The development of a single-phase grounding fault arc is influenced by various environmental factors, which can result in the rapid extinction and reignition of the arc. This phenomenon can lead to accidents, such as resonant overvoltage. Current grounding arc models inadequately account for the effects of grounding current, arc length, environmental wind speed, and other variables on the characteristics of the arc. In response to this issue, this article establishes a three-dimensional single-phase grounding arc mathematical model grounded in magnetohydrodynamics. It simulates and analyzes the effects of arc length and environmental wind speed on both arc ignition and extinguishing. Furthermore, an artificial single-phase grounding test platform is constructed within the actual distribution network to validate the accuracy of the simulation model. Research has demonstrated that, under identical operating conditions for both simulation and experimentation, the error range between the simulated arc voltage and the measured data is within 8%. The three-dimensional single-phase grounding arc mathematical model effectively describes the dynamic development process of the grounding arc. At a gap of 12 cm, under windless conditions and with a grounding current of 40.0 A, the temperature of the arc column at the peak of the current reaches 2600 K, while the conductivity decreases to 2.1 × 10−4 S/m, resulting in the inability of the arc to sustain a burning state. At a gap of 2 cm and a wind speed of 7 m/s, the temperature of the arc column at the peak of the current reaches 2900 K, the conductivity drops to 4.3 × 10−3 S/m, leading to the extinction of the arc.
In direct-current gas-insulated transmission lines (DC GIL), complex heat transfer processes accelerate surface charge accumulation on insulators, causing local electric field distortion and elevating the risk of surface flashover. This study develops a three-dimensional multi-physics coupled mathematical model for ±200 kV DC GIL basin-type insulators. The bulk and surface conductivity of insulator materials were experimentally measured under varying temperature and electric field conditions, with fitting equations derived to describe their behavior. The model investigates surface charge accumulation and electric field distribution under DC voltage and polarity-reversal conditions, incorporating multi-field coupling effects. Results show that, at a 3150 A current in a horizontally arranged DC GIL, insulator temperatures reach approximately 62.8 °C near the conductor and 32 °C near the enclosure, with the convex surface exhibiting higher temperatures than the concave surface and distinct radial variations. Under DC voltage, surface charge accumulates faster in high-temperature regions, with both charge and electric field distributions stabilizing after approximately 300 h, following significant changes within the first 40 h. Following stabilization, the distribution of surface charge and electric field varies across different radial directions. During polarity reversal, residual surface charges cause electric field distortion, increasing maximum field strength by 13.6% and 47.2% on the convex and concave surfaces, respectively, with greater distortion on the concave surface, as calculated from finite element simulations with a numerical accuracy of ±0.5% based on mesh convergence and solver tolerance. These findings offer valuable insights for enhancing DC GIL insulation performance.
Modular multilevel converter (MMC) tends to cause resonance instability in interconnected systems. Current studies on the stability of MMC mainly focus on high-voltage and large-capacity power systems, while the impedance modeling process of MMC ignores the harmonics of the submodule (SM) capacitor voltages and the influence of voltage feedforward control. The applicability of the MMC impedance model with fewer submodules is doubtful. According to the circuit structure and control mode, the AC-side sequence impedance model of the MMC is established, which takes into account the capacitor voltage balance control of submodules and voltage feedforward control. Based on the RT-Lab control hardware-in-loop (CHIL) test platform, the MMC impedance frequency scanning was carried out to verify the accuracy of the impedance modeling method. The influence of control parameters in different frequency bands on the impedance characteristics of MMC was studied. The AC terminal voltage feedforward causes phase lag in the mid-/high-frequency range and increases the risk of resonance. In the low-frequency range, the dynamics and control of capacitor voltages reduce the impedance magnitude of MMC. Using the resonance phenomenon of an MMC connected to a weak grid as an example, the high-frequency resonance mechanism caused by control parameters is analyzed from the perspective of the negative damping effect. The simulation results show that the detailed wideband impedance model can improve the accuracy of the stability analysis results.
The extensive deployment of Modular Multilevel Converters (MMCs) in AC/DC systems can lead to complex resonance issues. Impedance modeling forms the foundation for analyzing the stability of interconnected system. Existing investigations primarily address resonance concerns on the AC side of MMC. In the process of impedance modeling, the DC system is generally approximated as an ideal voltage source, thereby neglecting its dynamic impact on the impedance characteristic of MMC. Such simplification may result in inaccuracies within stability analysis findings. Based on the multi-harmonic linearization method, this paper introduces an impedance modeling approach that takes into account the characteristics of the DC port. Taking DC voltage control as a case study, the impedance model for the AC side of the MMC is established. The results of programming calculation and simulation measurement of sequence impedance are mutually verified. Finally, the MMC impedance responses determined by different DC port characteristics are analyzed. Significant alterations in MMC impedance characteristics are introduced by DC side resistance and capacitance, which may result in negative damping effects and a decrease in system stability margins. The DC side inductance has a relatively minor impact on MMC impedance responses. The analysis results show that the sequence impedance model of MMC considering DC port characteristics can improve the accuracy of stability analysis results.
Single-phase short-circuit faults are severe asymmetrical fault modes in high renewable energy power systems. They can easily cause large-scale renewable energy to enter the low-voltage ride-through (LVRT) state. When such symmetrical or asymmetrical faults occur in the transmission channels of high-proportion wind power clusters, they may trigger the tripping of thermal power units and a transient voltage drop in most wind turbines in the high-proportion wind power area. This causes an instantaneous active power deficiency and poses a low-frequency oscillation risk. To address the deficiencies of wind turbine units in fault ride-through (FRT) and active frequency regulation capabilities, a power emergency support scheme for wind power clusters based on doubly fed variable-speed pumped storage dynamic excitation is proposed. A dual-channel energy control model for variable-speed pumped storage units is established via AC excitation control. This model provides inertia support and FRT energy simultaneously through AC excitation control of variable-speed pumped storage units. Considering the transient stability of the power network in the wind power cluster transmission system, this scheme prioritizes offering dynamic reactive power to support voltage recovery and suppresses power oscillations caused by power deficiency during LVRT. The electromagnetic torque completed the power regulation within 0.4 s. Finally, the effectiveness of the proposed strategy is verified through modeling and analysis based on the actual power network of a certain region in Northeast China.
Aimed at the large disturbance of a power system caused by frequent new energy clusters going off-grid, we propose a cooperative optimization strategy of variable-speed and constant-speed pumped-storage units to address power oscillation due to significant power shortages following the clusters going off-grid. From a multi-time-scale perspective, we first investigate the fast power support control strategy of variable-speed pumped-storage (VSPS) units during new energy cluster off-grid scenarios. Using a consensus algorithm, the VSPS acts as the primary unit, while the constant-speed unit provides long-term power support. We present a rapid power control method for VSPS to prioritize frequency stability in mainland grids with high new energy penetration. This ensures stable power support for large-scale new energy clusters under large disturbances across multiple time scales. Simulation analysis on a high proportion of new energy power networks with new energy clusters confirms the effectiveness of our proposed method.