Yan Li

Dr. Yan Li

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2025 in Energies
Verified
Journal Article
Open access
PDF file
YLYan Li
Yan Li
JXJianyuan Xu
Jianyuan Xu
PWPeng Wang
Peng Wang
GLGuanhua Li
Guanhua Li
The development of a single-phase grounding fault arc is influenced by various environmental factors, which can result in the rapid extinction and reignition of the arc. This phenomenon can lead to accidents, such as resonant overvoltage. Current grounding arc models inadequately account for the effects of grounding current, arc length, environmental wind speed, and other variables on the characteristics of the arc. In response to this issue, this article establishes a three-dimensional single-phase grounding arc mathematical model grounded in magnetohydrodynamics. It simulates and analyzes the effects of arc length and environmental wind speed on both arc ignition and extinguishing. Furthermore, an artificial single-phase grounding test platform is constructed within the actual distribution network to validate the accuracy of the simulation model. Research has demonstrated that, under identical operating conditions for both simulation and experimentation, the error range between the simulated arc voltage and the measured data is within 8%. The three-dimensional single-phase grounding arc mathematical model effectively describes the dynamic development process of the grounding arc. At a gap of 12 cm, under windless conditions and with a grounding current of 40.0 A, the temperature of the arc column at the peak of the current reaches 2600 K, while the conductivity decreases to 2.1 × 10−4 S/m, resulting in the inability of the arc to sustain a burning state. At a gap of 2 cm and a wind speed of 7 m/s, the temperature of the arc column at the peak of the current reaches 2900 K, the conductivity drops to 4.3 × 10−3 S/m, leading to the extinction of the arc.

29 May 2025 in IEEE Access
Verified
Journal Article
Open access
YLYan Li
Yan Li
JXJianyuan Xu
Jianyuan Xu
ZGZhenxin Geng
Zhenxin Geng
Aiming at the problem of energy exchange in the arc channel of single-phase arc grounding in distribution networks, this paper establishes a three-dimensional, single-phase arc grounding field-circuit coupled mathematical model based on magnetohydrodynamics. It analyzes the process of arc energy exchange, considers the competitive relationship among the input energy, dissipated energy, and the energy of arc itself under varying wind speeds, and conducts artificial single-phase arc grounding tests in actual distribution networks to validate the accuracy of the arc mathematical model. The research findings indicate that the simulation calculations begin with a voltage phase angle of 0°. At a wind speed of 1 m/s, the energy of arc itself increases in a step-like manner, and the arc burns stably. At wind speeds of 3 m/s and 5 m/s, the energy of arc itself exhibits a phenomenon of repeated fluctuations, rising to a peak before rapidly declining. At this moment, the arc does not extinguish; rather, the extinguishing occurs at the first current zero-crossing point following this peak. Higher wind speeds facilitate the extinguishing of the arc. The first extinguishing times corresponding to wind speed of 3 m/s and 5 m/s are 284 ms and 204 ms, respectively. After the arc extinguishes, a re-ignition phenomenon occurs, with higher wind speeds resulting in a longer interval between extinguishing and re-ignition.