Najat Salameh

Najat Salameh

Auto-generated profile, based on publicly available information

Najat Salameh

Diagnostic Radiology Unit, Université Catholique de Louvain, Brussels, Belgium

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2008 in Gastroenterology
Verified
Journal Article
Closed access
LHLaurent Huwart
Laurent Huwart
CSChristine Sempoux
Christine Sempoux
EVEric Vicaut
Eric Vicaut
NSNajat Salameh
Najat Salameh
LALaurence Annet
Laurence Annet
BBBernard Van Beers
Bernard Van Beers

6 March 2006 in NMR in Biomedicine
Verified
Journal Article
Closed access
PDF file
LHLaurent Huwart
Laurent Huwart
FPFrank Peeters
Frank Peeters
RSRalph Sinkus
Ralph Sinkus
LALaurence Annet
Laurence Annet
NSNajat Salameh
Najat Salameh
BBBernard Van Beers
Bernard Van Beers

1 November 2007 in Radiology
Verified
Journal Article
Closed access
LHLaurent Huwart
Laurent Huwart
CSChristine Sempoux
Christine Sempoux
NSNajat Salameh
Najat Salameh
JJJacques Jamart
Jacques Jamart
LALaurence Annet
Laurence Annet
BBBernard Van Beers
Bernard Van Beers
To prospectively compare the sensitivity and specificity of magnetic resonance (MR) elastography with those of the routinely available aspartate aminotransferase-to-platelet ratio index (APRI) test for staging hepatic fibrosis in patients who have undergone liver biopsy for suspicion of chronic liver disease, with histopathologic examination as the reference standard. The study was approved by the ethics committee. All patients gave written informed consent. Eighty-eight patients (37 men, 51 women; mean age, 54.0 years +/- 13.1 [standard deviation]) who underwent liver biopsy for suspicion of chronic liver disease underwent MR elastography and APRI testing within 2 days after liver biopsy. At histopathologic examination, the fibrosis stage was assessed according to METAVIR scores (fibrosis scores F0 [no fibrosis] to F4 [cirrhosis]). MR elastography was performed by transmitting mechanical waves within the liver and measuring the small cyclic displacement of the liver spins with a phase-contrast spin-echo sequence. The performances of MR elastography and APRI testing were assessed, and the optimal cutoff values for fibrosis stage were determined with receiver operating characteristic (ROC) curve analysis. At MR elastography, areas under the ROC curves (A(z)) for elasticity and viscosity, respectively, were 0.999 and 0.863 at fibrosis scores greater than or equal to F2, 0.997 and 0.962 at scores greater than or equal to F3, and 1.000 and 0.986 at score F4. A(z) values for elasticity at MR were significantly larger than those for the APRI (0.854 at scores > or = F2, P < .001; 0.886 at scores > or = F3, P = .003; and 0.851 at score F4, P = .004). Optimal cutoff values of elasticity were 2.5 kPa for fibrosis scores greater than or equal to F2, 3.1 kPa for scores greater than or equal to F3, and 4.3 kPa for score F4. Large A(z) values for elasticity (>0.990 for scores > or = F2, > or = F3, and F4) show that MR elastography was accurate in liver fibrosis staging and superior to biochemical testing with APRIs.

15 October 2015 in Scientific Reports
Verified
Journal Article
Open access
MSMathieu Sarracanie
Mathieu Sarracanie
CLCristen D. LaPierre
Cristen D. LaPierre
NSNajat Salameh
Najat Salameh
DWDavid Waddington
David Waddington
TWThomas Witzel
Thomas Witzel
MRMatthew S Rosen
Matthew S Rosen
Magnetic Resonance Imaging (MRI) is unparalleled in its ability to visualize anatomical structure and function non-invasively with high spatial and temporal resolution. Yet to overcome the low sensitivity inherent in inductive detection of weakly polarized nuclear spins, the vast majority of clinical MRI scanners employ superconducting magnets producing very high magnetic fields. Commonly found at 1.5–3 tesla (T), these powerful magnets are massive and have very strict infrastructure demands that preclude operation in many environments. MRI scanners are costly to purchase, site and maintain, with the purchase price approaching $1 M per tesla (T) of magnetic field. We present here a remarkably simple, non-cryogenic approach to high-performance human MRI at ultra-low magnetic field, whereby modern under-sampling strategies are combined with fully-refocused dynamic spin control using steady-state free precession techniques. At 6.5 mT (more than 450 times lower than clinical MRI scanners) we demonstrate (2.5 × 3.5 × 8.5) mm3 imaging resolution in the living human brain using a simple, open-geometry electromagnet, with 3D image acquisition over the entire brain in 6 minutes. We contend that these practical ultra-low magnetic field implementations of MRI (<10 mT) will complement traditional MRI, providing clinically relevant images and setting new standards for affordable (<$50,000) and robust portable devices.

1 October 2009 in Radiology
Verified
Journal Article
Closed access
NSNajat Salameh
Najat Salameh
BLBenoît Larrat
Benoît Larrat
JAJorge Abarca-Quinones
Jorge Abarca-Quinones
SPStéphane Pallu
Stéphane Pallu
MDMylène Dorvillius
Mylène Dorvillius
BBBernard Van Beers
Bernard Van Beers
To assess the potential value of magnetic resonance (MR) elastographic imaging to help detect nonalcoholic steatohepatitis in the fatty rat liver. This study was approved by the regional ethics committee. Fifty-four rats were imaged after being fed either a standard diet, a choline-deficient diet for up to 8 weeks to induce steatohepatitis, or a 2-week orotic acid diet to induce steatosis; or were imaged 48 hours after carbon tetrachloride injection to model acute liver injury. MR elastography was performed at 7.0 T to assess viscoelastic liver parameters. Steatosis and fibrosis were quantified with morphometric and biochemical analysis. Myofibroblast activation was assessed with morphometric analysis of alpha-smooth muscle actin. Expression of transforming growth factor beta1 and procollagens 1 and 3 as markers of fibrogenesis was evaluated with real-time reverse transcription polymerase chain reaction. Inflammation was scored at histologic analysis. In rats with steatohepatitis, mean elasticity (2.24 kPa +/- 0.19 [standard deviation] vs 1.82 kPa +/- 0.22) and mean viscosity (0.86 kPa +/- 0.10 vs 0.59 kPa +/- 0.12) increased significantly (P < .005) after the 2-week orotic acid diet, while steatosis, inflammation, myofibroblast activation, and increase of other fibrogenesis markers were observed. Fibrosis appeared only after 5 weeks. In rats with steatosis, viscosity increased (0.77 kPa +/- 0.11, P < .005), elasticity remained constant. In rats with acute liver injury, elasticity (2.96 kPa +/- 0.63) and viscosity (0.85 kPa +/- 0.22) increased (P < .005), while fibrogenesis and inflammation were observed without substantial fibrosis or steatosis. At multivariate analysis in all rats, liver elasticity correlated only with myofibroblast activation (P < .001, r > 0.6). The results suggest that in nonalcoholic fatty rat liver, MR elastography may be useful in the early detection of steatohepatitis by showing increased elasticity and appearing before fibrosis development, which was linked to myofibroblast activation. http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.2523081817/-/DC1.

21 October 2013 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
PDF file
TETim R. Eichhorn
Tim R. Eichhorn
YTYuhei Takado
Yuhei Takado
NSNajat Salameh
Najat Salameh
Andrea CapozziAndrea Capozzi
Andrea Capozzi
TCTian Cheng
Tian Cheng
ACArnaud Comment
Arnaud Comment
Hyperpolarized substrates prepared via dissolution dynamic nuclear polarization have been proposed as magnetic resonance imaging (MRI) agents for cancer or cardiac failure diagnosis and therapy monitoring through the detection of metabolic impairments in vivo. The use of potentially toxic persistent radicals to hyperpolarize substrates was hitherto required. We demonstrate that by shining UV light for an hour on a frozen pure endogenous substance, namely the glucose metabolic product pyruvic acid, it is possible to generate a concentration of photo-induced radicals that is large enough to highly enhance the 13C polarization of the substance via dynamic nuclear polarization. These radicals recombine upon dissolution and a solution composed of purely endogenous products is obtained for performing in vivo metabolic hyperpolarized 13C MRI with high spatial resolution. Our method opens the way to safe and straightforward preclinical and clinical applications of hyperpolarized MRI because the filtering procedure mandatory for clinical applications and the associated pharmacological tests necessary to prevent contamination are eliminated, concurrently allowing a decrease in the delay between preparation and injection of the imaging agents for improved in vivo sensitivity.