Anna Davidoviča

Mrs. Anna Davidoviča


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 February 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ADAnna Davidoviča
Anna Davidoviča
GSGuna Semjonova
Guna Semjonova
LKLydia Kamynina
Lydia Kamynina
LLLinda Lancere
Linda Lancere
AJAlise Jonate
Alise Jonate
SDSergejs Davidovics
Sergejs Davidovics
Football players, particularly in youth leagues, face a high risk of lower limb injuries due to improper movement patterns. While programs like FIFA 11+ help reduce injuries, they lack real-time, personalized feedback for biomechanical correction. This concept protocol outlines the development of a DAid® smart socks-based biofeedback system that integrates biomechanical monitoring with mixed reality (MR) feedback to enhance injury prevention. The DAid® smart socks, equipped with pressure sensors and inertial measurement units (IMUs), track plantar pressure distribution and the center of pressure (COP). Real-time feedback is delivered via a Meta Quest 3 MR headset, enabling athletes to adjust movement patterns instantly. This protocol establishes a framework for evaluating the system’s feasibility and effectiveness in optimizing biomechanics and reducing injury risks. By combining wearable technology with MR-based feedback, this study advances injury prevention strategies, with potential applications in rehabilitation and performance training.

10 July 2025 in JMIR Formative Research
Verified
Journal Article
Open access
ADAnna Davidoviča
Anna Davidoviča
SDSergejs Davidovičs
Sergejs Davidovičs
GSGuna Semjonova
Guna Semjonova
AKAlexei Katashev
Alexei Katashev
AOAlexander Oks
Alexander Oks
MZMaksims Zolovs
Maksims Zolovs
Background: Football is the most widely played sport globally but carries a high risk of lower limb injuries, particularly among youth athletes. Real-time biomechanical monitoring can play a critical role in injury prevention. However, traditional lab-based systems are often complex and impractical for field use. Recent advances in wearable technology, such as inertial sensors and smart socks, provide more accessible solutions for movement analysis. The DAid smart sock system is a promising tool, but further evidence is needed to support its use in lower extremity functional assessments. Objective: This correlational study aimed to investigate the correlation between lower limb joint angles, muscle activity, and plantar pressure distribution during the “Single Leg Squat” (SLS) and its variations in youth football players, using wireless wearable sensors in a field-based setting. Methods: In total, 32 youth football players (16 male and 16 female individuals; mean age 14.6, SD 0.5 years) performed SLS movements while wearing the NOTCH inertial motion sensors, DAid smart socks (plantar pressure), and PLUX muscleBAN EMG system. Spearman correlation was used to explore relationships between hip, knee, and ankle joint kinematics; muscle activity (gluteus medius, gluteus maximus [GMx], vastus lateralis, and biceps femoris); and changes in center of pressure (COP) on the plantar surface. Results: A strong positive correlation was found between hip adduction and medial foot pressure (COP1X: ρ=0.785, P<.001). Knee flexion was strongly correlated with gluteus medius (ρ=0.809) and GMx (ρ=0.841) muscle activity. Hip internal rotation also showed moderate to strong correlations with both COP variables (COP1Y: ρ=0.585) and GMx activation (ρ=0.477). Significant gender-specific differences were identified: male individuals showed stronger correlations between joint angles and muscle activation, while female individuals demonstrated a strong correlation between knee flexion and overall plantar pressure (COP2W: ρ=0.818). Several moderate correlations (0.35<ρ<0.47) further confirmed interactions between joint movement, muscle activity, and plantar pressure. Conclusions: The findings support the feasibility and utility of wireless wearable sensors—including inertial measurement units and smart socks—for in-field biomechanical analysis in youth football players. The study confirmed key relationships between joint mechanics and plantar pressure distribution, suggesting their relevance in injury risk screening. The DAid smart sock system, in particular, demonstrated reliable performance for assessing medial-lateral loading patterns associated with hip and knee movement. These insights may help guide neuromuscular training and individualized injury prevention strategies in young athletes.

Verified
Journal Article
Open access
PDF file
GSGuna Semjonova
Guna Semjonova
RVRodrigo Vallejo-Martínez
Rodrigo Vallejo-Martínez
LLLuis Ceballos Laita
Luis Ceballos Laita
SJSandra Jiménez-del-Barrio
Sandra Jiménez-del-Barrio
SDSergejs Davidovics
Sergejs Davidovics
ADAnna Davidoviča
Anna Davidoviča
Objectives: To systematically synthesize existing evidence on functional biomechanical tests of the foot and ankle in physiotherapy and sports, focusing on their outcome measures, compatibility with wearable sensor technologies, and psychometric properties. Methods: We performed a systematic review (PRISMA-guided) of PubMed, Web of Science, PEDro, and SPORTDiscus from inception to December 2025. Eligible studies evaluated functional foot/ankle biomechanics in athletes, healthy adults, or adults with musculoskeletal foot/ankle conditions using wearable sensors (e.g., IMUs, wireless pressure insoles). Two reviewers independently screened, extracted data, and appraised methodological quality using the COSMIN Risk of Bias tool, applying property-specific ratings. Heterogeneity precluded meta-analysis; findings were narratively synthesized and tabulated. Results: Twenty full texts were reviewed; four studies (n = 83 participants) met the inclusion criteria. Wearable devices included foot- or trunk-mounted IMUs and wireless pressure insoles. Reported outcomes spanned temporal gait events and inner-stance phases, vertical ground reaction force (vGRF) and centre-of-pressure trajectories, running step rate/stride length, and jump counts in competition. Validity was most frequently assessed: foot-worn IMUs showed millisecond-level agreement with in-shoe pressure references for stance and inner-stance events; pressure insoles demonstrated acceptable agreement with force plates for vGRF/COP alongside fair-to-excellent test–retest reliability; foot- vs. shank-mounted IMUs provided strong agreement for running step rate and stride length; and competition-based jump detection using IMUs achieved high sensitivity. Across studies, reliability indices were inconsistently reported, measurement error (SEM/MDC) was sparse, and MCID was not reported. The COSMIN appraisal ranged from very good/adequate to inadequate, driven primarily by small sample sizes, non-gold-standard comparators, and incomplete psychometric reporting.

27 December 2025 in Healthcare
Verified
Journal Article
Open access
PDF file
ADAnna Davidoviča
Anna Davidoviča
GSGuna Semjonova
Guna Semjonova
AKAlexei Katashev
Alexei Katashev
AOAlexander Oks
Alexander Oks
DŅDarja Ņesteroviča-Petrikova
Darja Ņesteroviča-Petrikova
STSigne Tomsone
Signe Tomsone
Background/Objectives: Accurate plantar pressure assessment is essential for injury prevention and rehabilitation monitoring in sports. Wearable sensor technologies, such as DAid® Smart Socks, offer portable, real-time biomechanical feedback and enable data collection in field conditions. However, there is limited evidence on their level of agreement with a gold standard in measuring the foot plantar center of pressure (CoP) in football-specific tasks. This study aimed to determine the preliminary validity of DAid® Smart Socks compared with a gold-standard force platform in measuring plantar center of pressure (CoP) during functional football FIFA 11+ Part 2 exercises. Methods: Ten male volunteer youth football players (mean age 12.2 ± 0.42 years; height 158.7 ± 7.72 cm; weight 46.46 ± 8.78 kg; shoe size EU 39.8 ± 2.68) from the Latvian Football Federation Youth League participated. Eight players had right-leg dominance, two had left-leg dominance; three reported past lower-limb injuries. Plantar pressure was measured simultaneously using DAid® Smart Socks and a 1.5 m entry-level force platform with a calibration factor of 3.2. Center of pressure (CoP) data from the force platform were recorded using Footscan software version 9.10.4. Participants performed two selected FIFA 11+ Part 2 exercises—a single-leg squat (unilateral) and a squat with heel raise, performed bilaterally—under standardized conditions. Each exercise was performed twice, with sock removal and reapplication between trials. Agreement between the DAid® Smart Socks and the force platform was examined using waveform synchronization, root mean square error (RMSE), Bland–Altman analysis, and Lin’s Concordance Correlation Coefficient (CCC) to quantify both relative waveform correspondence and absolute CoP measurement accuracy. Results: Across 160 paired recordings, the DAid® Smart Socks showed moderate-to-high correlation with the force platform for relative CoP dynamics, with 79% of waveforms demonstrating CCC ≥ 0.60. Absolute agreement was limited, with only 16% of recordings reaching CCC ≥ 0.90, and RMSE values ranging from 2.1 to 18.9 mm (X) and 4.3–34.2 mm (Y). Conclusions: DAid® Smart Socks showed moderate-to-high correspondence with the force platform in capturing the directional and temporal characteristics of plantar CoP during functional football tasks, with agreement varying across individuals.

20 November 2024 in JMIR Preprints
Verified
Preprint
Open access
ADAnna Davidoviča
Anna Davidoviča
SDSergejs Davidovics
Sergejs Davidovics
GSGuna Semjonova
Guna Semjonova
AKAlexei Katashev
Alexei Katashev
AOAlexander Oks
Alexander Oks
MZMaksims Zolovs
Maksims Zolovs
BACKGROUND Football, the world's most popular sport, carries significant injury risks, especially for youth players. Real-time monitoring of movement patterns is crucial for reducing these risks. Traditional methods often require multiple sensor systems to measure various biomechanical parameters, making the process complex and challenging. The DAid® smart sock system offers a user-friendly alternative, but its effectiveness as a standalone tool for comprehensive lower extremity monitoring requires validation. OBJECTIVE This study aims to investigate the correlations between biomechanical variables of lower extremity movements during the "Single Leg Squat" functional test and its variations in youth league football players, using wireless sensor systems in field tests. METHODS Thirty-two youth league football players (aged 14-15; 16 males, 16 females) participated in the study, performing the "Single Leg Squat" test and its variations using the NOTCH® inertial sensor system, DAid® smart socks, and PLUX Wireless Biosignals (muscleBAN kit). Correlations between lower limb biomechanical variables were analysed using data from these systems. RESULTS The study found a strong positive correlation between hip adduction and changes in the centre of pressure on the medial plantar surface (COP1X: r=0.785, p<.001). Hip internal rotation also showed a significant positive correlation with centre of pressure changes (COPY1: r=0.585, p<.01). CONCLUSIONS Significant correlations exist between the foot centre of pressure, lower limb movement, and muscle activity during the "Single Leg Squat". These findings demonstrate the relevance of the wireless sensor systems used in this study for assessing correlations in lower limb biomechanics in football players, with the DAid® smart sock system serving as one of the tools to facilitate this assessment.