridors. By demonstrating autonomous, purposeful movement for logistics and patient-support tasks, this research illustrates a pathway to augment healthcare delivery, worker support, and patient care outcomes through adaptable, human-centered robotics.

5 December 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
OHOlivia Hosie
Olivia Hosie
MIMats Isaksson
Mats Isaksson
JMJohn McCormick
John McCormick
Oren TiroshOren Tirosh
Oren Tirosh
CHChrys Hensman
Chrys Hensman
Wearable motion capture gloves enable precise analysis of hand and finger movements for a variety of uses, including robotic surgery, rehabilitation, and most commonly, virtual augmentation. However, many motion capture gloves restrict natural hand movement with a closed-palm design including fabric over the palm and fingers. In order to alleviate slippage, improve comfort, reduce sizing issues, and eliminate movement restrictions, this paper presents a new low-cost data glove with an innovative open-palm and finger-free design. The new design improves usability and overall functionality by addressing the limitations of traditional closed-palm designs. It is be especially beneficial in capturing movements in fields such as physical therapy and robotic surgery. The new glove incorporates resistive flex sensors (RFSs) at each finger and an inertial measurement unit (IMU) at the wrist joint to measure wrist flexion, extension, ulnar and radial deviation, and rotation. Initially the sensors were tested individually for drift, synchronisation delays, and linearity. Results show a drift of 6.60/h in the IMU and no drift in the RFSs. There was a 0.06 s delay in the data captured by the IMU compared to the RFSs. The glove’s performance was tested with a novel angle testing setup mounted on a collaborative robot. In static conditions, it was found that the IMU had a worst case error across three trials of 7.01 and a mean absolute error (MAE) averaged over three trials of 4.85, while RFSs had a worst case error of 3.77 and a MAE of 1.25 averaged over all five RFSs used. There was no clear correlation between measurement error and speed. Overall, the new glove design proved to accurately measure joint angles.