In recent years, DC fault arc detection has been an electrical engineering research hotspot. At present, most proposed detection methods do not analyze the effects of fault arc electrical characteristics on both line current and supply voltage. Therefore, this study extensively analyzes variations of the line current and supply voltage because of DC arc faults based on the volt-ampere characteristics of DC arc faults. Then, a DC series arc fault detection method is proposed that comprehensively uses information on line current and supply voltage. An experimental platform for DC fault arc generation and detection was established using a DC-DC converter and a photovoltaic power supply as DC power supplies, and the proposed method was confirmed by experiments using this platform. Experimental results demonstrate that the proposed method can effectively distinguish arc faults and has the characteristics of clear physical meaning while maintaining a low amount of calculation.
The influence of a series arc on line current is different with different loads, which makes it difficult to accurately extract arc fault characteristics suitable for all loads according to line current signal. To improve the accuracy of arc fault detection, a series arc fault detection method based on category recognition and an artificial neural network is proposed on the basis of analyzing the current characteristics of arc faults under different loads. According to the waveform of current and voltage, the load is divided into three types: Resistive category (Re), resistive-inductive category (RI), and rectifying circuit with a capacitive filter category (RCCF). Based on the wavelet transform, the characteristics of line current in the time domain and frequency domain when the series arc occurs under different types of loads are analyzed, and then the time and frequency indicators are taken as the inputs of the artificial neural network to establish three-layer neural networks corresponding to three types of loads to realize the detection of the series arc fault of lines under different categories of loads. To avoid the neural network falling into a local optimum, the initial weight and threshold of the neural network are optimized by a genetic algorithm, which further improves the accuracy of the neural network in arc identification. The experimental results show that the proposed arc detection method has the advantages of high recognition rate and a simple neural network model.
Owing to the shortcomings of existing series arc fault detection methods, based on a summary of arc volt–ampere characteristics, the change rule of the line current and the relationship between the voltage and current are deeply analyzed and theoretically explained under different loads when series arc faults occur. A series arc fault detection method is proposed, and the software flowchart and principles of the applied hardware implementation are given. Finally, a prototype of an arc fault detection device (AFDD) with a rated voltage of 220 V and a rated current of 40 A is developed. The prototype was tested according to experimental methods provided by the Chinese national standard, GB/T 31143-2014. The experimental results show that the proposed detection method is simple and practical, and can be implemented using a low-cost microprocessor. The proposed method will provide good theoretical guidance in promoting the research and development of an AFDD.
This paper presents a modified power supply system based on the current alternating current (AC)-fed railways with neutral zones that can further improve the eco-friendliness and smart level of railways. The modified system complements the existing infrastructure with additional energy-storage-based smart electrical infrastructure. This infrastructure comprises power electronic devices with energy storage system connected in parallel to both sides of each neutral zone in the traction substations, power electronic devices connected in parallel to both sides of each neutral zone in section posts, and an energy management system. The description and functions of such a modified system are outlined in this paper. The system allows for the centralized- and distributed-control of different functions via an energy management system. In addition, a control algorithm is proposed, based on the modified system for regenerative braking energy utilization. This would ensure that all the regenerative braking energy in the whole railway electrical system is used more efficiently. Finally, a modified power supply system with eight power supply sections is considered to be a case study; furthermore, the advantages of the proposed system and the effectiveness of the proposed control algorithm are verified.
AC heavy-haul trains produce a huge amount of regenerative braking energy when they run on long downhill sections. If this energy can be used by uphill trains in the same power supply section, a reduction in coal transportation cost and an improvement in power quality would result. To accurately predict the energy consumption and regenerative braking energy of heavy-haul trains on large long slopes, a single-particle model of train dynamics was used. According to the theory of railway longitudinal section simplification, the energy consumption and the regenerative braking energy model of a single train based on the train attributes, line conditions, and running speed was established. The model was applied and verified on the Shenshuo Railway. The results indicate that the percentage error of the proposed model is generally less than 10%. The model is a convenient and simple research alternative, with strong engineering feasibility. Based on this foundation, a model of train energy consumption was established under different interval lengths by considering the situation of regenerative braking energy in the multi-train operation mode. The model provides a theoretical foundation for future train diagram layout work with the goal of reducing the total train energy consumption.
19 June 2023 in IEEE Transactions on Industrial Electronics
Common-mode voltage (CMV) can greatly reduce the reliability and performance of back-to-back two-level converter-fed motor drive systems. To address this issue, a novel CMV elimination scheme based on reference voltage decomposition is proposed in this article. First, the reference voltage of each phase is decomposed into two virtual reference voltages, resulting in six virtual reference voltages that are inter-related for back-to-back two-level converters. Then, by comparing each virtual reference voltage with a triangle carrier based on the two-level pulsewidth modulation (PWM), the final PWM voltage of each phase can be obtained from the differences between the corresponding two virtual PWM outputs. With the proposed method, both the amplitude and RMS value of CMV can be eliminated theoretically with satisfactory output waveform qualities. Simulations and experimental results are presented to verify the proposed method.