Wey H. Leong

Prof. Dr. Wey H. Leong


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2024 in Energies
Verified
Journal Article
Open access
PDF file
EKEsa Dube Kerme
Esa Dube Kerme
Alan S. FungAlan S. Fung
Alan S. Fung
WLWey H. Leong
Wey H. Leong
In this paper, a comprehensive analysis of the combined effect of major influencing parameters on heat transfer in a single U-tube BHE (sBHE) and a double U-tube BHE (dBHE) with two independent circuits was performed by using a validated numerical heat transfer model. Geometrical parameters, such as shank spacing (with maximum, average, and minimum values), borehole diameter (large, medium, and small borehole sizes), and borehole depth (shallow, average, and deep borehole depths) as well as the thermal conductivity of soil and grout, which ranges from minimum to high values, were considered. The combined impact of these parameters was included under the following four major cases: (1) the combined effect of borehole depth, borehole size, and shank spacing; (2) the combined effect of borehole depth and soil and grout thermal conductivity; (3) the combined effect of soil and grout thermal conductivity and borehole size; and (4) the combined effect of soil thermal conductivity, borehole size, and shank spacing. Each of these major cases has nine different design options for both sBHEs and dBHEs. A series of results of heat transfer per unit borehole depth were generated for all the considered various cases. With the given parameters, the BHE case that provides the highest heat transfer among the various cases of sBHEs and dBHEs were obtained.

4 March 2025 in Sustainability
Verified
Journal Article
Open access
PDF file
KTKing Tung
King Tung
RKRakesh Kumar
Rakesh Kumar
Alan S. FungAlan S. Fung
Alan S. Fung
WLWey H. Leong
Wey H. Leong
As new energy-efficient technologies emerge, space and water heating systems are continuously evolving. The latest generation of heating, ventilation, and air conditioning (HVAC) systems in Canada and other countries is shifting away from natural gas heating to cleaner electrical options, such as air-source heat pump water heaters (ASHPWH). While many studies focus on reducing space heating, research on the effectiveness of ASHPWHs in cold climates is limited. This study aims to fill that knowledge gap by analyzing the performance of ASHPWHs in typical home applications across various climates in Canada. An experimental setup was constructed, and TRNSYS modeling was employed to evaluate the techno-economic and environmental performances of these systems in comparison to existing natural gas and conventional electric water heating systems. The findings of this research indicate that ASHPWHs possess the capability to substantially decrease greenhouse gas (GHG) emissions when compared to conventional natural gas-fired water heaters. Despite this significant environmental benefit, ASHPWHs may not be the most cost-effective option due to the prevailing natural gas pricing structure. Nevertheless, there is potential for these systems to become more economically viable in the future, particularly if an appropriate level of carbon pricing mechanisms is implemented.

14 December 2024 in Processes
Verified
Journal Article
Open access
PDF file
ESElias M. Salilih
Elias M. Salilih
EKEsa Dube Kerme
Esa Dube Kerme
Alan S. FungAlan S. Fung
Alan S. Fung
WLWey H. Leong
Wey H. Leong
WLWalter Leon-Salas
Walter Leon-Salas
This study presents the development of a novel computational technique for modeling the transient heat transfer in the outer and inner regions of a single U-tube ground heat exchanger. The modeling approach couples a forward-difference numerical technique with a well-established analytical method with the aim of reducing the two-dimensional axisymmetric heat transfer problem into a one-dimensional problem, which has the benefit of reducing the computational time. Furthermore, the suggested method is numerically stable compared to a full numerical scheme, and the solution converges for a time step of up to 150 min. This is because the suggested method computes the heat transfer of the streaming fluid in the U-tube, which has a lower thermal capacitance, using the analytical technique, resulting in numerical stability at a larger time step, while the full numerical scheme has stability issues at a large time step as it computes the heat transfer of the flowing fluid in the U-tube, which also requires more computational time than the suggested method. In this model, numerical and analytical analyses are coupled with borehole wall temperature. The time-varying temperature histories of the grout material inside the borehole, the borehole wall, and the surrounding soil are presented. In addition, the time variations in the exit fluid temperature and the energy storage within the grout and the outer soil material are presented. The results show that the energy storage in the grout material reaches 62 MJ at the end of 1000 h of ground heat exchanger charging operation, while the energy storage in the surrounding soil can be as high as 7366 MJ. This study also investigates the effect of mass flow rate on the heat transfer performance of the ground heat exchanger.

10 February 2025 in Energies
Verified
Journal Article
Open access
PDF file
RMRoshaan Mudasar
Roshaan Mudasar
WLWey H. Leong
Wey H. Leong
The current research is focused on the introduction of a heat pump (HP)-assisted organic Rankine cycle (ORC), which runs on the heat extracted from a high-temperature borehole thermal energy storage (BTES). By varying different source temperatures from 40 °C to 60 °C, the HP cycle works to upgrade the heat to run the ORC. Different combinations of environmentally friendly fluids are studied in comparison to match the top and bottom cycles and to make the overall system a combined heat and power (CHP) system. A power sufficiency condition is defined to compare and identify the best working fluid combination for the HP cycle and ORC. Based on the analysis, ammonia for the HP and R1234zee for the ORC emerged to be a suitable combination among all the studied combinations. As an example, for a BTES heat source of 237 kW at the source temperature of 60 °C, the BTES–HP–ORC–district heating system with the ammonia–R1234zee pair has resulted in the HP compressor work input of 21.9 kW with the coefficient of performance (COP) of 10.9 for the HP cycle and the ORC net work output and district heating supply of 10.4 kW and 209 kW, respectively, with the thermal efficiency (η) of 4.3% for the ORC at the evaporation temperature of 65 °C. A study in terms of the greenhouse gas (GHG) emissions reveals the feasibility of the system depending on the regional GHG intensity and emission factor of electricity and natural gas.

7 March 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
EKEsa Dube Kerme
Esa Dube Kerme
Alan S. FungAlan S. Fung
Alan S. Fung
WLWey H. Leong
Wey H. Leong
In this paper, comprehensive analysis of combined effect of major influencing parameters on heat transfer in the single U-tube BHE (sBHE) and double U-tube BHE (dBHE) with two independent circuits was performed by using validated numerical heat transfer model. Geometrical parameters, such as shank spacing (with maximum, average and minimum values) and borehole diameter (large, medium and small borehole sizes) and borehole depth (shallow, average and deep borehole depths) as well as thermal conductivity of soil and grout which ranges from minimum to high value were considered. The combined impact of these parameters was included under four major cases: 1) combined effect of borehole depth, borehole size and shank spacing; 2) combined effect of borehole depth, and soil and grout thermal conductivity; 3) combined effect of soil and grout thermal conductivity and borehole size; and 4) combined effect of soil thermal conductivity, borehole size and shank spacing. Each of these major cases has nine different design options of both sBHE and dBHE. Series of results of heat transfer per unit borehole depth were generated for all the considered various cases. With the given parameters, the BHE case that provides highest heat transfer among the various cases of sBHE and dBHE were obtained.