Practical application of deep learning based non-intrusive load monitoring (NILM) system requires the deep neural network model to generalize on new unseen data. Existing NILM solutions are not suitable for real-world application due to their poor disaggregation accuracy on new unseen data. In order to address this problem, this paper presents a NILM algorithm that uses data augmentation to generate synthetic data for training deep convolutional neural network models for each target appliance. Proposed data augmentation technique works by combining on and off-durations of a target appliance from various datasets, and forms a unified and comprehensive synthetic aggregate and sub-meter profiles. Apart from proposed algorithm, this paper also proposes an evaluation approach that relies on total predicted energy and ground-truth energy of an appliance to provide detailed insights about total overlapping energy, missing energy and extra energy predicted by the algorithm. Comparison results on our proposed evaluation approach showed that proposed disaggregation algorithm was able to predict energy that was 60% overlapping with ground truth energy and 36% energy was extra. Overall results showed that overlapping energy was 2.5 times more, and extra-predicted energy was 60% less than state-of-the-art algorithms in unseen test cases.
Non-intrusive load monitoring (NILM) is a process of estimating operational states and power consumption of individual appliances, which if implemented in real-time, can provide actionable feedback in terms of energy usage and personalized recommendations to consumers. Intelligent disaggregation algorithms such as deep neural networks can fulfill this objective if they possess high estimation accuracy and lowest generalization error. In order to achieve these two goals, this paper presents a disaggregation algorithm based on a deep recurrent neural network using multi-feature input space and post-processing. First, the mutual information method was used to select electrical parameters that had the most influence on the power consumption of each target appliance. Second, selected steady-state parameters based multi-feature input space (MFS) was used to train the 4-layered bidirectional long short-term memory (LSTM) model for each target appliance. Finally, a post-processing technique was used at the disaggregation stage to eliminate irrelevant predicted sequences, enhancing the classification and estimation accuracy of the algorithm. A comprehensive evaluation was conducted on 1-Hz sampled UKDALE and ECO datasets in a noised scenario with seen and unseen test cases. Performance evaluation showed that the MFS-LSTM algorithm is computationally efficient, scalable, and possesses better estimation accuracy in a noised scenario, and generalized to unseen loads as compared to benchmark algorithms. Presented results proved that the proposed algorithm fulfills practical application requirements and can be deployed in real-time.
27 December 2022 in IEEE Transactions on Sustainable Energy
Battery energy storage (BES) systems play an increasingly important part in power system operation because of their high efficiency and decreasing cost. This article proposes a mixed integer linear programming (MILP) model of battery degradation considering both depth of discharge (DoD) and state of charge (SoC), which can reflect the battery degradation mechanism. To improve computational efficiency for the economic scheduling of power system, a novel one-dimensional linearization is proposed to linearize this two-variable function, which significantly reduces computation burdens without loss of accuracy. Considering the battery degradation cost, a day-ahead economic scheduling model is built and a MILP algorithm is applied to solve it. The effectiveness of the MILP-based battery degradation model for economic scheduling is validated using the modified IEEE 30-bus system. For comparison, other existing battery degradation models are also implemented in the same system.
Global climate deterioration caused by excessive carbon emissions poses a severe threat to the stable operation of power systems. In extreme snow and ice weather, complex faults, such as ice-covered line breakage and insulator flashover, may be triggered. Hybrid simulations to reveal the influence mechanism and dynamic interaction process between extreme weather and power systems have become a research focus. Relationship models between meteorological conditions and grid failure were constructed in ice accretion and insulator flashover scenarios. Based on the above two models, a multi-variable and multi-time scale hybrid simulation of the meteorological process and power system, considering line icing and insulator flashover, was realized. An example was provided to verify the feasibility of the proposed simulation scheme.
As more and more inverter interfaced distributed generators (IIDGs) such as PV are connected to the distribution network (DN), the existing relay protection system may malfunction due to the impact of the IIDGs. In order to evaluate that impact, the fault analysis of the DN with IIDGs is needed and the fault modelling of IIDG is of great significant for the fault analysis and the protection system validation and improvement. This paper proposes a new fault modelling method of IIDG that could consider the detailed characteristics of the inverter in different situations including the limitation of the modulation. The symmetrical fault model of PQ controlled IIDG is deduced by the proposed method, based on which the symmetrical fault analysis of the DN with IIDGs is carried out. The proposed model depicts IIDG as a voltage-controlled current source or a voltage-controlled voltage source according to whether the modulation is limited, therefore covers the full characteristics of the inverter under different conditions, improving the modelling accuracy. The case study based on the modified IEEE 13 nodes system shows that the fault analysis results obtained from the proposed model are more consistent with electromagnetic transient simulation than that of the state-of-art fault model, verifying its effectiveness.