Rajveer Sagoo

Mr. Rajveer Sagoo

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
BLBong Lee
Bong Lee
AJAgnieszka Malgorzata Jablonska
Agnieszka Malgorzata Jablonska
DPDanh Pham
Danh Pham
RSRajveer Sagoo
Rajveer Sagoo
ZPZygmunt (Karol) Gryczynski, PhD
Zygmunt (Karol) Gryczynski, PhD
IGIgnacy Gryczynski
Ignacy Gryczynski
We report a comprehensive investigation of the photophysical properties of Hoechst 33258 (HOE) embedded in polyvinyl alcohol (PVA) films. HOE displays a bright, highly polarized, blue fluorescence emission centered at 430 nm, indicating effective immobilization within the polymer matrix of PVA. Its fluorescence quantum yield is notably high (~0.74), as determined relative to a quinine sulfate standard. In addition, we observed that HOE-doped PVA films exhibit room temperature phosphorescence (RTP) that remains visible for several seconds after UV excitation ceases. The slightly negative phosphorescence anisotropy implies that the triplet–singlet radiative transition is orthogonal to the singlet–singlet transition governing fluorescence. Notably, we observed that direct triplet-state excitation at longer wavelengths (beyond the primary absorption band) produces highly polarized RTP. We believe this possibility of direct triplet-state excitation opens new avenues for studying RTP in polymer-immobilized molecules.

4 June 2025 in Photochem
Verified
Journal Article
Open access
PDF file
BLBong Lee
Bong Lee
AJAgnieszka Malgorzata Jablonska
Agnieszka Malgorzata Jablonska
RSRajveer Sagoo
Rajveer Sagoo
DPDanh Pham
Danh Pham
TPTrang Thien Pham
Trang Thien Pham
IGIgnacy Gryczynski
Ignacy Gryczynski
N-phenyl-1H-Indole-5-carboxamide (Ind-CA) exhibits previously unknown room-temperature phosphorescence (RTP) when immobilized in poly (vinyl alcohol) film (PVA film). High-fluorescence anisotropy of Ind-CA in PVA suggests that the fluorophores are strongly immobilized in a polymer matrix, while a relatively low (ca. 0.1) quantum yield indicates a strong non-radiative singlet excited state deactivation. With an increased triplet-state population, Ind-CA can be used for various phosphorescence studies. The room-temperature phosphorescence (RTP) capability of Ind-CA indicates that there is an intricate balance between RTP and the structure of the indole-containing luminophore, as an isomeric N-1H-indole-5-ylbenzamide (Ind-BA) does not show any appreciable levels of RTP. Moreover, the phosphorescence lifetime of Ind-CA is about two orders of magnitude longer than many other 5-substituted indoles. These results further highlight the prospects for the potential rational designs of small molecules with desired triplet-state configuration and RTP characteristics.

1 October 2024 in Heart Rhythm O2
Verified
Journal Article
Open access
RSRajveer Sagoo
Rajveer Sagoo
NSNavraj S. Sagoo
Navraj S. Sagoo
AHAli S. Haider
Ali S. Haider
MSMohanakrishnan Sathyamoorthy
Mohanakrishnan Sathyamoorthy
BACKGROUND The adoption of leadless pacemakers (LPMs) is increasing, yet the impact of body mass index (BMI) on procedural outcomes remains underexplored. OBJECTIVE The purpose of this study was to explore the impact of BMI on in-hospital outcomes for patients receiving LPM implantation. METHODS Data from the National Inpatient Sample from 2018- 2021 were analyzed for patients older than 18 years who underwent LPM implantation, with specific inclusion and exclusion criteria applied. Patients were identified using International Classification of Diseases 10th Revision codes and categorized into BMI groups: underweight, normal, overweight, obese, and morbidly obese. The primary outcome assessed was in-hospital mortality. Secondary outcomes included blood transfusion, pericardial complications, infection/inflammation, removal/revision, and other complications. RESULTS The study included 3832 patients who underwent LPM implantation between 2018 and 2021, weighted to represent 19,610 patients, with 3540 having an appropriate BMI designation. Mortality was lower in the obese group (2.3%) compared to the non-obese group (2.7%) (adjusted odds ratio [aOR] 0.462, 95% confidence interval [CI] 0.259-0.623, P = . 009). Compared to the normal weight group, those categorized as overweight, obese, and morbidly obese demonstrated a lower risk of in-hospital mortality (aOR 0.432, 95% CI 0.299-0.734, P = . 009; aOR 0.465, 95% CI 0.238-0.721, P <. 001; aOR 0.299, 95% CI 0.153-0.586, P <. 001, respectively). CONCLUSION These findings support the existence of the obesity paradox in patients with LPM implantation, where higher BMI categories are associated with improved mortality outcomes, meeting our prespecified primary endpoint. Further studies are needed to clarify the mechanisms behind these observations.

18 May 2026 in Luminescence
Verified
Journal Article
Open access
BWBeata Wielgus-Kutrowska
Beata Wielgus-Kutrowska
JWJacek Wierzchowski
Jacek Wierzchowski
ASAlicja Stachelska-Wierzchowska
Alicja Stachelska-Wierzchowska
JKJoanna Krasowska
Joanna Krasowska
BLBong Lee
Bong Lee
IGIgnacy Gryczynski
Ignacy Gryczynski
The luminescence properties of N 2 ,3‐etheno‐2‐aminopurine (N 2 ,3‐ε2APu) have been studied using steady‐state and time‐resolved spectroscopy. N 2 ,3‐ε2APu was embedded in poly(vinyl alcohol) (PVA) polymer, which is known for effective immobilization of dissolved fluorophore molecules. Upon UV excitation, N 2 ,3‐ε2APu shows a bright dark‐blue fluorescence with high fluorescence anisotropy, indicating efficient immobilization. Time‐resolved fluorescence measurements show a somewhat heterogeneous lifetime, requiring a lifetime distribution model to fit the data. The fit reveals a central lifetime of about 5 ns and a half‐width of the Lorentzian distribution of about 2 ns. We attribute this lifetime spread to the varying surroundings of fluorophore molecules in the polymer matrix. The N 2 ,3‐ε2APu‐doped PVA films exhibit strong room‐temperature phosphorescence (RTP) centered at 500 nm, with a lifetime of approximately 0.15 s. The excitation at 330 nm results in negative phosphorescence anisotropy. Interestingly, N 2 ,3‐ε2APu–doped PVA films can be directly excited to a triplet state at longer wavelengths (above 400 nm). This excitation results in a high positive phosphorescence anisotropy, reaching a value of 0.3 at about 450 nm. The ability to excite a molecule at longer wavelengths may find applications in the biomedical sciences, particularly in the study of photo‐chemically labile proteins and their complexes with emitting ligands.

7 October 2024
Verified
Preprint
Open access
RSRajveer Sagoo
Rajveer Sagoo
NSNavraj S. Sagoo
Navraj S. Sagoo
DPDanh Pham
Danh Pham
ASAniruth Srinivasaraghavan
Aniruth Srinivasaraghavan
KNKatherine Nguyen
Katherine Nguyen
AHAli S. Haider
Ali S. Haider

14 January 2026 in Optics
Verified
Journal Article
Open access
PDF file
AJAgnieszka Malgorzata Jablonska
Agnieszka Malgorzata Jablonska
BLBong Lee
Bong Lee
RPR. Max Petty
R. Max Petty
DPDanh Pham
Danh Pham
RSRajveer Sagoo
Rajveer Sagoo
IGIgnacy Gryczynski
Ignacy Gryczynski
We report the first observation of room-temperature phosphorescence (RTP) of quinine sulfate (QS) in poly (vinyl alcohol) (PVA) films. Steady-state and time-gated measurements were performed to characterize the phosphorescence spectra, anisotropies, and lifetimes to estimate the phosphorescence properties. The RTP response of organic emitters in polymer matrices is particularly sensitive to ambient humidity and oxygen levels. Hence, to assess the environmental stability of the system, QS-doped PVA films were cast from a single batch and divided into paired specimens, one of which was encapsulated with a pressure-sensitive laminate, while the other one was left non-laminated. Over 14 days under ambient laboratory conditions, the absorbance and fluorescence of both films remained unchanged, whereas the exhibited phosphorescence diverged significantly. The unlaminated film exhibited a progressive loss of afterglow intensity, a noticeable red shift in the phosphorescence spectrum, and a pronounced shortening of the phosphorescence lifetime, while the laminated film retained its initial RTP intensity, spectral profile, and lifetime throughout the entire experiment.