1 August 2000 in Annual Review of Biomedical Engineering
▪ Abstract Image segmentation plays a crucial role in many medical-imaging applications, by automating or facilitating the delineation of anatomical structures and other regions of interest. We present a critical appraisal of the current status of semiautomated and automated methods for the segmentation of anatomical medical images. Terminology and important issues in image segmentation are first presented. Current segmentation approaches are then reviewed with an emphasis on the advantages and disadvantages of these methods for medical imaging applications. We conclude with a discussion on the future of image segmentation methods in biomedical research.
1 January 1999 in IEEE Transactions on Medical Imaging
An algorithm is presented for the fuzzy segmentation of two-dimensional (2-D) and three-dimensional (3-D) multispectral magnetic resonance (MR) images that have been corrupted by intensity inhomogeneities, also known as shading artifacts. The algorithm is an extension of the 2-D adaptive fuzzy C-means algorithm (2-D AFCM) presented in previous work by the authors. This algorithm models the intensity inhomogeneities as a gain field that causes image intensities to smoothly and slowly vary through the image space. It iteratively adapts to the intensity inhomogeneities and is completely automated. In this paper, the authors fully generalize 2-D AFCM to three-dimensional (3-D) multispectral images. Because of the potential size of 3-D image data, they also describe a new faster multigrid-based algorithm for its implementation. They show, using simulated MR data, that 3-D AFCM yields lower error rates than both the standard fuzzy C-means (FCM) algorithm and two other competing methods, when segmenting corrupted images. Its efficacy is further demonstrated using real 3-D scalar and multispectral MR brain images.
1 September 2007 in Journal of Neuroscience Methods
8 October 2018 in IEEE Transactions on Biomedical Engineering
Objective: To obtain dense spatiotemporal measurements of brain deformation from two distinct but complementary head motion experiments: linear and rotational accelerations. Methods: This study introduces a strategy for integrating harmonic phase analysis of tagged magnetic resonance imaging (MRI) and finite element models to extract mechanically representative deformation measurements. The method was calibrated using simulated as well as experimental data, demonstrated in a phantom including data with image artifacts, and used to measure brain deformation in human volunteers undergoing rotational and linear acceleration. Results: Evaluation methods yielded a displacement error of 1.1 mm compared to human observers, and strain errors between 0.1 $\pm$ 0.2% (mean $\pm$ std. dev.) for linear acceleration and 0.7 $\pm$ 0.3% for rotational acceleration. In the presence of inconsistent or missing data, we demonstrate an approach that can provide an error reduction of 86%. Analysis of results shows consistency with 2D motion estimation, agreement with external sensors, and the expected physical behavior of the brain. Conclusion: Mechanical regularization is useful for obtaining dense spatiotemporal measurements of in-vivo brain deformation under different loading regimes. Significance: The measurements suggest that the brain's 3D response to mild accelerations includes distinct patterns observable using practical MRI resolutions. This type of measurement can provide validation data for computer models for the study of traumatic brain injury (TBI).