John McCormick

Prof. John McCormick


Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 October 2019 in Surgical Endoscopy
Verified
Journal Article
Closed access
PDF file
JHJaime Hislop
Jaime Hislop
OTOren Tirosh
Oren Tirosh
JMJohn McCormick
John McCormick
RNRomesh Nagarajah
Romesh Nagarajah
CHChris Hensman
Chris Hensman
MIMats Isaksson
Mats Isaksson

16 June 2014
Verified
Conference Paper
Open access
JMJohn McCormick
John McCormick
KVKim Vincs
Kim Vincs
SNSaeid Nahavandi
Saeid Nahavandi
DCDouglas Creighton
Douglas Creighton
SHSteph Hutchison
Steph Hutchison
For a Digital Performing Agent to be able to perform live with a human dancer, it would be useful for the agent to be able to contextualize the movement the dancer is performing and to have a suitable movement vocabulary with which to contribute to the performance. In this paper we will discuss our research into the use of Artificial Neural Networks (ANN) as a means of allowing a software agent to learn a shared vocabulary of movement from a dancer. The agent is able to use the learnt movements to form an internal representation of what the dancer is performing, allowing it to follow the dancer, generate movement sequences based on the dancer's current movement and dance independently of the dancer using a shared movement vocabulary. By combining the ANN with a Hidden Markov Model (HMM) the agent is able to recognize short full body movement phrases and respond when the dancer performs these phrases. We consider the relationship between the dancer and agent as a means of supporting the agent's learning and performance, rather than developing the agent's capability in a self-contained fashion

15 October 2021 in Sensors
Verified
Journal Article
Open access
PDF file
JHJaime Hislop
Jaime Hislop
MIMats Isaksson
Mats Isaksson
JMJohn McCormick
John McCormick
CHChris Hensman
Chris Hensman
Inertial Measurement Units (IMUs) are beneficial for motion tracking as, in contrast to most optical motion capture systems, IMU systems do not require a dedicated lab. However, IMUs are affected by electromagnetic noise and may exhibit drift over time; it is therefore common practice to compare their performance to another system of high accuracy before use. The 3-Space IMUs have only been validated in two previous studies with limited testing protocols. This study utilized an IRB 2600 industrial robot to evaluate the performance of the IMUs for the three sensor fusion methods provided in the 3-Space software. Testing consisted of programmed motion sequences including 360° rotations and linear translations of 800 mm in opposite directions for each axis at three different velocities, as well as static trials. The magnetometer was disabled to assess the accuracy of the IMUs in an environment containing electromagnetic noise. The Root-Mean-Square Error (RMSE) of the sensor orientation ranged between 0.2° and 12.5° across trials; average drift was 0.4°. The performance of the three filters was determined to be comparable. This study demonstrates that the 3-Space sensors may be utilized in an environment containing metal or electromagnetic noise with a RMSE below 10° in most cases.

1 August 2010 in Leonardo
Verified
Journal Article
Closed access
KVKim Vincs
Kim Vincs
JMJohn McCormick
John McCormick
This paper describes the work of a group of artists in Australia who used real-time motion capture and 3D stereo projection to create a large-scale performance environment in which dancers seemed to “touch” the volume. This project re-versions Suzanne Langer's 1950s philosophy of dance as “virtual force” to realize the idea of a “virtual haptics” of dance that extends the dancer's physical agency literally across and through the surrounding spatial volume. The project presents a vision of interactive dance performance that “touches” space by visualizing kinematics as intentionality and agency. In doing so, we suggest the possibility of new kinds of human-computer interfaces that emphasize touch as embodied, nuanced agency that is mediated by the subtle qualities of whole-body movement, in addition to more goal-oriented, task-based gestures such as pointing or clicking.

24 July 2020 in Surgical Endoscopy
Verified
Journal Article
Closed access
PDF file
JHJaime Hislop
Jaime Hislop
CHChris Hensman
Chris Hensman
MIMats Isaksson
Mats Isaksson
OTOren Tirosh
Oren Tirosh
JMJohn McCormick
John McCormick

9 January 2025 in Sensors
Verified
Journal Article
Open access
PDF file
OHOlivia Hosie
Olivia Hosie
MIMats Isaksson
Mats Isaksson
JMJohn McCormick
John McCormick
Oren TiroshOren Tirosh
Oren Tirosh
CHChrys Hensman
Chrys Hensman
Wearable motion capture gloves enable the precise analysis of hand and finger movements for a variety of uses, including robotic surgery, rehabilitation, and most commonly, virtual augmentation. However, many motion capture gloves restrict natural hand movement with a closed-palm design, including fabric over the palm and fingers. In order to alleviate slippage, improve comfort, reduce sizing issues, and eliminate movement restrictions, this paper presents a new low-cost data glove with an innovative open-palm and finger-free design. The new design improves usability and overall functionality by addressing the limitations of traditional closed-palm designs. It is especially beneficial in capturing movements in fields such as physical therapy and robotic surgery. The new glove incorporates resistive flex sensors (RFSs) at each finger and an inertial measurement unit (IMU) at the wrist joint to measure wrist flexion, extension, ulnar and radial deviation, and rotation. Initially the sensors were tested individually for drift, synchronisation delays, and linearity. The results show a drift of 6.60°/h in the IMU and no drift in the RFSs. There was a 0.06 s delay in the data captured by the IMU compared to the RFSs. The glove’s performance was tested with a collaborate robot testing setup. In static conditions, it was found that the IMU had a worst case error across three trials of 7.01° and a mean absolute error (MAE) averaged over three trials of 4.85°, while RFSs had a worst case error of 3.77° and a MAE of 1.25° averaged over all five RFSs used. There was no clear correlation between measurement error and speed. Overall, the new glove design proved to accurately measure joint angles.