George S Stavrakakis

Dr. George S Stavrakakis


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 January 2025 in Biomedicines
Verified
Journal Article
Open access
PDF file
SLSotirios G. Liliopoulos
Sotirios G. Liliopoulos
GSGeorge S Stavrakakis
George S Stavrakakis
Konstantinos DimasKonstantinos Dimas
Konstantinos Dimas
Background/Objectives: Cancer is a dynamic and complex disease that remains largely untreated despite major advances in oncology and treatment. In this context, we aimed here to investigate optimal control techniques in the management of tumor growth inhibition, with a particular focus on cancer chemotherapy treatment strategies. Methods: Using both linear autoregressive with exogenous inputs (ARX) and advanced non-linear tumor growth inhibition (TGI) modeling approaches, we investigated various single-agent treatment protocols, including continuous, periodic, and intermittent chemotherapy schedules. By integrating advanced mathematical modeling with optimal control theory and methods, namely the Linear Quadratic Regulator (LQR) and the “pseudo-linear” state-space equivalent representation and suboptimal control of a non-linear dynamic system known as the State-Dependent Riccati Equation (SDRE) approach, this work explores and evaluates successfully, more effective chemotherapy treatment strategies at the computer simulation level, using real preclinical data which increases the expectation to be applied in the clinical practice of oncology. Results: The integration of these methods provides insights into how different drug administration schedules may affect tumor response at the preclinical level. This work uses mathematical modeling to evaluate the efficacy of various periodic and intermittent chemotherapy treatment strategies, with a focus on optimizing drug doses while minimizing the potential side effects of chemotherapy due to the administration of less effective chemotherapeutic doses. Conclusions: The treatment scenarios tested in this study could effectively stop tumor growth or even lead to tumor regression to a negligible or near-zero size. This approach highlights the importance of computational tools for more effective treatment strategies in chemotherapy and offers a promising direction for future research and more efficient clinical applications in oncology as part of a more individualized approach.

31 May 2024 in Anticancer Research
Verified
Journal Article
Closed access
PDF file
SLSotirios G. Liliopoulos
Sotirios G. Liliopoulos
GSGeorge S Stavrakakis
George S Stavrakakis
Konstantinos DimasKonstantinos Dimas
Konstantinos Dimas
Background/Aim: Despite the advances in oncology and cancer treatment over the past decades, cancer remains one of the deadliest diseases. This study focuses on further understanding the complex nature of cancer by using mathematical tumor modeling to understand, capture as best as possible, and describe its complex dynamics under chemotherapy treatment. Materials and Methods: Focusing on autoregressive with exogenous inputs, i.e., ARX, and adaptive neuro-fuzzy inference system, i.e., ANFIS, models, this work investigates tumor growth dynamics under both single and combination anticancer agent chemotherapy treatments using chemotherapy treatment data on xenografted mice. Results: Four ARX and ANFIS models for tumor growth inhibition were developed, estimated, and evaluated, demonstrating a strong correlation with tumor weight data, with ANFIS models showing superior performance in handling the multi-agent tumor growth complexities. These findings suggest potential clinical applications of the ANFIS models through further testing. Both types of models were also tested for their prediction capabilities across different chemotherapy schedules, with accurate forecasting of tumor growth up to five days in advance. The use of adaptive prediction and sliding (moving) data window techniques allowed for continuous model updating, ensuring more robust predictive capabilities. However, long-term forecasting remains a challenge, with accuracy declining over longer prediction horizons. Conclusion: While ANFIS models showed greater reliability in predictions, the simplicity and rapid deployment of ARX models offer advantages in situations requiring immediate approximations. Future research with larger, more diverse datasets and by exploring varying model complexities is recommended to improve the models’ reliability and applicability in clinical decision-making, thereby aiding the development of personalized chemotherapy regimens.

3 February 2026 in Solar
Verified
Journal Article
Open access
PDF file
PMPanagiotis Madouros
Panagiotis Madouros
YKYiannis A. Katsigiannis
Yiannis A. Katsigiannis
Evangelos PompodakisEvangelos Pompodakis
Evangelos Pompodakis
Emmanuel KarapidakisEmmanuel Karapidakis
Emmanuel Karapidakis
GSGeorge S Stavrakakis
George S Stavrakakis
Smart microgrids are localized energy systems that integrate distributed energy resources, such as photovoltaics (PVs) and battery storage, to optimize energy use, enhance reliability, and minimize environmental impacts. This paper investigates the operation of a smart microgrid installed at the Hellenic Mediterranean University (HMU) campus in Heraklion, Crete, Greece. The system, consisting of PVs and battery storage, operates under a zero feed-in scheme, which maximizes on-site self-consumption while preventing electricity exports to the main grid. With increasing PV penetration and growing grid congestion, this scheme is an increasingly relevant strategy for microgrid operations, including university campuses. A properly sized PV–battery microgrid operating under zero feed-in operation can remain financially viable over its lifetime, while additionally it can achieve significant environmental benefits. The study performed at the HMU Campus utilizes measured hourly data of load demand, solar irradiance, and ambient temperature, while PV and battery components were modeled based on real technical specifications. The study evaluates the system using financial and environmental performance metrics, specifically net present value (NPV) and annual greenhouse gas (GHG) emission reductions, complemented by sensitivity analyses for battery technology (lead–carbon and lithium-ion), load demand levels, varying electricity prices, and projected reductions in lithium-ion battery costs over the coming years. The findings indicate that the microgrid can substantially reduce grid electricity consumption, achieving annual GHG emission reductions exceeding 600 tons of CO2. From a financial perspective, the optimal configuration consisting of a 760 kWp PV array paired with a 1250 kWh lead–carbon battery system provides a system autonomy of 46% and achieves an NPV of EUR 1.41 million over a 25-year horizon. Higher load demands and electricity prices increase the NPV of the optimal system, whereas lower load demands enhance the system’s autonomy. The anticipated reduction in lithium-ion battery costs over the next 5–10 years is expected to provide improved financial results compared to the base-case scenario. These results highlight the techno-economic viability of zero feed-in microgrids and provide valuable insights for the planning and deployment of similar systems in regions with increasing renewable penetration and grid constraints.

23 February 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
SASofia Athanasiou
Sofia Athanasiou
ESEleftheria S. Sergaki
Eleftheria S. Sergaki
APAndreas Polydorou
Andreas Polydorou
APAlexios Polydorou
Alexios Polydorou
GSGeorge S Stavrakakis
George S Stavrakakis
MZMichails Zervakis
Michails Zervakis
Purpose: The detection of where an organ starts and where it ends is achievable and, since this information can be delivered in real time, it could be quite important for several reasons. For one, by having the practical knowledge of the Wireless Endoscopic Capsule (WEC) transition through an organ’s domain, we are able to align and control the endoscopic operation with any other possible protocol, i.e., delivering some form of treatment on the spot. Another is having greater anatomical topography information per session, therefore treating the individual in detail (not “in general”). Even the fact that by gathering more accurate information for a patient by merely implementing clever software procedures is a task worth exploiting, since the problems we have to overcome in real-time processing of the capsule findings (i.e., wireless transfer of images to another unit that will apply the necessary real time computations) are still challenging. This study proposes a computer-aided detection (CAD) tool, a CNN algorithm deployed to run on field programmable gate array (FPGA), able to automatically track the capsule transitions through the entrance (gate) of esophagus, stomach, small intestine and colon, in real time. The input data are the wireless transmitted image shots of the capsule’s camera (while the endoscopy capsule is operating). Methods: We developed and evaluated three distinct multiclass classification CNNs, trained on the same dataset of total 5520 images extracted by 99 capsule videos (total 1380 frames from each organ of interest). The proposed CNNs differ in size and number of convolution filters. The confusion matrix is obtained by training each classifier and evaluating the trained model on an independent test dataset comprising 496 images extracted by 39 capsule videos, 124 from each GI organ. The test dataset was further evaluated by one endoscopist, and his findings were compared with CNN-based results. The statistically significant of predictions between the four classes of each model and the comparison between the three distinct models is evaluated by calculating the p-values and chi-square test for multi class. The comparison between the three models is carried out by calculating the macro average F1 score and Mattheus correlation coefficient (MCC). The quality of the best CNN model is estimated by calculations of sensitivity and specificity. Results: Our experimental results of independent validation demonstrate that the best of our developed models addressed this topological problem by exhibiting an overall sensitivity (96.55%) and specificity of (94.73%) in the esophagus, (81.08% sensitivity and 96.55% specificity) in the stomach, (89.65% sensitivity and 97.89% specificity) in the small intestine and (100% sensitivity and 98.94% specificity) in the colon. The average macro accuracy is 95.56%, the average macro sensitivity is 91.82%.

1 October 2025
Verified
Book Chapter
Closed access
PDF file
NSNikolaos Schetakis
Nikolaos Schetakis
KBKonstantinos Blazakis
Konstantinos Blazakis
GSGeorge S Stavrakakis
George S Stavrakakis
JSJohn E. Syllignakis
John E. Syllignakis
FKFotis Kanellos
Fotis Kanellos