Janice Kiely

Prof. Janice Kiely


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 July 2014 in Biosensors
Verified
Journal Article
Open access
PDF file
JBJacqueline Barnett
Jacqueline Barnett
PWPatrick Wraith
Patrick Wraith
JKJanice Kiely
Janice Kiely
RPRaj Persad
Raj Persad
KHKatrina Hurley
Katrina Hurley
RLRichard Luxton
Richard Luxton
We describe the detection characteristics of a device the Resonant Coil Magnetometer (RCM) to quantify paramagnetic particles (PMPs) in immunochromatographic (lateral flow) assays. Lateral flow assays were developed using PMPs for the measurement of total prostate specific antigen (PSA) in serum samples. A detection limit of 0.8 ng/mL was achieved for total PSA using the RCM and is at clinically significant concentrations. Comparison of data obtained in a pilot study from the analysis of serum samples with commercially available immunoassays shows good agreement. The development of a quantitative magneto-immunoassay in lateral flow format for total PSA suggests the potential of the RCM to operate with many immunoassay formats. The RCM has the potential to be modified to quantify multiple analytes in this format. This research shows promise for the development of an inexpensive device capable of quantifying multiple analytes at the point-of-care using a magneto-immunoassay in lateral flow format.

25 March 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Open access
XYXicai Yue
Xicai Yue
JKJanice Kiely
Janice Kiely
DGDesmond Gibson
Desmond Gibson
EDEmmanuel M. Drakakis
Emmanuel M. Drakakis
Supercapacitors offer an attractive energy storage solution for lifetime “fit and forget” photovoltaic (PV) energy harvesting powered wireless sensor nodes for internet of things (IoT) applications. Whilst their low storage capacity is not an issue for sub-mW PV applications, energy loss in the charge redistribution process is a concern. Currently there is no effective method to estimate the storage of the supercapacitor in IoT applications for optimal performance with sub-mW input. The existing energy-based method requires supercapacitor model parameters to be obtained and the initial charge state to be determined, consequently it is not suitable for practical applications. This paper defines a charge-based method, which can directly evaluate supercapacitor's storage with straightforward calculations. Time constant analysis and experimental tests demonstrate that with the newly proposed method the manufacturer-specified tiny leakage current, although measured long after post-charge (e.g. 72 hours), can be directly used, making the storage estimation for a supercapacitor in IoT applications as simple as that for an ordinary capacitor. In addition, the demonstrated tiny leakage current at the required energy storage for a sub-mW PV powered IoT application enables a supercapacitor alone to be employed as the storage mechanism, thus achieving lifetime battery-replacement-free, self-powered IoT nodes.

19 April 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
AMAuwal Muhammad Musa
Auwal Muhammad Musa
JKJanice Kiely
Janice Kiely
RLRichard Luxton
Richard Luxton
Kevin HoneychurchKevin Honeychurch
Kevin Honeychurch
In this study, a screen-printed electrode (SPE) modified with gold-nanoparticle-decorated reduced graphene oxide–carbon nanotubes (rGO-AuNPs/CNT/SPE) was used for the determination of estradiol (E2). The AuNPs were produced through an eco-friendly method utilising plant extract, eliminating the need for severe chemicals, and remove the requirements of sophisticated fabrication methods and tedious procedures. In addition, rGO-AuNP serves as a dispersant for the CNT to improve the dispersion stability of CNTs. The composite material, rGO-AuNPs/CNT, underwent characterisation through scanning electron microscopy (SEM), ultraviolet–visible absorption spectroscopy (UV–vis), Fourier-transform infrared (FTIR) spectroscopy, and atomic force microscopy (AFM). The electrochemical performance of the modified SPE for estradiol oxidation was characterised using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. The rGO-AuNPs/CNT/SPE exhibited a notable improvement compared to bare/SPE and GO-CNT/SPE, as evidenced by the relative peak currents. Additionally, we employed a baseline correction algorithm to accurately adjust the sensor response while eliminating extraneous background components that are typically present in voltammetric experiments. The optimised estradiol sensor offers linear sensitivity from 0.05–1.00 µM, with a detection limit of 3 nM based on three times the standard deviation (3δ). Notably, this sensing approach yields stable, repeatable, and reproducible outcomes. Assessment of drinking water samples indicated an average recovery rate of 97.5% for samples enriched with E2 at concentrations as low as 0.5 µM%, accompanied by only a modest coefficient of variation (%CV) value of 2.7%.

3 September 2012 in Robotics and Computer-Integrated Manufacturing
Verified
Journal Article
Closed access
CKC. Kohrt
C. Kohrt
RSR. Stamp
R. Stamp
APA.G. Pipe
A.G. Pipe
JKJanice Kiely
Janice Kiely
GSG. Schiedermeier
G. Schiedermeier

6 April 2019 in Materials
Verified
Journal Article
Open access
PDF file
LCLu Cao
Lu Cao
JKJanice Kiely
Janice Kiely
Martina PianoMartina Piano
Martina Piano
RLRichard Luxton
Richard Luxton
In this study, biosensors based on zinc oxide–copper oxide composite nano-surfaces were prepared using a simple and inexpensive distributed colloidal technique. Combinations of mixed dispersions with volume ratios of 1:1, 1:2 and 2:1 ZnO:CuO were compared. The uniform nano-crystalline sensor surfaces on polyethylene terephthalate (PET) were analysed using scanning electron microscopy (SEM), Atomic Force Microscopy (AFM) and Raman Spectroscopy. The ZnO–CuO composite biosensor nano-surfaces showed a significantly increased impedimetric signal compared with pure ZnO nanocrystals, and the maximum output was achieved with a volume ratio of 1:2 ZnO/CuO. The antibody capture of C-reactive protein (CRP) on the nano-surfaces was used to demonstrate the enhanced signal generated with increasing amounts of CuO in the nano-surface.

1 June 2009 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
JEJohn Eveness
John Eveness
JKJanice Kiely
Janice Kiely
PHPeter Hawkins
Peter Hawkins
PWPatrick Wraith
Patrick Wraith
RLRichard Luxton
Richard Luxton