Jerry L Prince

Prof. Jerry L Prince

orcid

Research Focus & Metrics

Academic Career Length

45Years (1982-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 1998 in IEEE Transactions on Image Processing
Verified
Journal Article
Closed access
CXChenyang Xu
Chenyang Xu
JPJerry L Prince
Jerry L Prince
Snakes, or active contours, are used extensively in computer vision and image processing applications, particularly to locate object boundaries. Problems associated with initialization and poor convergence to boundary concavities, however, have limited their utility. This paper presents a new external force for active contours, largely solving both problems. This external force, which we call gradient vector flow (GVF), is computed as a diffusion of the gradient vectors of a gray-level or binary edge map derived from the image. It differs fundamentally from traditional snake external forces in that it cannot be written as the negative gradient of a potential function, and the corresponding snake is formulated directly from a force balance condition rather than a variational formulation. Using several two-dimensional (2-D) examples and one three-dimensional (3-D) example, we show that GVF has a large capture range and is able to move snakes into boundary concavities.

1 August 2000 in Annual Review of Biomedical Engineering
Verified
Journal Article
Closed access
DPDzung L. Pham
Dzung L. Pham
CXChenyang Xu
Chenyang Xu
JPJerry L Prince
Jerry L Prince
▪ Abstract Image segmentation plays a crucial role in many medical-imaging applications, by automating or facilitating the delineation of anatomical structures and other regions of interest. We present a critical appraisal of the current status of semiautomated and automated methods for the segmentation of anatomical medical images. Terminology and important issues in image segmentation are first presented. Current segmentation approaches are then reviewed with an emphasis on the advantages and disadvantages of these methods for medical imaging applications. We conclude with a discussion on the future of image segmentation methods in biomedical research.

26 February 2021 in Proceedings of the IEEE
Verified
Journal Article
Closed access
SZS. Kevin Zhou
S. Kevin Zhou
HGHayit Greenspan
Hayit Greenspan
CDChristos Davatzikos
Christos Davatzikos
JDJames S. Duncan
James S. Duncan
BGBram Van Ginneken
Bram Van Ginneken
RSRonald M. Summers
Ronald M. Summers
Since its renaissance, deep learning (DL) has been widely used in various medical imaging tasks and has achieved remarkable success in many medical imaging applications, thereby propelling us into the so-called artificial intelligence (AI) era. It is known that the success of AI is mostly attributed to the availability of big data with annotations for a single task and the advances in high-performance computing. However, medical imaging presents unique challenges that confront DL approaches. In this survey article, we first present traits of medical imaging, highlight both clinical needs and technical challenges in medical imaging, and describe how emerging trends in DL are addressing these issues. We cover the topics of network architecture, sparse and noisy labels, federating learning, interpretability, uncertainty quantification, and so on. Then, we present several case studies that are commonly found in clinical practice, including digital pathology and chest, brain, cardiovascular, and abdominal imaging. Rather than presenting an exhaustive literature survey, we instead describe some prominent research highlights related to these case study applications. We conclude with a discussion and presentation of promising future directions.

1 July 1992 in Journal of Cerebral Blood Flow & Metabolism
Verified
Journal Article
Open access
HMHans W. Müller-Gärtner
Hans W. Müller-Gärtner
JLJonathan M. Links
Jonathan M. Links
JPJerry L Prince
Jerry L Prince
RBR. Nick Bryan
R. Nick Bryan
EMElliot McVeigh
Elliot McVeigh
JFJ. James Frost
J. James Frost
Accuracy in in vivo quantitation of brain function with positron emission tomography (PET) has often been limited by partial volume effects. This limitation becomes prominent in studies of aging and degenerative brain diseases where partial volume effects vary with different degrees of atrophy. The present study describes how the actual gray matter (GM) tracer concentration can be estimated using an algorithm that relates the regional fraction of GM to partial volume effects. The regional fraction of GM was determined by magnetic resonance imaging (MRI). The procedure is designated as GM PET. In computer simulations and phantom studies, the GM PET algorithm permitted a 100% recovery of the actual tracer concentration in neocortical GM and hippocampus, irrespective of the GM volume. GM PET was applied in a test case of temporal lobe epilepsy revealing an increase in radiotracer activity in GM that was undetected in the PET image before correction for partial volume effects. In computer simulations, errors in the segmentation of GM and errors in registration of PET and MRI images resulted in less than 15% inaccuracy in the GM PET image. In conclusion, GM PET permits accurate determination of the actual radiotracer concentration in human brain GM in vivo. The method differentiates whether a change in the apparent radiotracer concentration reflects solely an alteration in GM volume or rather a change in radiotracer concentration per unit volume of GM.

1 January 1999 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
DPD.L. Pham
D.L. Pham
JPJerry L Prince
Jerry L Prince
An algorithm is presented for the fuzzy segmentation of two-dimensional (2-D) and three-dimensional (3-D) multispectral magnetic resonance (MR) images that have been corrupted by intensity inhomogeneities, also known as shading artifacts. The algorithm is an extension of the 2-D adaptive fuzzy C-means algorithm (2-D AFCM) presented in previous work by the authors. This algorithm models the intensity inhomogeneities as a gain field that causes image intensities to smoothly and slowly vary through the image space. It iteratively adapts to the intensity inhomogeneities and is completely automated. In this paper, the authors fully generalize 2-D AFCM to three-dimensional (3-D) multispectral images. Because of the potential size of 3-D image data, they also describe a new faster multigrid-based algorithm for its implementation. They show, using simulated MR data, that 3-D AFCM yields lower error rates than both the standard fuzzy C-means (FCM) algorithm and two other competing methods, when segmenting corrupted images. Its efficacy is further demonstrated using real 3-D scalar and multispectral MR brain images.

1 December 1998 in Signal Processing
Verified
Journal Article
Open access
CXChenyang Xu
Chenyang Xu
JPJerry L Prince
Jerry L Prince
Active contours, or snakes, are used extensively in computer vision and image processing applications, particularly to locate object boundaries. A new type of external force for active contours, called gradient vector flow (GVF) was introduced recently to address problems associated with initialization and poor convergence to boundary concavities. GVF is computed as a di⁄usion of the gradient vectors of a gray-level or binary edge map derived from the image. In this paper, we generalize the GVF formulation to include two spatially varying weighting functions. This improves active contour convergence to long, thin boundary indentations, while maintaining other desirable properties of GVF, such as an extended capture range. The original GVF is a special case of this new generalized GVF (GGVF) model. An error analysis for active contour results on simulated test images is also presented. ( 1998 Elsevier Science B.V. All rights reserved.