Zhu Jiang

Prof. Dr. Zhu Jiang


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2023 in Journal of Sensors
Verified
Journal Article
Open access
PDF file
ZJZhu Jiang
Zhu Jiang
JXJunyi Xie
Junyi Xie
JZJing Zhang
Jing Zhang
XZXiang Zhang
Xiang Zhang
In order to solve the problem of low localization accuracy of water supply pipeline leakage detection using acoustic emission signals, a noise reduction algorithm based on variational mode decomposition (VMD) and Hilbert transform is proposed in this paper. Firstly, the leakage signal is decomposed into several intrinsic mode functions (IMF) using VMD, and the number of decomposition layers is determined, and the IMF component is transformed by Hilbert to get the marginal spectrum, and the noise are preliminarily filtered according to the marginal spectrum characteristics and the cross‐correlation coefficient. Secondly, the signal denoising is realized by using filtering technology and cross‐correlation coefficient. Finally, the time delay estimation of the denoised signal is estimated and the location of the leakage point is calculated based on the positioning principle. In order to verify the performance of the algorithm, a water supply pipeline experiment platform for leakage simulation and leak location experiment was conducted. The cross‐correlation algorithm, VMD‐correlation coefficient algorithm, and the proposed algorithm are analyzed through simulation and experiment. The results show that compared with the other two algorithms, the proposed algorithm can effectively remove the noise in the leakage signal and improve the accuracy of leakage location.

31 October 2021 in Journal of Mechanical Science and Technology
Verified
Journal Article
Closed access
PDF file
BLBoxiang Liu
Boxiang Liu
ZJZhu Jiang
Zhu Jiang
WNWei Nie
Wei Nie

10 January 2025 in Sensors
Verified
Journal Article
Open access
PDF file
HWHengyu Wu
Hengyu Wu
ZJZhu Jiang
Zhu Jiang
XZXiang Zhang
Xiang Zhang
JCJian Cheng
Jian Cheng
Artificial intelligence (AI) technologies have been widely applied to the automated detection of pipeline leaks. However, traditional AI methods still face significant challenges in effectively detecting the complete leak process. Furthermore, the deployment cost of such models has increased substantially due to the use of GPU-trained neural networks in recent years. In this study, we propose a novel leak detector, which includes a new model and a sequence labeling method that integrates prior knowledge with traditional reconstruction error theory. The proposed model combines the Kolmogorov–Arnold Network (KAN) with an autoencoder (AE). This model combines the Kolmogorov–Arnold Network (KAN) with an autoencoder (AE), forming a hybrid framework that effectively captures complex temporal dependencies in the data while exhibiting strong pattern modeling and reconstruction capabilities. To improve leak detection, we developed a novel unsupervised anomaly sequence labeling method based on traditional reconstruction error theory, which incorporates an in-depth analysis of the reconstruction error curve along with prior knowledge. This method significantly enhances the interpretability and accuracy of the detection process. Field experiments were conducted on real urban water supply pipelines, and a benchmark dataset was established to evaluate the proposed model and method against commonly used models and methods. The experimental results demonstrate that the proposed model and method achieved a high segment-wise precision of 93.1%. Overall, this study presents a transparent and robust solution for automated pipeline leak detection, facilitating the large-scale, cost-effective development of digital twin systems for urban pipeline leak emergency management.

1 January 2021 in Journal of Sensors
Verified
Journal Article
Open access
PDF file
BLBoxiang Liu
Boxiang Liu
ZJZhu Jiang
Zhu Jiang
WNWei Nie
Wei Nie
Leakage problems are common in the water supply pipeline system, which will threaten the health of residents and cause economic losses. Negative pressure wave (NPW) technology calculates the time difference through the inflection point to locate the leak. However, due to the nonlinear and nonstationary characteristics of the pressure signal, it is difficult to obtain an accurate inflection point of the NPW by the traditional method. Therefore, the advantages of applying variational mode decomposition (VMD) in NPW technology are explored. Firstly, the correlation coefficient and permutation entropy (PE) are used for effective intrinsic mode function (IMF) component selection and parameter optimization. Thus, an adaptive denoising method based on VMD (AD‐VMD) is presented. Then, to effectively separate the detail features of the NPW, a novel inflection point extraction method based on VMD (IPE‐VMD) is proposed. Simulation and experimental results show that AD‐VMD can effectively suppress noise interference and conserve the mutation characteristic of the leakage. IPE‐VMD can obtain a distinct maximum peak at the inflection point and has good robustness to noise interference. This method can calculate the time difference precisely and stably. In addition, the accuracy of the leak location is verified. The average relative positioning error is 5.13%.


28 January 2025 in Water
Verified
Journal Article
Open access
PDF file
JCJian Cheng
Jian Cheng
ZJZhu Jiang
Zhu Jiang
HWHengyu Wu
Hengyu Wu
XZXiang Zhang
Xiang Zhang
In order to improve the accuracy of leakage detection in water pipelines, this paper proposes a novel method based on Transformer and transfer learning. A laboratory test platform was established to obtain datasets with rich leakage characteristics. An enhanced feature extraction technique using a shift window input method mapped the NPW sequences into embedding vectors, effectively capturing the fine-grained features while reducing the sequence length, thereby enhancing the Transformer’s retention of sequence details. An improved Transformer encoder was pre-trained on the Experimental pipeline dataset and refined with limited leakage data from real pipelines for accurate detection. Additionally, a novel signal difference-based method was introduced for precise leak localization. The pressure signal was denoised, and the inflection points were identified by subtracting two signals. The points between the inflection and lowest signal points were traversed, with slope calculations optimizing the time delay computations. A leakage simulation test was conducted on a section of a raw water pipeline in Shanghai, and the test results confirmed the effectiveness of these methods. A 100% detection rate, zero false alarms, and a relative positioning error of less than 3.14% were achieved on a test set of 45 instances.