Yuliang Zhu

Dr. Yuliang Zhu

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2025 in Sensors
Verified
Journal Article
Open access
PDF file
WXWenchao Xue
Wenchao Xue
XWXiaobo Wang
Xiaobo Wang
YZYuliang Zhu
Yuliang Zhu
CLChengt Luo
Chengt Luo
For those piezoelectric materials that operate under high-power conditions, the piezoelectric and dielectric properties obtained under small signal conditions cannot be directly applied to high-power transducers. There are three mainstream high-power characterization methods: the constant voltage method, the constant current method, and the transient method. In this study, we developed and verified a combined impedance method that integrated the advantages of the constant voltage and current methods, along with an improved transient method, for high-power testing of PZT-5H piezoelectric ceramics. The results from both methods indicated that with increasing power, the electromechanical coupling coefficient k31 , the piezoelectric constant d31, and the elastic compliance s11E of the PZT-5H showed increasing trends, while the mechanical quality factor Qm first decayed rapidly and then stabilized at a fixed level. Additionally, under the combined impedance method, the temperature of the vibrators rose significantly due to self-heating, whereas the transient method generated almost no heat, and the vibrators remained at room temperature. By comparing the results from the two methods, we decoupled the effects of temperature and power on the high-power piezoelectric performance. The results showed that the self-heating temperature amplified the effects of power on k31, d31, and s11E, while its influence on Qm remained negligible.

25 December 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
XWXiaobo Wang
Xiaobo Wang
RZRongbo Zhang
Rongbo Zhang
YZYuliang Zhu
Yuliang Zhu
BLBofeng Luo
Bofeng Luo
CLChengt Luo
Chengt Luo
THTao Han
Tao Han
The electric field intensity is a critical parameter in electrical power systems, providing significant insights into the system’s condition. Electric field sensors (E-sensors) are essential for monitoring variations in electric field strength. The current challenge facing E-sensors is to achieve the detection of DC electric fields while ensuring a wide dynamic range of field strengths. This paper proposes a novel E-sensor that combines piezoelectric and piezoresistive (PE-PR) elements in its sensitive structure. This paper proposes a novel E-sensor that combines piezoelectric and piezoresistive (PE-PR) elements in its sensitive structure. Shielding plates are positioned on both the upper and lower sides of the PE-PR sensitive element. The conductive states of the two shield plates are controlled through a switching circuit, enabling the modulation and testing of DC electric fields. This design overcomes the incompatibility between DC electric field testing and a wide dynamic range of electric field strengths in E-sensors. This passive sensor can perform electric field measurements within a DC-1.5 kHz bandwidth from 0 to 150 kV/m, with linearity of less than 0.92 %, a field resolution up to 50 V/m, sensitivity reaching 1.06 mV/kV/m (@ 1500 Hz), 128 mV/kV/m (@ DC), and hysteresis error less than 2%. The specifications can be customized according to requirements. Compared to existing research, this electric field sensor meets basic measurement requirements and offers the advantages of a simplified fabrication process and smaller dimensions. The relatively small sensor allows for integration into most power electrical equipment.

24 January 2025 in Actuators
Verified
Journal Article
Open access
PDF file
YZYuliang Zhu
Yuliang Zhu
XWXiaobo Wang
Xiaobo Wang
WXWenchao Xue
Wenchao Xue
XWXinran Wen
Xinran Wen
CLChengt Luo
Chengt Luo
Pb(Mg1/3Nb2/3)O3-PbTiO3 single crystals (PMN-PT SCs) are widely utilized in high-performance piezoelectric devices due to their exceptional piezoelectric properties. Among the various post-processing techniques for domain engineering in PMN-PT SCs, alternating current polarization (ACP) has become a widely adopted method for enhancing piezoelectric performance. This study proposes a new ultrahigh-temperature field-cooling polarization (UFCP) technique, combining direct current polarization (DCP) and ACP with field cooling above the Curie temperature. Dielectric spectra indicate that the UFCP method promotes electric field-induced phase transitions above the Curie point, forming a stable multiphase configuration. The transverse piezoelectric coefficient d31 of UFCP SCs is 1126 pC/N, and the electromechanical coupling factor k31 is 0.559. Compared with traditional DCP, UFCP increases d31 by 68.6%, the mechanical quality factor Qm by 16.7%, and the piezoelectric figure of merit (FOM) by 98.3%. Furthermore, under high-power excitation with a root-mean-square voltage of 15 V, UFCP achieves a 343% increase in power and a 130.5% improvement in the FOM compared with DCP, demonstrating its potential for enhancing high-power performance in practical applications.

12 November 2025 in Sensors
Verified
Journal Article
Open access
PDF file
JDJunwen Deng
Junwen Deng
XCXingyu Chen
Xingyu Chen
YZYuliang Zhu
Yuliang Zhu
XWXiaobo Wang
Xiaobo Wang
THTao Han
Tao Han
CLChengt Luo
Chengt Luo
Gas pipelines are a critical means of transportation in industrial production. To detect gas pipeline leaks, ultrasonic transducers with specific center frequencies and high sensitivity are required. This paper proposes a novel air-coupled ultrasonic transducer design based on a horn-type matching layer and a bending-mode type of piezoelectric material, specifically tailored for gas leak detection scenarios. The transducer design is optimized by the finite element method, focusing on the basic components of the piezoelectric bimorph, the horn and the supporting tube. First, the influence of various dimensional parameters of the piezoelectric bimorph on the bending vibration mode was analyzed. Then, the effects of the other two components, the horn and the supporting tube, on the piezoelectric bimorph vibration mode were investigated. A parametric scan on the dimensions of these components was conducted to optimize the transducer’s output. Finally, ultrasonic transducers using PMN-PT and PZT were fabricated and tested. The results show that the sensitivity of those transducers surpasses that of similar commercial transducers, especially the PMN-PT one with a center frequency of 40 kHz and a peak receiving sensitivity of −51.1 dB. This transducer, benefiting from the high-performance piezoelectric material and the bending vibration mode, proves to be a promising candidate for high-precision leak detection in gas pipelines.

21 January 2026 in Journal of the American Ceramic Society
Verified
Journal Article
Closed access
YZYuliang Zhu
Yuliang Zhu
XWXiaobo Wang
Xiaobo Wang
JDJunwen Deng
Junwen Deng
XCXingyu Chen
Xingyu Chen
LHLinzi Huang
Linzi Huang
THTao Han
Tao Han