Bahaaeldeen M. Elgarba

Dr. Bahaaeldeen M. Elgarba

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 February 2024 in Journal of Dentistry
Verified
Journal Article
Open access
BEBahaaeldeen M. Elgarba
Bahaaeldeen M. Elgarba
RFRocharles Cavalcante Fontenele
Rocharles Cavalcante Fontenele
MTMihai TARCE
Mihai TARCE
RJReinhilde Jacobs
Reinhilde Jacobs
To conduct a scoping review focusing on artificial intelligence (AI) applications in presurgical dental implant planning. Additionally, to assess the automation degree of clinically available pre-surgical implant planning software. A systematic electronic literature search was performed in five databases (PubMed, Embase, Web of Science, Cochrane Library, and Scopus), along with exploring gray literature web-based resources until November 2023. English-language studies on AI-driven tools for digital implant planning were included based on an independent evaluation by two reviewers. An assessment of automation steps in dental implant planning software available on the market up to November 2023 was also performed. From an initial 1,732 studies, 47 met eligibility criteria. Within this subset, 39 studies focused on AI networks for anatomical landmark-based segmentation, creating virtual patients. Eight studies were dedicated to AI networks for virtual implant placement. Additionally, a total of 12 commonly available implant planning software applications were identified and assessed for their level of automation in pre-surgical digital implant workflows. Notably, only six of these featured at least one fully automated step in the planning software, with none possessing a fully automated implant planning protocol. AI plays a crucial role in achieving accurate, time-efficient, and consistent segmentation of anatomical landmarks, serving the process of virtual patient creation. Additionally, currently available systems for virtual implant placement demonstrate different degrees of automation. It is important to highlight that, as of now, full automation of this process has not been documented nor scientifically validated. Scientific and clinical validation of AI applications for presurgical dental implant planning is currently scarce. The present review allows the clinician to identify AI-based automation in presurgical dental implant planning and assess the potential underlying scientific validation.

29 July 2023 in Journal of Dentistry
Verified
Journal Article
Open access
BEBahaaeldeen M. Elgarba
Bahaaeldeen M. Elgarba
SAStijn Van Aelst
Stijn Van Aelst
ASAbdullah Swaity
Abdullah Swaity
NMNermin Morgan
Nermin Morgan
SSSohaib Shujaat
Sohaib Shujaat
RJReinhilde Jacobs
Reinhilde Jacobs
To train and validate a cloud-based convolutional neural network (CNN) model for automated segmentation (AS) of dental implant and attached prosthetic crown on cone-beam computed tomography (CBCT) images. A total dataset of 280 maxillomandibular jawbone CBCT scans was acquired from patients who underwent implant placement with or without coronal restoration. The dataset was randomly divided into three subsets: training set (n = 225), validation set (n = 25) and testing set (n = 30). A CNN model was developed and trained using expert-based semi-automated segmentation (SS) of the implant and attached prosthetic crown as the ground truth. The performance of AS was assessed by comparing with SS and manually corrected automated segmentation referred to as refined-automated segmentation (R-AS). Evaluation metrics included timing, voxel-wise comparison based on confusion matrix and 3D surface differences. The average time required for AS was 60 times faster (<30 s) than the SS approach. The CNN model was highly effective in segmenting dental implants both with and without coronal restoration, achieving a high dice similarity coefficient score of 0.92±0.02 and 0.91±0.03, respectively. Moreover, the root mean square deviation values were also found to be low (implant only: 0.08±0.09 mm, implant+restoration: 0.11±0.07 mm) when compared with R-AS, implying high AI segmentation accuracy. The proposed cloud-based deep learning tool demonstrated high performance and time-efficient segmentation of implants on CBCT images. AI-based segmentation of implants and prosthetic crowns can minimize the negative impact of artifacts and enhance the generalizability of creating dental virtual models. Furthermore, incorporating the suggested tool into existing CNN models specialized for segmenting anatomical structures can improve pre-surgical planning for implants and post-operative assessment of peri‑implant bone levels.

22 June 2024 in Journal of Dentistry
Verified
Journal Article
Open access
BEBahaaeldeen M. Elgarba
Bahaaeldeen M. Elgarba
RFRocharles Cavalcante Fontenele
Rocharles Cavalcante Fontenele
FMFrancesco Mangano
Francesco Mangano
RJReinhilde Jacobs
Reinhilde Jacobs
To assess quality, clinical acceptance, time-efficiency, and consistency of a novel artificial intelligence (AI)-driven tool for automated presurgical implant planning for single tooth replacement, compared to a human intelligence (HI)-based approach. To validate a novel AI-driven implant placement tool, a dataset of 10 time-matching cone beam computed tomography (CBCT) scans and intra-oral scans (IOS) previously acquired for single mandibular molar/premolar implant placement was included. An AI pre-trained model for implant planning was compared to human expert-based planning, followed by the export, evaluation and comparison of two generic implants-AI-generated and human-generated-for each case. The quality of both approaches was assessed by 12 calibrated dentists through blinded observations using a visual analogue scale (VAS), while clinical acceptance was evaluated through an AI versus HI battle (Turing test). Subsequently, time efficiency and consistency were evaluated and compared between both planning methods. Overall, 360 observations were gathered, with 240 dedicated to VAS, of which 95 % (AI) and 96 % (HI) required no major, clinically relevant corrections. In the AI versus HI Turing test (120 observations), 4 cases had matching judgments for AI and HI, with AI favoured in 3 and HI in 3. Additionally, AI completed planning more than twice as fast as HI, taking only 198 ± 33 s compared to 435 ± 92 s (p < 0.05). Furthermore, AI demonstrated higher consistency with zero-degree median surface deviation (MSD) compared to HI (MSD=0.3 ± 0.17 mm). AI demonstrated expert-quality and clinically acceptable single-implant planning, proving to be more time-efficient and consistent than the HI-based approach. Presurgical implant planning often requires multidisciplinary collaboration between highly experienced specialists, which can be complex, cumbersome and time-consuming. However, AI-driven implant planning has the potential to allow clinically acceptable planning, significantly more time-efficient and consistent than the human expert.

5 August 2024 in Clinical Oral Implants Research
Verified
Journal Article
Open access
BEBahaaeldeen M. Elgarba
Bahaaeldeen M. Elgarba
RFRocharles Cavalcante Fontenele
Rocharles Cavalcante Fontenele
SASaleem Ali
Saleem Ali
ASAbdullah Swaity
Abdullah Swaity
JMJan Meeus
Jan Meeus
RJReinhilde Jacobs
Reinhilde Jacobs
Objectives: The objective of this study is to assess accuracy, time‐efficiency and consistency of a novel artificial intelligence (AI)‐driven automated tool for cone‐beam computed tomography (CBCT) and intraoral scan (IOS) registration compared with manual and semi‐automated approaches.Materials and Methods: A dataset of 31 intraoral scans (IOSs) and CBCT scans was used to validate automated IOS‐CBCT registration (AR) when compared with manual (MR) and semi‐automated registration (SR). CBCT scans were conducted by placing cotton rolls between the cheeks and teeth to facilitate gingival delineation. The time taken to perform multimodal registration was recorded in seconds. A qualitative analysis was carried out to assess the correspondence between hard and soft tissue anatomy on IOS and CBCT. In addition, a quantitative analysis was conducted by measuring median surface deviation (MSD) and root mean square (RMS) differences between registered IOSs.Results: AR was the most time‐efficient, taking 51.4 ± 17.2 s, compared with MR (840 ± 168.9 s) and SR approaches (274.7 ± 100.7 s). Both AR and SR resulted in significantly higher qualitative scores, favoring perfect IOS‐CBCT registration, compared with MR (p = .001). Additionally, AR demonstrated significantly superior quantitative performance compared with SR, as indicated by low MSD (0.04 ± 0.07 mm) and RMS (0.19 ± 0.31 mm). In contrast, MR exhibited a significantly higher discrepancy compared with both AR (MSD = 0.13 ± 0.20 mm; RMS = 0.32 ± 0.14 mm) and SR (MSD = 0.11 ± 0.15 mm; RMS = 0.40 ± 0.30 mm).Conclusions: The novel AI‐driven method provided an accurate, time‐efficient, and consistent multimodal IOS‐CBCT registration, encompassing both soft and hard tissues. This approach stands as a valuable alternative to manual and semi‐automated registration approaches in the presurgical implant planning workflow.

14 March 2025 in Clinical Oral Implants Research
Verified
Journal Article
Open access
BEBahaaeldeen M. Elgarba
Bahaaeldeen M. Elgarba
RFRocharles Cavalcante Fontenele
Rocharles Cavalcante Fontenele
XDXijin Du
Xijin Du
SMSorana MureșAnu
Sorana MureșAnu
MTMihai Tarce
Mihai Tarce
RJReinhilde Jacobs
Reinhilde Jacobs
Objectives: To validate an innovative artificial intelligence (AI)–driven tool for automated virtual implant placement by comparing its accuracy, implant dimension selection, time efficiency, and consistency with a human intelligence (HI)–based approach for single posterior tooth replacement. Materials and Methods: A dataset of 50 time‐matched cone‐beam computed tomography and intraoral scans with a single missing posterior mandibular tooth was selected to validate a pre‐trained AI model for virtual implant placement against a HI‐based approach. A quantitative comparison of implant location and implant dimension selection was conducted between AI and HI, and a qualitative three‐dimensional evaluation was conducted by three implant dentistry specialists using a visual analog scale and a Turing test to assess and distinguish between AI and HI. Additionally, time consumption and consistency were evaluated. Results: Experts found that approximately 89% of AI‐planned and 93% of HI‐planned implants were clinically acceptable, with the planning method unidentifiable in 58% of AI cases. AI selected implant dimensions of 11.7 mm (1.3) in length and 4.0 mm (0.3) in diameter, close to experts' selections of 11.5 mm (1.3) and 4.2 mm (0.4). AI was over twice as fast, reducing planning time to 187 s (34) compared to 406 s (68) for HI ( p < 0.0001), and demonstrated high consistency with a median surface deviation (MSD) of zero, while intra‐ and inter‐operator MSDs were 0.33 mm (0.14) and 0.56 mm (0.34), respectively ( p < 0.0001). Conclusions: Artificial intelligence is reliable for virtual implant placement in missing mandibular (pre)molars, producing clinically acceptable plans comparable to human experts while operating faster and much more consistently than implant clinicians.

9 January 2025 in Journal of Dentistry
Verified
Journal Article
Open access
DRDébora Costa Ruiz
Débora Costa Ruiz
SMSorana Mureșanu
Sorana Mureșanu
XDXijin Du
Xijin Du
BEBahaaeldeen M. Elgarba
Bahaaeldeen M. Elgarba
RFRocharles Cavalcante Fontenele
Rocharles Cavalcante Fontenele
RJReinhilde Jacobs
Reinhilde Jacobs
To conduct a scoping review on the application of artificial intelligence (AI) in clear aligner therapy and to assess the extent of AI integration and automation in orthodontic software currently available to orthodontists. A systematic electronic literature search was performed in the following databases: PubMed, Embase, Web of Science, Cochrane Library, and Scopus. Also, grey literature resources up to March 2024 were reviewed. English-language studies on potential AI applications for clear aligner therapy were included based on an independent evaluation by two reviewers. An assessment of the automation steps in orthodontic software available on the market up to March 2024 was also conducted. Out of 708 studies, 41 were included. Sixteen articles focused on tooth segmentation, four on registration of digital models, 13 on digital setup, and eight on remote monitoring. Moreover, 13 aligner software programs were identified and assessed for their level of automation. Only one software demonstrated complete automation of the steps involved in the orthodontic digital workflow. None of the 13 identified aligner software programs were evaluated in the 41 included studies. However, AI-based tooth segmentation achieved 98 % accuracy, while AI effectively merged CBCT and IOS data, supported digital measurements, predicted treatment outcomes, and showed potential for remote monitoring. AI applications in clear aligner therapy are on the rise. This scoping review enables orthodontists to identify AI-based solutions in orthodontic planning and understand its implications, which can potentially enhance treatment efficiency, accuracy, and predictability.