Mayra Cardoso

Dr. Mayra Cardoso


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 April 2011 in Clinical Oral Implants Research
Verified
Journal Article
Closed access
PDF file
MCMayra Cardoso
Mayra Cardoso
MTMarcelo Ferreira Torres
Marcelo Ferreira Torres
ELEduardo José Veras Lourenço
Eduardo José Veras Lourenço
DTDaniel de Moraes Telles
Daniel de Moraes Telles
RRRenata Cristina Silveira Rodrigues
Renata Cristina Silveira Rodrigues
Ricardo Faria RibeiroRicardo Faria Ribeiro
Ricardo Faria Ribeiro

1 April 2016 in Ciencia & Saude Coletiva
Verified
Journal Article
Open access
MCMayra Cardoso
Mayra Cardoso
IBIvan Balducci
Ivan Balducci
DTDaniel de Moraes Telles
Daniel de Moraes Telles
ELEduardo José Veras Lourenço
Eduardo José Veras Lourenço
LJLafayette Nogueira Júnior
Lafayette Nogueira Júnior
The aim of this study was to examine the edentulism rates in Brazil and make projections for the next years. Data were collected from three national oral health surveys. The percentage of edentulous jaws was calculated. Projections were made for the years 2020, 2030 and 2040, assuming that edentulism follows a logistic function. Population projections were also performed. Annual change in proportion of edentulous jaws was -0.04% for teenagers, -0.96% for adults and 0.76% for the elderly. By 2040, edentulous jaws will be virtually zero among teenagers, 1.77% among adults and 85.96% among the elderly. Teenagers will slightly decrease in number; adults will increase and subsequently decrease; the elderly will continue to increase. In teenagers and adults, the number of edentulous jaws will decrease, being approximately 616,000 in 2040. In the elderly, it will increase alarmingly, reaching over 64 million in 2040. Edentulism is declining in Brazil among teenagers and middle-aged adults, but is still increasing and will continue to increase for the next decades among the elderly.

1 February 2015 in Journal of Applied Oral Science
Verified
Journal Article
Open access
PDF file
CCCaroline Cotes
Caroline Cotes
MCMayra Cardoso
Mayra Cardoso
RMRenata Marques de Melo
Renata Marques de Melo
LVLuiz Felipe Valandro
Luiz Felipe Valandro
Marco BottinoMarco Bottino
Marco Bottino
The purpose of this study was to assess the influence of conditioning methods and thermocycling on the bond strength between composite core and resin cement. Eighty blocks (8×8×4 mm) were prepared with core build-up composite. The cementation surface was roughened with 120-grit carbide paper and the blocks were thermocycled (5,000 cycles, between 5°C and 55°C, with a 30 s dwell time in each bath). A layer of temporary luting agent was applied. After 24 h, the layer was removed, and the blocks were divided into five groups, according to surface treatment: (NT) No treatment (control); (SP) Grinding with 120-grit carbide paper; (AC) Etching with 37% phosphoric acid; (SC) Sandblasting with 30 mm SiO2 particles, silane application; (AO) Sandblasting with 50 mm Al2O3 particles, silane application. Two composite blocks were cemented to each other (n=8) and sectioned into sticks. Half of the specimens from each block were immediately tested for microtensile bond strength (µTBS), while the other half was subjected to storage for 6 months, thermocycling (12,000 cycles, between 5°C and 55°C, with a dwell time of 30 s in each bath) and µTBS test in a mechanical testing machine. Bond strength data were analyzed by repeated measures two-way ANOVA and Tukey test (α=0.05). The µTBS was significantly affected by surface treatment (p=0.007) and thermocycling (p=0.000). Before aging, the SP group presented higher bond strength when compared to NT and AC groups, whereas all the other groups were statistically similar. After aging, all the groups were statistically similar. SP submitted to thermocycling showed lower bond strength than SP without thermocycling. Core composites should be roughened with a diamond bur before the luting process. Thermocycling tends to reduce the bond strength between composite and resin cement.

1 June 2008 in Journal of Applied Oral Science
Verified
Journal Article
Open access
PDF file
MCMayra Cardoso
Mayra Cardoso
MTMarcelo Ferreira Torres
Marcelo Ferreira Torres
MRMariana Ribeiro de Moraes Rego
Mariana Ribeiro de Moraes Rego
LSLuiz Carlos Santiago
Luiz Carlos Santiago
Marginal discrepancies may lead to cement washout and marginal leakage, damaging periodontal and pulp tissues or causing premature loss of the restoration. This study evaluated the influence of application site of provisional cement on the marginal adaptation of provisional crowns. Four different application sites of provisional cement (Temp Bond NE, Kerr Corporation) were used for cementation of provisional crowns on phantom teeth prepared for full crown restorations, performing 4 experimental groups (n=10): cement applied to all internal surfaces of the crown (CAO); cement applied to all internal surfaces of the crown, except for the occlusal surface (CA); cement applied to the cervical crown margin (CM); and cement applied to the cervical tooth margin (TM). A comparison microscope (Mitutoyo America Corporation) was used to measure the distances between the internal tangents of two circular marks, one made on the provisional crown and one made apical to the tooth preparation margin, in areas corresponding to buccal, lingual, mesial and distal surfaces. Marginal adaptation was determined before and after cementation, with 0.0001-mm accuracy. Data were analyzed statistically by ANOVA and Tukey's test at 5% significance level. Mean values of marginal opening obtained for each group were: CAO: 145 microm; CA: 67 microm; CM: 46 microm; TM: 34 microm. CA, CM and TM presented significantly lower marginal openings than CAO (p<0.05). complete filling of the crown with provisional cement, including the occlusal surface, provided greater marginal discrepancies when compared to the other methods evaluated.

12 July 2012 in International Endodontic Journal
Verified
Journal Article
Closed access
PDF file
MCMayra Cardoso
Mayra Cardoso
CMC. S. M. Martinelli
C. S. M. Martinelli
CCCláudio Antonio Talge Carvalho
Cláudio Antonio Talge Carvalho
Alexandre BorgesAlexandre Borges
Alexandre Borges
CTC. R. G. Torres
C. R. G. Torres

1 February 2016 in Journal of Periodontology
Verified
Journal Article
Closed access
MCMayra Cardoso
Mayra Cardoso
JSJorgiana Sangalli
Jorgiana Sangalli
CKCristiane Koga-Ito
Cristiane Koga-Ito
LFLeandro Lameirão Ferreira
Leandro Lameirão Ferreira
Argemiro Soares Da Silva SobrinhoArgemiro Soares Da Silva Sobrinho
Argemiro Soares Da Silva Sobrinho
LNLafayette Nogueira
Lafayette Nogueira
Background: The influence of diamond‐like carbon (DLC) films on bacterial leakage through the interface between abutments and dental implants of external hexagon (EH) and internal hexagon (IH) designs was evaluated.Methods: Film deposition was performed by plasma‐enhanced chemical vapor deposition. Sets of implants and abutments (n = 30 per group, sets of 180 implants) were divided according to connection design and treatment of the abutment base: 1) no treatment (control); 2) DLC film deposition; and 3) Ag‐DLC film deposition. Under sterile conditions, 1 μL Enterococcus faecalis was inoculated inside the implants, and abutments were tightened. The sets were tested for immediate external contamination, suspended in test tubes containing sterile culture broth, and followed for 5 days. Turbidity of the broth indicated bacterial leakage. At the end of the period, the abutments were removed and the internal content of the implants was collected with paper points and plated in Petri dishes. After 24‐hour incubation, they were assessed for bacterial viability and colony‐forming unit counting. Bacterial leakage was analyzed by χ2 and Fisher exact tests (α = 5%).Results: The percentage of bacterial leakage was 16.09% for EH implants and 80.71% for IH implants (P <0.0001). The bacterial load was higher inside IH implants (P = 0.000). The type of implant significantly influenced the results (P = 0.000), whereas the films did not (P = 0.487).Conclusion: IH implants show a higher frequency of bacterial leakage; and DLC and Ag‐DLC films do not significantly reduce the frequency of bacterial leakage and bacteria load inside the implants.