Rotating stall is an unsteady flow phenomenon, which always leads to instability and efficiency degradation. In order to reveal pressure fluctuations in the impeller of centrifugal pump induced by stall cells, the flow structures in a volute-type centrifugal pump were calculated using Large Eddy Simulation (LES) method. The predicted results of the numerical model were compared with experimental flow-head curve. The simulation results were in good agreement with the experimental results. The stall phenomenon occurred when the flow rate dropped to 70% of design flow rate. Three stall cells located at the entrance of passages could be observed, which remained stationary relative to the rotating impeller. With the decrease of flow rate, the area occupied by stall cells gradually increased. The peak value of pressure fluctuation at 25% of design flow rate is obviously larger than that at 50% of design flow rate. For the unstalled or stalled passage, the impeller-volute interaction played a leading role in the pressure fluctuations of the impeller. For the stalled passage, the amplitude of the low frequency induced by stall cell is relatively insignificant.
Artificial intelligence (AI) technologies have been widely applied to the automated detection of pipeline leaks. However, traditional AI methods still face significant challenges in effectively detecting the complete leak process. Furthermore, the deployment cost of such models has increased substantially due to the use of GPU-trained neural networks in recent years. In this study, we propose a novel leak detector, which includes a new model and a sequence labeling method that integrates prior knowledge with traditional reconstruction error theory. The proposed model combines the Kolmogorov–Arnold Network (KAN) with an autoencoder (AE). This model combines the Kolmogorov–Arnold Network (KAN) with an autoencoder (AE), forming a hybrid framework that effectively captures complex temporal dependencies in the data while exhibiting strong pattern modeling and reconstruction capabilities. To improve leak detection, we developed a novel unsupervised anomaly sequence labeling method based on traditional reconstruction error theory, which incorporates an in-depth analysis of the reconstruction error curve along with prior knowledge. This method significantly enhances the interpretability and accuracy of the detection process. Field experiments were conducted on real urban water supply pipelines, and a benchmark dataset was established to evaluate the proposed model and method against commonly used models and methods. The experimental results demonstrate that the proposed model and method achieved a high segment-wise precision of 93.1%. Overall, this study presents a transparent and robust solution for automated pipeline leak detection, facilitating the large-scale, cost-effective development of digital twin systems for urban pipeline leak emergency management.
In order to improve the accuracy of leakage detection in water pipelines, this paper proposes a novel method based on Transformer and transfer learning. A laboratory test platform was established to obtain datasets with rich leakage characteristics. An enhanced feature extraction technique using a shift window input method mapped the NPW sequences into embedding vectors, effectively capturing the fine-grained features while reducing the sequence length, thereby enhancing the Transformer’s retention of sequence details. An improved Transformer encoder was pre-trained on the Experimental pipeline dataset and refined with limited leakage data from real pipelines for accurate detection. Additionally, a novel signal difference-based method was introduced for precise leak localization. The pressure signal was denoised, and the inflection points were identified by subtracting two signals. The points between the inflection and lowest signal points were traversed, with slope calculations optimizing the time delay computations. A leakage simulation test was conducted on a section of a raw water pipeline in Shanghai, and the test results confirmed the effectiveness of these methods. A 100% detection rate, zero false alarms, and a relative positioning error of less than 3.14% were achieved on a test set of 45 instances.
1 November 2016 in IOP Conference Series: Earth and Environmental Science
The performance discontinuity of a pump-turbine under pumping mode is harmful to stable operation of units in hydropower station. In this paper, the performance discontinuity phenomenon of the pump-turbine was studied by means of experiment and numerical simulation. In the experiment, characteristics of the pump-turbine with different diffuser vane openings were tested in order to investigate the effect of pumping casing to the performance discontinuity. While other effects such as flow separation and rotating stall are known to have an effect on the discontinuity, the present studied test cases show that prerotation is the dominating effect for the instability, positions of the positive slope of characteristics are almost the same in different diffuser vane opening conditions. The impeller has principal effect to the performance discontinuity. In the numerical simulation, CFD analysis of tested pump-turbine has been done with k-ω and SST turbulence model. It is found that the position of performance curve discontinuity corresponds to flow recirculation at impeller inlet. Flow recirculation at impeller inlet is the cause of the discontinuity of characteristics curve. It is also found that the operating condition of occurrence of flow recirculation at impeller inlet is misestimated with k-ω and SST turbulence model. Furthermore, the original SST model has been modified. We predict the occurrence position of flow recirculation at impeller inlet correctly with the modified SST turbulence model, and it also can improve the prediction accuracy of the pump- turbine performance at the same time.
In order to study the influence of water-lubricated bearings on the vibration of the marine magnetic pump, the vibration characteristics of the marine magnetic pump under different flow rates and bearing structural parameters (bearing clearance, eccentricity, and length–diameter ratio) were numerically analyzed. The internal flow fields of marine magnetic pumps and water-lubricated bearing were numerically calculated, and experimental verification of their external characteristics results was conducted. The results show that the vibration velocity level of the pump increases with the increase in the bearing clearance and the bearing eccentricity, and the vibration velocity level of the pump gradually decreases with the increase in the bearing length–diameter ratio. The clearance has the greatest influence on the vibration of the pump, the length–diameter ratio the second, and the eccentricity the smallest. The peak value of vibration velocity at the pump outlet at the vibration measurement point is the highest, the peak value of vibration velocity at the pump inlet is second, and the peak value of vibration velocity at the pump foot is the smallest. However, the peak value of vibration velocity at the pump inlet is most sensitive to changes in operating conditions and bearing structural parameters, with a maximum increase of 6.2 dB. Therefore, the change in the peak value of vibration velocity at the pump inlet can be used as the main indicator for monitoring the operating status of bearings.