Abdullah Swaity

Abdullah Swaity

Auto-generated profile, based on publicly available information

Abdullah Swaity

OMFS‐IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven & Department of Oral and Maxillofacial Surgery University Hospitals Leuven Leuven Belgium

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 August 2024 in Clinical Oral Implants Research
Verified
Journal Article
Open access
BEBahaaeldeen M. Elgarba
Bahaaeldeen M. Elgarba
RFRocharles Cavalcante Fontenele
Rocharles Cavalcante Fontenele
SASaleem Ali
Saleem Ali
ASAbdullah Swaity
Abdullah Swaity
JMJan Meeus
Jan Meeus
RJReinhilde Jacobs
Reinhilde Jacobs
Objectives: The objective of this study is to assess accuracy, time‐efficiency and consistency of a novel artificial intelligence (AI)‐driven automated tool for cone‐beam computed tomography (CBCT) and intraoral scan (IOS) registration compared with manual and semi‐automated approaches.Materials and Methods: A dataset of 31 intraoral scans (IOSs) and CBCT scans was used to validate automated IOS‐CBCT registration (AR) when compared with manual (MR) and semi‐automated registration (SR). CBCT scans were conducted by placing cotton rolls between the cheeks and teeth to facilitate gingival delineation. The time taken to perform multimodal registration was recorded in seconds. A qualitative analysis was carried out to assess the correspondence between hard and soft tissue anatomy on IOS and CBCT. In addition, a quantitative analysis was conducted by measuring median surface deviation (MSD) and root mean square (RMS) differences between registered IOSs.Results: AR was the most time‐efficient, taking 51.4 ± 17.2 s, compared with MR (840 ± 168.9 s) and SR approaches (274.7 ± 100.7 s). Both AR and SR resulted in significantly higher qualitative scores, favoring perfect IOS‐CBCT registration, compared with MR (p = .001). Additionally, AR demonstrated significantly superior quantitative performance compared with SR, as indicated by low MSD (0.04 ± 0.07 mm) and RMS (0.19 ± 0.31 mm). In contrast, MR exhibited a significantly higher discrepancy compared with both AR (MSD = 0.13 ± 0.20 mm; RMS = 0.32 ± 0.14 mm) and SR (MSD = 0.11 ± 0.15 mm; RMS = 0.40 ± 0.30 mm).Conclusions: The novel AI‐driven method provided an accurate, time‐efficient, and consistent multimodal IOS‐CBCT registration, encompassing both soft and hard tissues. This approach stands as a valuable alternative to manual and semi‐automated registration approaches in the presurgical implant planning workflow.

20 May 2024 in International Journal of Paediatric Dentistry
Verified
Journal Article
Open access
SESara Elsonbaty
Sara Elsonbaty
BEBahaaeldeen M. Elgarba
Bahaaeldeen M. Elgarba
RFRocharles Cavalcante Fontenele
Rocharles Cavalcante Fontenele
ASAbdullah Swaity
Abdullah Swaity
RJReinhilde Jacobs
Reinhilde Jacobs
Background: Primary teeth segmentation on cone beam computed tomography (CBCT) scans is essential for paediatric treatment planning. Conventional methods, however, are time‐consuming and necessitate advanced expertise.Aim: The aim of this study was to validate an artificial intelligence (AI) cloud‐based platform for automated segmentation (AS) of primary teeth on CBCT. Its accuracy, time efficiency, and consistency were compared with manual segmentation (MS).Design: A dataset comprising 402 primary teeth (37 CBCT scans) was retrospectively retrieved from two CBCT devices. Primary teeth were manually segmented using a cloud‐based platform representing the ground truth, whereas AS was performed on the same platform. To assess the AI tool's performance, voxel‐ and surface‐based metrics were employed to compare MS and AS methods. Additionally, segmentation time was recorded for each method, and intra‐class correlation coefficient (ICC) assessed consistency between them.Results: AS revealed high performance in segmenting primary teeth with high accuracy (98 ± 1%) and dice similarity coefficient (DSC; 95 ± 2%). Moreover, it was 35 times faster than the manual approach with an average time of 24 s. Both MS and AS demonstrated excellent consistency (ICC = 0.99 and 1, respectively).Conclusion: The platform demonstrated expert‐level accuracy, and time‐efficient and consistent segmentation of primary teeth on CBCT scans, serving treatment planning in children.