Jiann-Shing Shieh

Prof. Jiann-Shing Shieh

Department of Mechanical Engineering, Graduate School of Biotechnology and Bioengineering, Graduate Program in Biomedical Informatics, Yuan Ze University, Taoyuan, Chung-Li 32003, Taiwan

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Jerry ChenJerry Chen
Jerry Chen
Maysam AbbodMaysam Abbod
Maysam Abbod
Jiann-Shing ShiehJiann-Shing Shieh
Jiann-Shing Shieh
Pain is a subjective feeling; it is a sensation that every human being must have experienced all their life. Yet, its mechanism and the way to immune to it is still a question to be answered. This review presents the mechanism and correlation of pain and stress, their assessment and detection approach with medical devices and wearable sensors. Various physiological signals (i.e., heart activity, brain activity, muscle activity, electrodermal activity, respiratory, blood volume pulse, skin temperature) and behavioral signals are organized for wearables sensors detection. By reviewing the wearable sensors used in the healthcare domain, we hope to find a way for wearable healthcare-monitoring system to be applied on pain and stress detection. Since pain leads to multiple consequences or symptoms such as muscle tension and depression that are stress related, there is a chance to find a new approach for chronic pain detection using daily life sensors or devices. Then by integrating modern computing techniques, there is a chance to handle pain and stress management issue.

22 September 2020 in Electronics
Verified
Journal Article
Open access
PDF file
VAVenkat Anil Adibhatla
Venkat Anil Adibhatla
HCHuan-Chuang Chih
Huan-Chuang Chih
CHChi-Chang Hsu
Chi-Chang Hsu
JCJoseph Cheng
Joseph Cheng
Maysam AbbodMaysam Abbod
Maysam Abbod
Jiann-Shing ShiehJiann-Shing Shieh
Jiann-Shing Shieh
In this study, a deep learning algorithm based on the you-only-look-once (YOLO) approach is proposed for the quality inspection of printed circuit boards (PCBs). The high accuracy and efficiency of deep learning algorithms has resulted in their increased adoption in every field. Similarly, accurate detection of defects in PCBs by using deep learning algorithms, such as convolutional neural networks (CNNs), has garnered considerable attention. In the proposed method, highly skilled quality inspection engineers first use an interface to record and label defective PCBs. The data are then used to train a YOLO/CNN model to detect defects in PCBs. In this study, 11,000 images and a network of 24 convolutional layers and 2 fully connected layers were used. The proposed model achieved a defect detection accuracy of 98.79% in PCBs with a batch size of 32.

1 January 2021 in Mathematical Biosciences and Engineering
Verified
Journal Article
Open access
PDF file
VAVenkat Anil Adibhatla
Venkat Anil Adibhatla
HCHuan-Chuang Chih
Huan-Chuang Chih
CHChi-Chang Hsu
Chi-Chang Hsu
JCJoseph Cheng
Joseph Cheng
MAMaysam F. Abbod
Maysam F. Abbod
Jiann-Shing ShiehJiann-Shing Shieh
Jiann-Shing Shieh
In this paper, a new model known as YOLO-v5 is initiated to detect defects in PCB. In the past many models and different approaches have been implemented in the quality inspection for detection of defect in PCBs. This algorithm is specifically selected due to its efficiency, accuracy and speed. It is well known that the traditional YOLO models (YOLO, YOLO-v2, YOLO-v3, YOLO-v4 and Tiny-YOLO-v2) are the state-of-the-art in artificial intelligence industry. In electronics industry, the PCB is the core and the most basic component of any electronic product. PCB is almost used in each and every electronic product that we use in our daily life not only for commercial purposes, but also used in sensitive applications such defense and space exploration. These PCB should be inspected and quality checked to detect any kind of defects during the manufacturing process. Most of the electronic industries are focused on the quality of their product, a small error during manufacture or quality inspection of the electronic products such as PCB leads to a catastrophic end. Therefore, there is a huge revolution going on in the manufacturing industry where the object detection method like YOLO-v5 is a game changer for many industries such as electronic industries.

23 May 2018 in PeerJ
Verified
Journal Article
Open access
PDF file
QLQuan Liu
Quan Liu
LMLi Ma
Li Ma
SFShou-Zen Fan
Shou-Zen Fan
MAMaysam F. Abbod
Maysam F. Abbod
Jiann-Shing ShiehJiann-Shing Shieh
Jiann-Shing Shieh
Estimating the depth of anaesthesia (DoA) in operations has always been a challenging issue due to the underlying complexity of the brain mechanisms. Electroencephalogram (EEG) signals are undoubtedly the most widely used signals for measuring DoA. In this paper, a novel EEG-based index is proposed to evaluate DoA for 24 patients receiving general anaesthesia with different levels of unconsciousness. Sample Entropy (SampEn) algorithm was utilised in order to acquire the chaotic features of the signals. After calculating the SampEn from the EEG signals, Random Forest was utilised for developing learning regression models with Bispectral index (BIS) as the target. Correlation coefficient, mean absolute error, and area under the curve (AUC) were used to verify the perioperative performance of the proposed method. Validation comparisons with typical nonstationary signal analysis methods (i.e., recurrence analysis and permutation entropy) and regression methods (i.e., neural network and support vector machine) were conducted. To further verify the accuracy and validity of the proposed methodology, the data is divided into four unconsciousness-level groups on the basis of BIS levels. Subsequently, analysis of variance (ANOVA) was applied to the corresponding index (i.e., regression output). Results indicate that the correlation coefficient improved to 0.72 ± 0.09 after filtering and to 0.90 ± 0.05 after regression from the initial values of 0.51 ± 0.17. Similarly, the final mean absolute error dramatically declined to 5.22 ± 2.12. In addition, the ultimate AUC increased to 0.98 ± 0.02, and the ANOVA analysis indicates that each of the four groups of different anaesthetic levels demonstrated significant difference from the nearest levels. Furthermore, the Random Forest output was extensively linear in relation to BIS, thus with better DoA prediction accuracy. In conclusion, the proposed method provides a concrete basis for monitoring patients’ anaesthetic level during surgeries.

26 April 2017 in Frontiers in Human Neuroscience
Verified
Journal Article
Open access
Clint HansenClint Hansen
Clint Hansen
QWQin Wei
Qin Wei
Jiann-Shing ShiehJiann-Shing Shieh
Jiann-Shing Shieh
PFPaul Fourcade
Paul Fourcade
BIBrice Isableu
Brice Isableu
LMLina Majed
Lina Majed
The present study aimed to compare various entropy measures to assess the dynamics and complexity of center of pressure (COP) displacements. Perturbing balance tests are often used in healthy subjects to imitate either pathological conditions or to test the sensitivity of postural analysis techniques. Eleven healthy adult subjects were asked to stand in normal stance in three experimental conditions while the visuo-kinesthetic input was altered. COP displacement was recorded using a force plate. Three entropy measures (Sample Entropy (SE), Multi-Scale Entropy (MSE), and Multivariate Multi Scale Entropy (MMSE)) describing COP regularity at different scales were compared to traditional measures of COP variability. The analyses of the COP trajectories revealed that suppression of vision produced minor changes in COP displacement and in the COP characteristics. The comparison with the reference analysis showed that the entropy measures analysis techniques are more sensitive in the incremented time series compared to the classical parameters and entropy measures of original time series. Non-linear methods appear to be an additional valuable tool for analysis of the dynamics of posture especially when applied on incremental time series.

20 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
BMBhekumuzi Mathunjwa
Bhekumuzi Mathunjwa
YLYin-Tsong Lin
Yin-Tsong Lin
LLLance Lin
Lance Lin
Maysam AbbodMaysam Abbod
Maysam Abbod
MSMuammar Sadrawi
Muammar Sadrawi
Jiann-Shing ShiehJiann-Shing Shieh
Jiann-Shing Shieh
In this paper, an effective electrocardiogram (ECG) recurrence plot (RP)-based arrhythmia classification algorithm that can be implemented in portable devices is presented. Public databases from PhysioNet were used to conduct this study including the MIT-BIH Atrial Fibrillation Database, the MIT-BIH Arrhythmia Database, the MIT-BIH Malignant Ventricular Ectopy Database, and the Creighton University Ventricular Tachyarrhythmia Database. ECG time series were segmented and converted using an RP, and two-dimensional images were used as inputs to the CNN classifiers. In this study, two-stage classification is proposed to improve the accuracy. The ResNet-18 architecture was applied to detect ventricular fibrillation (VF) and noise during the first stage, whereas normal, atrial fibrillation, premature atrial contraction, and premature ventricular contractions were detected using ResNet-50 in the second stage. The method was evaluated using 5-fold cross-validation which improved the results when compared to previous studies, achieving first and second stage average accuracies of 97.21% and 98.36%, sensitivities of 96.49% and 97.92%, positive predictive values of 95.54% and 98.20%, and F1-scores of 95.96% and 98.05%, respectively. Furthermore, a 5-fold improvement in the memory requirement was achieved when compared with a previous study, making this classifier feasible for use in resource-constricted environments such as portable devices. Even though the method is successful, first stage training requires combining four different arrhythmia types into one label (other), which generates more data for the other category than for VF and noise, thus creating a data imbalance that affects the first stage performance.