Mingzhe Wu

Mingzhe Wu

Auto-generated profile, based on publicly available information

Mingzhe Wu

School of Mechanical and Electrical Engineering, China University of Mining and Technology, Beijing, China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 July 2022 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
LZLu Zhang
Lu Zhang
CWChen Wang
Chen Wang
JLJun LIANG
Jun LIANG
MWMingzhe Wu
Mingzhe Wu
BZBo Zhang
Bo Zhang
WTWei Tang
Wei Tang
In recent years, the frequent occurrence of extreme natural disasters has caused huge economic losses, which makes it extremely important to improve the resilience of distribution networks. With the increasing penetration of DC sources and loads, the urban distribution network is transitioning from AC to hybrid AC/DC configuration that can operate in a ring structure. The features of flexible interconnections and low network losses of DC lines can break the bottleneck of traditional restoration methods for AC distribution networks under extreme disasters, thereby further enhancing the resilience of distribution networks. Based on the interconnection feature of DC lines, this paper proposes a topology search strategy with DC lines as the core to realize the joint recovery of multiple power sources and multiple critical loads. With the obtained interconnection topology after topology search, a fault restoration model for maximizing the resilience index is established. To ensure the generality of the proposed model and explore the advantages of flexible DC power control, this paper transforms the objective function from the complex model into a mixed integer second-order cone programming (MISOCP) that can be solved directly. The optimal restoration strategy for resilience enhancement of AC/DC hybrid distribution networks can be obtained by solving the proposed MISOCP model. The numerical results in case study validate the effectiveness and superiority of the proposed method.

29 July 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
MWMingzhe Wu
Mingzhe Wu
YLYunwei Li
Yunwei Li
Georgios KonstantinouGeorgios Konstantinou
Georgios Konstantinou
In recent decades, applications of selective harmonic elimination pulsewidth modulation (SHE-PWM) have been extended from two-level to multilevel converters (MLCs). For most MLC topologies, one of the main challenges of using SHE-PWM lies on capacitor voltage balancing, especially with very low switching frequency in high-power applications. Due to the broad variety of MLCs, it is of great difficulty to develop a generalized capacitor voltage balancing method under SHE-PWM that is suitable for all topologies. In order to further facilitate the industrial applications of SHE-PWM on MLCs, this article provides a comprehensive review of the state-of-the-art capacitor voltage balancing strategies for MLCs under SHE-PWM. The voltage balancing methods in this article include self-balancing control, charge amount regulation, zero-sequence harmonic adjustment, redundant switching angle sets adjustment, angle modification, selective harmonic elimination model predictive control, space voltage vectors adjustment, and redundant states adjustment. Detailed comparisons of the eight voltage balancing strategies under SHE-PWM are presented to facilitate the selections of the most suitable method for specific applications. Moreover, discussions on open questions and future trends of this topic are also presented, to motivate future research and explore new alternatives.

3 March 2021 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
MWMingzhe Wu
Mingzhe Wu
CXCheng Xue
Cheng Xue
YLYunwei Li
Yunwei Li
KYKehu Yang
Kehu Yang
In this article, a generalized selective harmonic elimination pulsewidth modulation (SHE-PWM) formulation with common-mode voltage (CMV) reduction ability for multilevel converters (MLCs) is presented. The CMV is suppressed by regulating the low-order dominant zero-sequence harmonics (ZSHs) of the three-phase SHE-PWM waveforms. Two formulations are included in the proposed model to achieve the full range operation objective, i.e., with zero low-order ZSHs in low and medium modulation index (m a ) range and with an optimal third-harmonic injection in high m a range. With the proposed formulation, the amplitude of CMV can be effectively reduced for all types of MLCs over the whole m a range. Besides, two kinds of solving algorithms, i.e., off-line and real-time based, are introduced to provide efficient solution tools targeted at the proposed model. In this article, a case study with three-level neutral-point clamped inverters is discussed in detail to better illustrate the proposed formulation and the coupling effects between the CMV reduction and capacitor voltage balancing objectives of MLCs. Simulation and experimental results based on multiple MLC topologies are carried out to validate the effectiveness of this generalized SHE-PWM formulation with reduced CMV values.

17 June 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
MWMingzhe Wu
Mingzhe Wu
HTHao Tian
Hao Tian
YLYunwei Li
Yunwei Li
Georgios KonstantinouGeorgios Konstantinou
Georgios Konstantinou
KYKehu Yang
Kehu Yang
A composite selective harmonic elimination pulsewidth modulation (SHE-PWM) and model predictive control (MPC) for seven-level hybrid-clamped (7L-HC) inverters is presented in this paper. By introducing the unified SHE formulation, all seven-level switching patterns and corresponding switching angles can be obtained simultaneously. Therefore, the optimal switching pattern with the designed optimization goal of each modulation index can be evaluated and the best expected output performance is achieved. For the voltage balancing issue of 7L-HC, MPC is adopted to control the three-phase flying capacitors and three dc-link capacitors. After receiving the output voltage level signal from the SHE-PWM modulator, the optimal switching state of the received output voltage level that minimizes the cost function is selected by the MPC module, where the cost function is designed to simultaneously balance the capacitor voltages and reduce the switching frequency. Dynamic weighting factors with variable band limits are also proposed to further improve the overall system performance. The potential industrial application of high-power motor drive is used in designing the key parameters for both SHE and MPC parts. Simulation and experiments confirmed the validity of this composite SHE-MPC strategy in reducing the switching frequency and improving the harmonic performance while keeping the capacitor voltages well-balanced.

1 November 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
MWMingzhe Wu
Mingzhe Wu
KWKui Wang
Kui Wang
KYKehu Yang
Kehu Yang
Georgios KonstantinouGeorgios Konstantinou
Georgios Konstantinou
YLYunwei Li
Yunwei Li
YLYongdong Li
Yongdong Li

21 February 2024 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
LZLu Zhang
Lu Zhang
CLChenyu Li
Chenyu Li
MWMingzhe Wu
Mingzhe Wu
YLYunwei Li
Yunwei Li
YCYongxiang Cai
Yongxiang Cai
WTWei Tang
Wei Tang
Ice storms can cause serious damage to power distribution systems, thus the development of effective anti-icing and de-icing strategies is of great significance. In this article, an optimal anti-icing and de-icing coordinated operation scheme is proposed to enhance the resilience of distribution systems against ice storms, which is based on the ice-melting capacity of distribution lines. Firstly, a comprehensive risk analysis for anti-icing and de-icing in ice storms is provided. Then, a novel critical condition for anti-icing initiation is proposed based on the weather forecast deviation and potential load loss in distribution systems. On this basis, the coordinated optimization model for anti-icing and de-icing in distribution networks with intelligent soft open point and energy storage systems is established, aims at minimizing the overall load loss. Considering the double risk of overloading anti-icing and de-icing methods, the power flow limit violation function is used in the optimization model to reasonably allocate the proportion of various risks. Finally, the proposed method is verified in the IEEE 33-node distribution network.