Matthew S Rosen

Dr. Matthew S Rosen

orcid

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2018 in Nature
Verified
Journal Article
Closed access
PDF file
BZBo Zhu
Bo Zhu
JLJeremiah Z. Liu
Jeremiah Z. Liu
SCStephen F. Cauley
Stephen F. Cauley
BRBruce R. Rosen
Bruce R. Rosen
MRMatthew S Rosen
Matthew S Rosen

6 April 2018 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
OCOuri Cohen
Ouri Cohen
BZBo Zhu
Bo Zhu
MRMatthew S Rosen
Matthew S Rosen

15 October 2015 in Scientific Reports
Verified
Journal Article
Open access
MSMathieu Sarracanie
Mathieu Sarracanie
CLCristen D. LaPierre
Cristen D. LaPierre
NSNajat Salameh
Najat Salameh
DWDavid Waddington
David Waddington
TWThomas Witzel
Thomas Witzel
MRMatthew S Rosen
Matthew S Rosen
Magnetic Resonance Imaging (MRI) is unparalleled in its ability to visualize anatomical structure and function non-invasively with high spatial and temporal resolution. Yet to overcome the low sensitivity inherent in inductive detection of weakly polarized nuclear spins, the vast majority of clinical MRI scanners employ superconducting magnets producing very high magnetic fields. Commonly found at 1.5–3 tesla (T), these powerful magnets are massive and have very strict infrastructure demands that preclude operation in many environments. MRI scanners are costly to purchase, site and maintain, with the purchase price approaching $1 M per tesla (T) of magnetic field. We present here a remarkably simple, non-cryogenic approach to high-performance human MRI at ultra-low magnetic field, whereby modern under-sampling strategies are combined with fully-refocused dynamic spin control using steady-state free precession techniques. At 6.5 mT (more than 450 times lower than clinical MRI scanners) we demonstrate (2.5 × 3.5 × 8.5) mm3 imaging resolution in the living human brain using a simple, open-geometry electromagnet, with 3D image acquisition over the entire brain in 6 minutes. We contend that these practical ultra-low magnetic field implementations of MRI (<10 mT) will complement traditional MRI, providing clinically relevant images and setting new standards for affordable (<$50,000) and robust portable devices.

23 November 2020 in Nature Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
CCClarissa Z. Cooley
Clarissa Z. Cooley
PMPatrick C. McDaniel
Patrick C. McDaniel
JSJason P. Stockmann
Jason P. Stockmann
SSSai Abitha Srinivas
Sai Abitha Srinivas
SCStephen F. Cauley
Stephen F. Cauley
LWLawrence L. Wald
Lawrence L. Wald

25 August 2021 in Nature Communications
Verified
Journal Article
Open access
PDF file
MMMercy H. Mazurek
Mercy H. Mazurek
BCBradley A. Cahn
Bradley A. Cahn
MYMatthew M. Yuen
Matthew M. Yuen
APAnjali M. Prabhat
Anjali M. Prabhat
ICIsha R. Chavva
Isha R. Chavva
KSKevin N Sheth
Kevin N Sheth
Radiological examination of the brain is a critical determinant of stroke care pathways. Accessible neuroimaging is essential to detect the presence of intracerebral hemorrhage (ICH). Conventional magnetic resonance imaging (MRI) operates at high magnetic field strength (1.5–3 T), which requires an access-controlled environment, rendering MRI often inaccessible. We demonstrate the use of a low-field MRI (0.064 T) for ICH evaluation. Patients were imaged using conventional neuroimaging (non-contrast computerized tomography (CT) or 1.5/3 T MRI) and portable MRI (pMRI) at Yale New Haven Hospital from July 2018 to November 2020. Two board-certified neuroradiologists evaluated a total of 144 pMRI examinations (56 ICH, 48 acute ischemic stroke, 40 healthy controls) and one ICH imaging core lab researcher reviewed the cases of disagreement. Raters correctly detected ICH in 45 of 56 cases (80.4% sensitivity, 95%CI: [0.68–0.90]). Blood-negative cases were correctly identified in 85 of 88 cases (96.6% specificity, 95%CI: [0.90–0.99]). Manually segmented hematoma volumes and ABC/2 estimated volumes on pMRI correlate with conventional imaging volumes (ICC = 0.955, p = 1.69e-30 and ICC = 0.875, p = 1.66e-8, respectively). Hematoma volumes measured on pMRI correlate with NIH stroke scale (NIHSS) and clinical outcome (mRS) at discharge for manual and ABC/2 volumes. Low-field pMRI may be useful in bringing advanced MRI technology to resource-limited settings.

22 October 2013 in Physical Review Letters
Verified
Journal Article
Closed access
SDStephen J. DeVience
Stephen J. DeVience
RWRonald L. Walsworth
Ronald L. Walsworth
MRMatthew S Rosen
Matthew S Rosen
We introduce a broadly applicable technique to create nuclear spin singlet states in organic molecules and other many-atom systems. We employ a novel pulse sequence to produce a spin-lock induced crossing (SLIC) of the spin singlet and triplet energy levels, which enables triplet-singlet polarization transfer and singlet-state preparation. We demonstrate the utility of the SLIC method by producing a long-lived nuclear spin singlet state on two strongly coupled proton pairs in the tripeptide molecule phenylalanine-glycine-glycine dissolved in ${\mathrm{D}}_{2}\mathrm{O}$ and by using SLIC to measure the $J$ couplings, chemical shift differences, and singlet lifetimes of the proton pairs. We show that SLIC is more efficient at creating nearly equivalent nuclear spin singlet states than previous pulse sequence techniques, especially when triplet-singlet polarization transfer occurs on the same time scale as spin-lattice relaxation.