As existing distribution networks were designed to deliver unidirectional power to consumers and require minimal control intervention, they result in largely passive infrastructures. The installation of distributed generation (DG) units with significant capacity in these passive networks can cause reverse power flows, which will result in some conflicts with the operation of the existing protection system. In this context, utilities around the world have started establishing requirements to ensure safe and reliable interconnection of generators in low- and medium-voltage networks. The technical grid code requirements and regulations vary considerably from country to country. However, any standard should address the critical need to make the DG marketable by providing uniform criteria and requirements relevant to the performance, operation, and safety. This paper presents a critical review of the requirements adopted by distribution companies in selected countries, such as the U.S., the U.K., Germany, and Australia, to facilitate the connection of DG. The main problems, such as voltage regulation, islanding operation, and dynamic interactions among DG and loads, are discussed to identify a few points where attention is still needed to improve the reliability of distribution systems.
29 April 2014 in IEEE Transactions on Power Delivery
This paper presents a robust nonlinear controller design for a three-phase grid-connected photovoltaic (PV) system to control the current injected into the grid and the dc-link voltage for extracting maximum power from PV units. The controller is designed based on the partial feedback linearization approach, and the robustness of the proposed control scheme is ensured by considering structured uncertainties within the PV system model. An approach for modeling the uncertainties through the satisfaction of matching conditions is provided. The superiority of the proposed robust controller is demonstrated on a test system through simulation results under different system contingencies along with changes in atmospheric conditions. From the simulation results, it is evident that the robust controller provides excellent performance under various operating conditions.
26 September 2013 in IEEE Journal of Photovoltaics
This paper presents a robust stabilization scheme for a three-phase grid-connected photovoltaic system to control the current injected into the grid and dc-link voltage to extract maximum power from photovoltaic (PV) units. The scheme is mainly based on the design of a robust controller using a partial feedback linearizing approach of feedback linearization, where the robustness of the proposed scheme is ensured by considering uncertainties within the PV system model. In this paper, the uncertainties are modeled as structured uncertainties based on the satisfaction of matching conditions. The performance of the proposed stabilization scheme is evaluated on a three-phase grid-connected PV system in terms of delivering maximum power under changes in atmospheric conditions.
This paper presents an economical expediency of grid connected hybrid (PV/Wind turbine) power system for rural area applications in the southern city of Bangladesh, Lobon Chora, Khulna. The analysis is carried out by investigating the potentials of wind and solar energy and collecting data from different sources. Hybrid Optimization Model for Electric Renewable (HOMER) software is used to analyze the available data and economic feasibility of the proposed hybrid power system. In this paper, two types of models named off-grid and on-grid are designed and optimized for comparison purposes. Also, a sensitivity analysis has been performed for each model in order to determine the effect of variations in grid energy cost on its total cost. The simulation results indicate that the proposed grid connected hybrid (PV/Wind turbine) power system is most suitable and cost competitive for the mentioned region.