Various researchers in the field of engineering have used porous media for many years. The present paper studies heat enhancement using two different types of porous media. In the first type, porous metal foam media was used experimentally and numerically for heat extraction. The porous medium was replaced with a porous structure using the Gyroid model and the triply periodic minimum surfaces technique in the second type. The Darcy–Brinkman model combined with the energy equation was used for the first type, whereas Navier–Stokes equations with the energy equation were implemented for the second type. The uniqueness of this approach was that it treated the Gyroid as a solid structure in the model. The two types were tested for different heat fluxes and different flow rates. A comparison between the experimental measurements and the numerical solution provided a good agreement. By comparing the performance of the two types of structure, the Gyroid structure outperformed the metal foam for heat extraction and uniformity of the temperature distribution. Despite an 18% increase in the pressure drop in the presence of the Gyroid structure, the performance evaluation criteria for the Gyroid are more significant when compared to metal foam.
In this paper, a comprehensive analysis of the combined effect of major influencing parameters on heat transfer in a single U-tube BHE (sBHE) and a double U-tube BHE (dBHE) with two independent circuits was performed by using a validated numerical heat transfer model. Geometrical parameters, such as shank spacing (with maximum, average, and minimum values), borehole diameter (large, medium, and small borehole sizes), and borehole depth (shallow, average, and deep borehole depths) as well as the thermal conductivity of soil and grout, which ranges from minimum to high values, were considered. The combined impact of these parameters was included under the following four major cases: (1) the combined effect of borehole depth, borehole size, and shank spacing; (2) the combined effect of borehole depth and soil and grout thermal conductivity; (3) the combined effect of soil and grout thermal conductivity and borehole size; and (4) the combined effect of soil thermal conductivity, borehole size, and shank spacing. Each of these major cases has nine different design options for both sBHEs and dBHEs. A series of results of heat transfer per unit borehole depth were generated for all the considered various cases. With the given parameters, the BHE case that provides the highest heat transfer among the various cases of sBHEs and dBHEs were obtained.
This study presents the development of a novel computational technique for modeling the transient heat transfer in the outer and inner regions of a single U-tube ground heat exchanger. The modeling approach couples a forward-difference numerical technique with a well-established analytical method with the aim of reducing the two-dimensional axisymmetric heat transfer problem into a one-dimensional problem, which has the benefit of reducing the computational time. Furthermore, the suggested method is numerically stable compared to a full numerical scheme, and the solution converges for a time step of up to 150 min. This is because the suggested method computes the heat transfer of the streaming fluid in the U-tube, which has a lower thermal capacitance, using the analytical technique, resulting in numerical stability at a larger time step, while the full numerical scheme has stability issues at a large time step as it computes the heat transfer of the flowing fluid in the U-tube, which also requires more computational time than the suggested method. In this model, numerical and analytical analyses are coupled with borehole wall temperature. The time-varying temperature histories of the grout material inside the borehole, the borehole wall, and the surrounding soil are presented. In addition, the time variations in the exit fluid temperature and the energy storage within the grout and the outer soil material are presented. The results show that the energy storage in the grout material reaches 62 MJ at the end of 1000 h of ground heat exchanger charging operation, while the energy storage in the surrounding soil can be as high as 7366 MJ. This study also investigates the effect of mass flow rate on the heat transfer performance of the ground heat exchanger.
This study investigates the heat transfer and fluid flow characteristics of six triply periodic minimal surface (TPMS) structures, specifically Gyroid (G3P6, G3P7, G3P8, G1P7) and Diamond (D1P7 and D3P7) configurations, using both experimental and numerical methods. Comparative analysis was conducted to evaluate the impact of adding a base to these structures on their thermal and hydraulic performance. The TPMS structures were assessed in terms of measured surface temperature, convection heat transfer coefficient, Nusselt number, overall thermal resistance, pressure drop, friction factor, and overall thermal–hydraulic performance. Results indicate that base-free structures exhibit better heat dissipation, with surface temperatures increasing by 1.2 °C (G3P6) to 5.5 °C (D3P7) when the base is added. The addition of the base reduces the convection heat transfer coefficient on average by 3.9% (G3P6) to 23% (D1P7) and increases overall thermal resistance by 3.1% (G3P6) to 28.7% (D1P7). The friction factor also rises by 6.1% (D1P7) to 47.3% (G3P6) due to the addition of the base. When the base is added, the overall thermal–hydraulic performance declines by 8.5% (G3P7) to 33.6% (D3P7), with Diamond structures experiencing a more significant reduction compared to Gyroid structures. Among the Gyroid structures, G3P6 (lower cell size and 60% porosity) demonstrated the lowest surface temperature and the highest heat dissipation capacity, while G3P8 (80% porosity) exhibited the lowest thermal performance. The Gyroid structure with larger cell size (G1P7) achieved the highest overall thermal–hydraulic performance, effectively balancing heat dissipation and fluid resistance. In contrast, when the base is integrated, the Gyroid structure with a smaller cell size and lower porosity (G3P6) showed the lowest overall thermal–hydraulic performance.
In this paper, comprehensive analysis of combined effect of major influencing parameters on heat transfer in the single U-tube BHE (sBHE) and double U-tube BHE (dBHE) with two independent circuits was performed by using validated numerical heat transfer model. Geometrical parameters, such as shank spacing (with maximum, average and minimum values) and borehole diameter (large, medium and small borehole sizes) and borehole depth (shallow, average and deep borehole depths) as well as thermal conductivity of soil and grout which ranges from minimum to high value were considered. The combined impact of these parameters was included under four major cases: 1) combined effect of borehole depth, borehole size and shank spacing; 2) combined effect of borehole depth, and soil and grout thermal conductivity; 3) combined effect of soil and grout thermal conductivity and borehole size; and 4) combined effect of soil thermal conductivity, borehole size and shank spacing. Each of these major cases has nine different design options of both sBHE and dBHE. Series of results of heat transfer per unit borehole depth were generated for all the considered various cases. With the given parameters, the BHE case that provides highest heat transfer among the various cases of sBHE and dBHE were obtained.