Zaenal Arifin

Mr. Zaenal Arifin

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 November 2018 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
INI Nurhasanah
I Nurhasanah
WSW Safitri
W Safitri
ZAZaenal Arifin
Zaenal Arifin
ASAgus Subagio
Agus Subagio
TWT Windarti
T Windarti
CeO 2 nanoparticles (CeO 2 NPs) have been considered as promising antioxidant and radioprotectant due to its mixed valence state that can prevent cell damage induced by ionizing radiation. The aim of this study is to investigate the antioxidant activity and dose enhancement factor (DEF) of CeO2. The NPs were synthesized by using a precipitation method. The structure of CeO2 NPs was characterized with an X-ray diffractometer (XRD). The antioxidant activity of CeO2 NPs was analyzed by the reduction of 1,1-diphenyl-2-picrylhydrazil (DPPH) stable free radical using UV-vis spectroscopy. The dose enhancement factor (DEF) of CeO2 NPs was examined using X-ray radiation with an energy of 6 MV. The radioprotective ability of CeO2 NPs was evaluated by mixing CeO2 NP suspension with E. coli and exposing it to X-ray radiation with a dose of 2 Gy. The XRD pattern analysis reveals that CeO2 NPs possess a cubic fluorite structure. CeO2 NPs show activity with IC50 value of 4.4 mg/ml. CeO2 NPs also show the ability to absorb X-ray radiation with DEF value < 1 and reduce the E. coli damage induced by X-ray radiation. The amount of irradiated E. coli in the presence of 0.2 mg/ml CeO2 NPs was found to be 23 times larger than that irradiated E. coli in the absence of CeO2 NPs.

31 May 2017 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
INI Nurhasanah
I Nurhasanah
ALA Luthfia
A Luthfia
ZAZaenal Arifin
Zaenal Arifin
Optical properties of CeO2 nanoparticles solution have been studied to explore the possibility of CeO2 nanoparticles as a liquid chemical dosimeter to measure gamma radiation in radiotherapy. CeO2 nanoparticles were synthesized by ultrasound irradiation of cerium nitrate solution. The CeO2 nanoparticles were characterized by X-ray diffraction (XRD) and scanning electron microscope (SEM). CeO2 nanoparticles solution with concentration of 2.5 x 10-4 g/ml was irradiated by 1.3 MV 60Co gamma rays with a dose of 1.0 to 2.5 Gy. The UV absorbance spectrum of unirradiated and irradiated CeO2 nanoparticles solution was measured by using UV-Vis spectrophotometer. The UV absorbance of CeO2 nanoparticles solution increased with increasing radiation dose and caused a change in the band gap. The change in optical properties of CeO2 nanoparticles solution is correlated to chemical reactions induced by gamma radiation. The obtained chemical yield was in the order of 103 mol/J indicates the sensitivity of CeO2 nanoparticles to gamma radiation. The results show the possibility of CeO2 nanoparticles for use as gamma radiation dosimeter.

1 May 2019 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
ZAZaenal Arifin
Zaenal Arifin
EHE Hidayanto
E Hidayanto
BRB Rahayuningsih
B Rahayuningsih
APA A Putri
A A Putri
Evaluated radiation dose and output of general radiographic machine on the thorax and abdomen examination. Radiation output testing on 53 radiographic machine produced 1985-2017 in East Java, Indonesia. For thorax examination, 45-89 kV, 100-200 mA, exposure time 0.01-100 s and abdominal examination, 50-89 kV, 18-320 mA, exposure time is 0.02-100 s. Tests are carried out with the Piranha X-Ray Multimeter. There are reportedly 3 of 53 radiographic machine in the thorax examination as follows: the incident air kerma (INAK), tube output, and entrance surface air kerma (ESAK) rates ranged between 0.019 - 1.604 mGy, 0.0004 - 0.0057 mGy/mAs, and 0.024 - 2.101 mGy. While on abdominal examination, the INAK, tube output, and ESAK rates ranged between 0.009 - 2.710 mGy, 0.014 - 0.072 mGy/mAs, and 0.013 - 3.660 mGy., From data with various brands, general radiographic machine in East Java, for Thorax and Abdomen examination INAK values are below 1,604 mGy, 2,710 mGy, values are below 0.0057 mGy / mAs, 0.072 mGy / mAs, and ESAK values are below 2,101 mGy, 2,710 mGy and still within the limits permitted by the BAPETEN regulation in Indonesia.

1 May 2019 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
SAS Y Astuti
S Y Astuti
HSHeri Sutanto
Heri Sutanto
GJG W Jaya
G W Jaya
EHE Hidayanto
E Hidayanto
ZAZaenal Arifin
Zaenal Arifin
Radiodiagnostics are diagnostics utilizing X-rays or radiochemical tracers. At the time of exposure using radiation, there may be radiation exposure that will affect the radiation workers. The purpose of this research is to develop materials that can be used as radiation shielding while maintaining radiodiagnostic examination results. This material is made by combining silicone rubber (SR) and silica composites materials through a simple process with a sample size (12 x 12 x 0.5 cm3). Samples were made in 2 variations using silicone rubber and silicone rubber-6% silica composite. Both samples were then tested using a mobile X-ray plane with tube voltage variations of 46 kV, 50 kV, 60 kV, 70kV, 81kV, 90kV, and 102kV, respectively. After being tested, the results of the X-ray transmission percentage for SR sheet at the minimum and maximum voltage are 60% and 75%, respectively. For SR-6% Silica sheet X-ray transmission percentage at the minimum and maximum stresses of 58% and 74%, respectively. This research results showed that the use of silica on SR has potential as a composite material that can provide increased absorption of X-ray radiation.

1 May 2019 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
HSHeri Sutanto
Heri Sutanto
GWG Wjaya
G Wjaya
EHE Hidayanto
E Hidayanto
ZAZaenal Arifin
Zaenal Arifin

24 May 2022 in Biomedical Physics & Engineering Express
Verified
Journal Article
Open access
EHEko Hidayanto
Eko Hidayanto
HSHeri Sutanto
Heri Sutanto
IMIndras Marhaendrajaya
Indras Marhaendrajaya
GJGede Wiratma Jaya
Gede Wiratma Jaya
ZAZaenal Arifin
Zaenal Arifin
Geoff DoughertyGeoff Dougherty
Geoff Dougherty
A bolus is a material equivalent to soft tissue and is directly placed on the skin surface during radiotherapy. It is commonly used to increase the dose on the skin surface in electron beam radiation. A typical material for a bolus is silicone rubber (SR). We made a bolus with dimensions of 17 × 17 × 1 cm3 by varying silicone rubber (SR) RTV 52 and hardening material (bluesil catalyst 60 R) using a simple molded method. We characterized it using a CT scan to find the relative electron density (RED) and examined it using the electron beam of a linear accelerator (LINAC) at energies of 5 and 7 MeV to investigate the percentage of surface dose (PSD). The PSD value is relative to the dose at maximum doses (dmax). The RED value of the bolus was from 1.168 ± 0.021 to 1.176 ± 0.019, higher than the soft tissue (muscle) value of 1.043. The percentage of surface dose (PSD) test at 5 and 7 MeV LINAC energy showed that the highest PSD without using a bolus were 84.79 ± 0.06% and 86.03 ± 0.07%, respectively. With a bolus, the PSD values were 112.52 ± 0.16% and 111.14 ± 0.03%, respectively. The results indicate that bolus fabrication using SR RTV 52 and bluesil 60R is very effective for radiotherapy in the treatment of skin cancer due to an increase in surface dose.