Douglas C Fredericks

Dr. Douglas C Fredericks

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 February 2018 in Science Translational Medicine
Verified
Journal Article
Closed access
PDF file
MCMitchell Coleman
Mitchell Coleman
JGJessica E Goetz
Jessica E Goetz
MBMarc J. Brouillette
Marc J. Brouillette
Dongrim SeolDongrim Seol
Dongrim Seol
MWMichael C. Willey
Michael C. Willey
JMJames A. Martin
James A. Martin
We tested whether inhibiting mechanically responsive articular chondrocyte mitochondria after severe traumatic injury and preventing oxidative damage represent a viable paradigm for posttraumatic osteoarthritis (PTOA) prevention. We used a porcine hock intra-articular fracture (IAF) model well suited to human-like surgical techniques and with excellent anatomic similarities to human ankles. After IAF, amobarbital or N-acetylcysteine (NAC) was injected to inhibit chondrocyte electron transport or downstream oxidative stress, respectively. Effects were confirmed via spectrophotometric enzyme assays or glutathione/glutathione disulfide assays and immunohistochemical measures of oxidative stress. Amobarbital or NAC delivered after IAF provided substantial protection against PTOA at 6 months, including maintenance of proteoglycan content, decreased histological disease scores, and normalized chondrocyte metabolic function. These data support the therapeutic potential of targeting chondrocyte metabolism after injury and suggest a strong role for mitochondria in mediating PTOA.

15 October 2015 in Spine
Verified
Journal Article
Closed access
AGAnup A. Gandhi
Anup A. Gandhi
SKSwathi Kode
Swathi Kode
NDNicole A. DeVries
Nicole A. DeVries
NGNicole M. Grosland
Nicole M. Grosland
JSJoseph D. Smucker
Joseph D. Smucker
DFDouglas C Fredericks
Douglas C Fredericks
Study Design. A biomechanical study comparing arthroplasty with fusion using human cadaveric C2–T1 spines. Objective. To compare the kinematics of the cervical spine after arthroplasty and fusion using single level, 2 level and hybrid constructs. Summary of Background Data. Previous studies have shown that spinal levels adjacent to a fusion experience increased motion and higher stress which may lead to adjacent segment disc degeneration. Cervical arthroplasty achieves similar decompression but preserves the motion at the operated level, potentially decreasing the occurrence of adjacent segment disc degeneration. Methods. 11 specimens (C2–T1) were divided into 2 groups (BRYAN and PRESTIGE LP). The specimens were tested in the following order; intact, single level total disc replacement (TDR) at C5–C6, 2-level TDR at C5–C6–C7, fusion at C5–C6 and TDR at C6–C7 (Hybrid construct), and lastly a 2-level fusion. The intact specimens were tested up to a moment of 2.0 Nm. After each surgical intervention, the specimens were loaded until the primary motion (C2–T1) matched the motion of the respective intact state (hybrid control). Results. An arthroplasty preserved motion at the implanted level and maintained normal motion at the nonoperative levels. Arthrodesis resulted in a significant decrease in motion at the fused level and an increase in motion at the unfused levels. In the hybrid construct, the TDR adjacent to fusion preserved motion at the arthroplasty level, thereby reducing the demand on the other levels. Conclusion. Cervical disc arthroplasty with both the BRYAN and PRESTIGE LP discs not only preserved the motion at the operated level, but also maintained the normal motion at the adjacent levels. Under simulated physiologic loading, the motion patterns of the spine with the BRYAN or PRESTIGE LP disc were very similar and were closer than fusion to the intact motion pattern. An adjacent segment disc replacement is biomechanically favorable to a fusion in the presence of a pre-existing fusion. Level of Evidence: N/A

15 January 2007 in Spine
Verified
Journal Article
Closed access
DFDouglas C Fredericks
Douglas C Fredericks
JSJoseph Smucker
Joseph Smucker
EPEmily B. Bs Petersen
Emily B. Bs Petersen
JBJohn A. Ba Bobst
John A. Ba Bobst
JGJean C. Gan
Jean C. Gan
PGPaul Glazer
Paul Glazer
Study Design. An in vivo model was used to determine levels of mRNA expression in response to direct current (DC) electrical stimulation in a rabbit posterolateral fusion model. Objectives. This study tested the possibility that DC stimulation at the surgery site would increase expression of genes related to bone formation relative to expression in autograft alone. Summary of Background Data. DC electrical stimulation as an adjunct treatment in spinal surgery has shown increased fusion rates when compared with autograft alone, yet the biology of such treatment is not fully understood. Methods. Thirty New Zealand White rabbits were entered into the study. A posterolateral, intertransverse process fusion was performed bilaterally at L4–L5, with autogenous bone graft. An implantable DC stimulator was placed across the decorticated transverse processes before placement of autograft. Animals were killed at 3, 7, 14, 21, and 28 days. mRNA levels of BMP-2, 4, 6, 7, VEGF, FGF-2, TGF-β, ALK-2, and ALK-3 were evaluated with real-time RT-PCR. Results. mRNA expression was significantly higher in the DC stimulated animals versus the control animals for several of the genes studied. In particular, levels of mRNA were elevated for BMP-2, BMP-6, and BMP-7. Conclusions. This study shows for the first time that DC stimulation results in a sustained increase of multiple osteogenic genes, suggesting that the biologic mechanism for the DC-induced increase in the rate and extent of bone formation observed clinically may be mediated by the up-regulation of these osteoinductive factors.

1 July 2003 in Journal of Pediatric Orthopaedics
Verified
Journal Article
Closed access
DFDouglas C Fredericks
Douglas C Fredericks
DPDebra J. Piehl
Debra J. Piehl
JBJoy T. Baker
Joy T. Baker
JAJoan Abbott
Joan Abbott
JNJames V. Nepola
James V. Nepola
The purpose of this study was to determine whether exposure to pulsed electromagnetic field (PEMF) would shorten the healing time of regenerate bone in a rabbit tibial distraction model. Beginning 1 day after surgery, mid-shaft tibial osteotomies, stabilized with external fixators, were distracted 0.25 mm twice daily for 21 days and received either no exposure (sham control) or 1 hour per day exposure to low-amplitude, low-frequency PEMF. Tibiae were tested for torsional strength after 9, 16, and 23 days post-distraction. PEMF-treated tibiae were significantly stronger than shams at all three time points. By 16 days post-distraction, the PEMF group had achieved biomechanical strength essentially equivalent to intact bone. Shams did not achieve normal biomechanical strength even after 23 days post-distraction. In this tibial distraction model, short daily PEMF exposures accelerated consolidation of regenerate bone. Clinical usefulness awaits testing.

1 June 2018 in Journal of Pain Research
Verified
Journal Article
Open access
PDF file
CRChandan G Reddy
Chandan G Reddy
JMJohn W Miller
John W Miller
KAKingsley Abode-Iyamah
Kingsley Abode-Iyamah
SSSina Safayi
Sina Safayi
SWSaul Wilson
Saul Wilson
TBTimothy J Brennan
Timothy J Brennan
Background: It is becoming increasingly important to understand the mechanisms of spinal cord stimulation (SCS) in alleviating neuropathic pain as novel stimulation paradigms arise. Purpose: Additionally, the small anatomic scale of current SCS animal models is a barrier to more translational research. Methods: Using chronic constriction injury (CCI) of the common peroneal nerve (CPN) in sheep (ovine), we have created a chronic model of neuropathic pain that avoids motor deficits present in prior large animal models. This large animal model has allowed us to implant clinical grade SCS hardware, which enables both acute and chronic testing using von Frey filament thresholds and gait analysis. Furthermore, the larger anatomic scale of the sheep allows for simultaneous single-unit recordings from the dorsal horn and SCS with minimal electrical artifact. Results: Detectable tactile hypersensitivity occurred 21 days after nerve injury, with preliminary indications that chronic SCS may reverse it in the painful limb. Gait analysis revealed no hoof drop in the CCI model. Single neurons were identified and discriminated in the dorsal horn, and their activity was modulated via SCS. Unlike previous large animal models that employed a complete transection of the nerve, no motor deficit was observed in the sheep with CCI. Conclusion: To our knowledge, this is the first reported large animal model of chronic neuropathic pain which facilitates the study of both acute and chronic SCS using complementary behavioral and electrophysiologic measures. As demonstrated by our successful establishment of these techniques, an ovine model of neuropathic pain is suitable for testing the mechanisms of SCS.

1 February 2013 in Spine
Verified
Journal Article
Closed access
RIRyan M. Ilgenfritz
Ryan M. Ilgenfritz
AGAnup A. Gandhi
Anup A. Gandhi
DFDouglas C Fredericks
Douglas C Fredericks
NGNicole M. Grosland
Nicole M. Grosland
JSJoseph D. Smucker
Joseph D. Smucker
Radiographical and biomechanical analyses. To determine the applicability of C7 laminar screw fixation using radiographical and biomechanical analysis. The unique anatomy of C7 creates a challenge during instrumentation at the caudal aspect of the cervical spine and cervicothoracic junction. The C7 lateral mass is often smaller, resulting in increased difficulty for pedicle screw placement. The use of crossing laminar screw fixation is common in the upper cervical and thoracic spine; its use at the C7 level, however, has only recently appeared in the literature. Radiographical: Computed tomographic scans from 72 patients were used to measure laminar thickness, spinolaminar angle, and length (i.e., from the spinolaminar junction to the contralateral lamina-lateral mass junction) for each C7 vertebrae. Biomechanical: The C2 and C7 vertebrae from 13 cadaveric cervical spines were obtained, scanned using pQCT (Stratec Electronics, Pforzheim, Germany) for bone mineral density, and then instrumented in the following manner: (1) bilateral crossing intralaminar screws in C2, (2) bilateral crossing intralaminar screws in C7, and (3) bilateral pedicle screws in each C7 specimen after completion of laminar screw biomechanical testing. Each specimen was cyclically loaded for 5000 cycles after which axial screw pullout tests were performed. Radiographical: Mean laminar thickness and length were 5.67 ± 1.00 mm and 25.49 ± 2.73 mm, respectively. Biomechanical: The mean load to failure was 610.3 ± 251 N for C7 laminar screws, 666.33 ± 373N for C7 pedicle screws, and 355 ± 250 N for C2 laminar screws. A student t test indicated no statistical difference in pullout strength between C7 laminar and C7 pedicle screws (P = 0.6). The radiographical anatomy at C7 suggests that intralaminar screws can be placed in the majority of patients. The in vitro biomechanical analysis performed indicates that C7 laminar screws are as strong as C7 pedicle screws and significantly stronger than laminar screws at C2. N/A.