Nicola Vitiello

Dr. Nicola Vitiello


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 May 2020 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
DPDavid Pinto-Fernández
David Pinto-Fernández
DTDiego Torricelli
Diego Torricelli
MSMaria del Carmen Sanchez-Villamanan
Maria del Carmen Sanchez-Villamanan
FAFelix Aller
Felix Aller
KMKatja Mombaur
Katja Mombaur
JPJose L. Pons
Jose L. Pons
Benchmarks have long been used to verify and compare the readiness level of different technologies in many application domains. In the field of wearable robots, the lack of a recognized benchmarking methodology is one important impediment that may hamper the efficient translation of research prototypes into actual products. At the same time, an exponentially growing number of research studies are addressing the problem of quantifying the performance of robotic exoskeletons, resulting in a rich and highly heterogeneous picture of methods, variables and protocols. This review aims to organize this information, and identify the most promising performance indicators that can be converted into practical benchmarks. We focus our analysis on lower limb functions, including a wide spectrum of motor skills and performance indicators. We found that, in general, the evaluation of lower limb exoskeletons is still largely focused on straight walking, with poor coverage of most of the basic motor skills that make up the activities of daily life. Our analysis also reveals a clear bias towards generic kinematics and kinetic indicators, in spite of the metrics of human-robot interaction. Based on these results, we identify and discuss a number of promising research directions that may help the community to attain a comprehensive benchmarking methodology for robotassisted locomotion more efficiently.

9 January 2014 in Sensors
Verified
Journal Article
Open access
PDF file
SCSimona Crea
Simona Crea
MDMarco Donati
Marco Donati
SRStefano Marco Maria De Rossi
Stefano Marco Maria De Rossi
Calogero Maria OddoCalogero Maria Oddo
Calogero Maria Oddo
NVNicola Vitiello
Nicola Vitiello
This paper introduces the design and development of a novel pressure-sensitive foot insole for real-time monitoring of plantar pressure distribution during walking. The device consists of a flexible insole with 64 pressure-sensitive elements and an integrated electronic board for high-frequency data acquisition, pre-filtering, and wireless transmission to a remote data computing/storing unit. The pressure-sensitive technology is based on an optoelectronic technology developed at Scuola Superiore Sant’Anna. The insole is a low-cost and low-power battery-powered device. The design and development of the device is presented along with its experimental characterization and validation with healthy subjects performing a task of walking at different speeds, and benchmarked against an instrumented force platform.

29 March 2019 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
ETEmilio Trigili
Emilio Trigili
Lorenzo GraziLorenzo Grazi
Lorenzo Grazi
SCSimona Crea
Simona Crea
AAAlessandro Accogli
Alessandro Accogli
JCJacopo Carpaneto
Jacopo Carpaneto
APAlessandro Panarese
Alessandro Panarese
To assist people with disabilities, exoskeletons must be provided with human-robot interfaces and smart algorithms capable to identify the user’s movement intentions. Surface electromyographic (sEMG) signals could be suitable for this purpose, but their applicability in shared control schemes for real-time operation of assistive devices in daily-life activities is limited due to high inter-subject variability, which requires custom calibrations and training. Here, we developed a machine-learning-based algorithm for detecting the user’s motion intention based on electromyographic signals, and discussed its applicability for controlling an upper-limb exoskeleton for people with severe arm disabilities. Ten healthy participants, sitting in front of a screen while wearing the exoskeleton, were asked to perform several reaching movements toward three LEDs, presented in a random order. EMG signals from seven upper-limb muscles were recorded. Data were analyzed offline and used to develop an algorithm that identifies the onset of the movement across two different events: moving from a resting position toward the LED (Go-forward), and going back to resting position (Go-backward). A set of subject-independent time-domain EMG features was selected according to information theory and their probability distributions corresponding to rest and movement phases were modeled by means of a two-component Gaussian Mixture Model (GMM). The detection of movement onset by two types of detectors was tested: the first type based on features extracted from single muscles, whereas the second from multiple muscles. Their performances in terms of sensitivity, specificity and latency were assessed for the two events with a leave one-subject out test method. The onset of movement was detected with a maximum sensitivity of 89.3% for Go-forward and 60.9% for Go-backward events. Best performances in terms of specificity were 96.2 and 94.3% respectively. For both events the algorithm was able to detect the onset before the actual movement, while computational load was compatible with real-time applications. The detection performances and the low computational load make the proposed algorithm promising for the control of upper-limb exoskeletons in real-time applications. Fast initial calibration makes it also suitable for helping people with severe arm disabilities in performing assisted functional tasks.

24 January 2013 in Sensors
Verified
Journal Article
Open access
PDF file
CLChiara Lucarotti
Chiara Lucarotti
Calogero Maria OddoCalogero Maria Oddo
Calogero Maria Oddo
NVNicola Vitiello
Nicola Vitiello
MCMaria Chiara Carrozza
Maria Chiara Carrozza
This paper reviews the state of the art of artificial tactile sensing, with a particular focus on bio-hybrid and fully-biological approaches. To this aim, the study of physiology of the human sense of touch and of the coding mechanisms of tactile information is a significant starting point, which is briefly explored in this review. Then, the progress towards the development of an artificial sense of touch are investigated. Artificial tactile sensing is analysed with respect to the possible approaches to fabricate the outer interface layer: synthetic skin versus bio-artificial skin. With particular respect to the synthetic skin approach, a brief overview is provided on various technologies and transduction principles that can be integrated beneath the skin layer. Then, the main focus moves to approaches characterized by the use of bio-artificial skin as an outer layer of the artificial sensory system. Within this design solution for the skin, bio-hybrid and fully-biological tactile sensing systems are thoroughly presented: while significant results have been reported for the development of tissue engineered skins, the development of mechanotransduction units and their integration is a recent trend that is still lagging behind, therefore requiring research efforts and investments. In the last part of the paper, application domains and perspectives of the reviewed tactile sensing technologies are discussed.

8 January 2020 in IEEE Robotics & Automation Magazine
Verified
Journal Article
Open access
IPIlaria Pacifico
Ilaria Pacifico
ASAlessandro Scano
Alessandro Scano
EGEleonora Guanziroli
Eleonora Guanziroli
MMMatteo Moise
Matteo Moise
LMLuca Morelli
Luca Morelli
SCSimona Crea
Simona Crea

5 August 2020 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
Lorenzo GraziLorenzo Grazi
Lorenzo Grazi
ETEmilio Trigili
Emilio Trigili
GPGiulio Proface
Giulio Proface
FGFrancesco Giovacchini
Francesco Giovacchini
SCSimona Crea
Simona Crea
NVNicola Vitiello
Nicola Vitiello
This paper presents the H-PULSE, a novel semi-passive upper-limb exoskeleton for worker assistance, with motorized tuning of the assistive level. The H-PULSE presents novel design features compared to other passive industrial exoskeletons for the upper limbs, namely joint angle sensors for measuring shoulder flexion/extension and a novel active mechanism for regulating the assistance level. These features could enhance the effectiveness of the system. Along with the presentation of the exoskeleton design, this paper reports on the system experimental evaluation with human subjects. The H-PULSE was assessed in prolonged static overhead tasks under different conditions of assistive support. The set of metrics to evaluate the effects of the device included shoulder muscular activity, heart rate, and subjective user feedback. Results show that the exoskeleton can reduce the users’ muscular activity and the heart rate. Subjective questionnaires allowed the assessment of perceived exoskeleton effectiveness. In this study, the H-PULSE exoskeleton was found to be potentially effective in reducing the muscular strain while reducing the global fatigue level during prolonged continuous overhead activities.