Ning Yue Cheng

Prof. Dr. Ning Yue Cheng


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 January 2015 in BMC Veterinary Research
Verified
Journal Article
Open access
PDF file
JWJianke Wang
Jianke Wang
NCNing Yue Cheng
Ning Yue Cheng
MZMiao Zhang
Miao Zhang
HZHang Zhao
Hang Zhao
PLPeng Lin
Peng Lin
SCShipeng Cheng
Shipeng Cheng
Mink enteritis virus (MEV) causes mink viral enteritis, an acute and highly contagious disease whose symptoms include violent diarrhea, and which is characterized by high morbidity and mortality. Nanoparticle-assisted polymerase chain reaction (nanoPCR) is a recently developed technique for the rapid detection of bacterial and viral DNA. Here we describe a novel nanoPCR assay for the clinical detection and epidemiological characterization of MEV. This assay is based upon primers specific for the conserved region of the MEV NS1 gene, which encodes nonstructural protein 1. Under optimized conditions, the MEV nanoPCR assay had a detection limit of 8.75 × 101 copies recombinant plasmids per reaction, compared with 8.75 × 103 copies for conventional PCR analysis. Moreover, of 246 clinical mink samples collected from five provinces in North-Eastern China, 50.8% were scored MEV positive by our nanoPCR assay, compared with 32.5% for conventional PCR. Furthermore no cross reactivity was observed for the nanoPCR assay with respect to related viruses, including canine distemper virus (CDV) and Aleutian mink disease parvovirus (AMDV). Phylogenetic analysis of four Chinese wild type MEV isolates using the nanoPCR assay indicated that they belonged to a small MEV clade, named “China type”, in the MEV/FPLV cluster, and were closely clustered in the same location. Our results indicate that the MEV China type clade is currently circulating in domestic minks in China. We anticipate that the nanoPCR assay we have described here will be useful for the detection and epidemiological and pathological characterization of MEV.

10 May 2019 in BMC Veterinary Research
Verified
Journal Article
Open access
PDF file
YSYaru Sun
Yaru Sun
NCNing Yue Cheng
Ning Yue Cheng
PLPeng Lin
Peng Lin
HZHewei Zhang
Hewei Zhang
LYLi Yi
Li Yi
JWJianke Wang
Jianke Wang
Canine parvovirus (CPV) and feline parvovirus (FPV) are causative agents of diarrhea in dogs and cats, which manifests as depression, vomiting, fever, loss of appetite, leucopenia, and diarrhea in young animals. CPV and FPV can single or mixed infect cats and cause disease. To diagnose sick animals effectively, an effective virus diagnostic and genome typing method with high sensitivity and specificity is required. In this study, a conserved segment containing one SNP A4408C of parvovirus was used for real-time PCR amplification. Subsequently, data were auto-analyzed and plotted using Applied Biosystems® High Resolution Melt Software v3.1. Results showed that CPV and FPV can be detected simultaneously in a single PCR reaction. No cross-reactions were observed with canine adenovirus, canine coronavirus, and canine distemper virus. The assay had a detection limit of 4.2 genome copies of CPV and FPV. A total of 80 clinical samples were subjected to this assay, as well as to conventional PCR-sequence assay and virus isolation. Results showed that the percentage of agreement of the assay and other methods are high. In short, we have developed a diagnostic test for the accurate detection and differentiation of CPV and FPV in fecal samples, which is also cost effective.

27 October 2022 in BMC Veterinary Research
Verified
Journal Article
Open access
PDF file
JYJingfei Ye
Jingfei Ye
ZLZhijie Li
Zhijie Li
FSfeiyan sun
feiyan sun
LGli guo
li guo
EFErkai Feng
Erkai Feng
NCNing Yue Cheng
Ning Yue Cheng
Background: Feline calicivirus (FCV), Feline panleukopenia virus (FPV), and Feline herpesvirus type I (FHV-1) are the three most common pathogens in cats, and also are the main pathogens leading to the death of kittens. Here, by a combination of gold nanoparticles and conventional PCR, we established a novel triple NanoPCR molecular detection method for clinical detection. Results: The triple NanoPCR molecular detection is able to detect 2.97 × 101copies/μL FCV recombinant copies plasmid per reaction, 2.64 × 104copies/μL FPV recombinant copies plasmid per reaction, and 2.85copies/μL FHV-1 recombinant copies plasmid per reaction at the same time. The sensitivity of each plasmid is 100 times, 10 times, and 100 times higher than conventional PCR, respectively. The clinical results showed that among the 38 samples, the positive rates of FCV, FPV, and FHV-1 in a NanoPCR test were 63.16, 31.58, and 60.53%, while in a conventional PCR were 39.47, 18.42, and 34.21%. Conclusions: In this report, it is the first time that NanoPCR assays are applied in the detection of FCV, FPV, and FHV-1 as well. This sensitive and specific NanoPCR assay can be widely used in clinical diagnosis and field monitoring of FCV, FPV, and FHV-1 infections.

16 November 2023 in Frontiers in Microbiology
Verified
Journal Article
Open access
MYManping Yan
Manping Yan
JSJinyuan Shang
Jinyuan Shang
XZXiaohao Zhang
Xiaohao Zhang
SWShun Wu
Shun Wu
CWChunxia Wang
Chunxia Wang
EFErkai Feng
Erkai Feng
Feline calicivirus (FCV) and Feline herpesvirus type I (FHV-I) are the main pathogens causing upper respiratory tract infections in cats, and some wild animals. These two viruses always coinfection and cause serious harm to pet industry and wild animals protection. Established a rapid and accurate differential diagnosis method is crucial for prevention and control of disease, however, the current main detection method for these two viruses, either is low sensitivity (immunochromatographic strip), or is time-consuming and cannot differential diagnosis (conventional single PCR). Nanoparticle-assisted polymerase chain reaction (Nano-PCR) is a recently developed technique for rapid detection method of virus and bacteria. In this study, we described a dual Nano-PCR assay through combining the nanotechnology and PCR technology, which for the clinical simultaneous detection of FCV and FHV-I and differential diagnosis of upper respiratory tract infections in cats or other animals. Under optimized conditions, the optimal annealing temperature for dual Nano-PCR was 51.5°C, and specificity test results showed it had no cross reactivity to related virus, such as feline panleukopenia virus (FPV), feline Infectious peritonitis virus (FIPV) and rabies virus (RABV). Furthermore, the detection limit of dual Nano-PCR for FCV and FHV-I both were 1 × 10−8 ng/μL, convert to number of copies of virus DNA was 6.22 × 103copies/μL (FCV) and 2.81 × 103copies/μL (FHV-I), respectively. The dual Nano-PCR detected result of 52 cat clinical samples, including ocular, nasal and faecal swabs, and (3 FCV-positive samples), was consistent with ordinary PCR and the clinical detection results. The dual Nano-PCR method established in this study with strong specificity and high sensitivity can be used for virus nucleic acid (FCV and FHV-I) detection of clinical samples of feline upper respiratory tract infections feline calicivirus and feline herpesvirus while providing support for the early diagnosis of cats that infected by FCV and FHV-I.

27 March 2024 in Frontiers in Veterinary Science
Verified
Journal Article
Open access
YWYan Wang
Yan Wang
JSJinyuan Shang
Jinyuan Shang
ZLZhijie Li
Zhijie Li
AZAo Zhang
Ao Zhang
NCNing Yue Cheng
Ning Yue Cheng
Bovine Viral Diarrhea Virus (BVDV) and Infectious Bovine Rhinotracheitis Virus (IBRV) are the two most prevalent infectious diseases in cattle. They both can cause persistent infection and immunosuppression, resulting in significant economic losses in the livestock industry. Therefore, rapid detection of early BVDV and IBRV infections is crucial. In this study, a method for the rapid detection of BVDV and IBRV was established by using recombinase polymerase amplification (RPA) combined with lateral flow device (LFD). By optimizing the temperature and time conditions of the RPA reaction, the sensitivity, specificity, and clinical performance were evaluated. The results indicated that the RPA reaction could be completed at 40°C within 25 min. The LOD for BVDV and IBRV by RPA-LFD were 5.1 × 101 copies/μL and 6.65 × 101 copies/μL, respectively, with no cross-reactivity observed with other viruses such as CSFV, BRSV, BPIV3, BRV, and BCoV. Testing of 32 clinical samples showed consistent results between RPA-LFD and qPCR. The RPA-LFD method established in this study can be used for the rapid clinical detection of BVDV and IBRV, which providing a rapid and convenient molecular biology approach for on-site rapid detection and epidemiological investigations. Simultaneously, it offers technical support for the prevention and control of these viruses.

27 September 2024 in BMC Biotechnology
Verified
Journal Article
Open access
PDF file
JSJinyuan Shang
Jinyuan Shang
MYManping Yan
Manping Yan
XZXiaohao Zhang
Xiaohao Zhang
WLWei Liu
Wei Liu
SWShun Wu
Shun Wu
GLGuoliang Luo
Guoliang Luo
This study introduces a novel diagnostic modality for the detection of feline panleukopenia virus (FPV) antibodies in feline serum by using fluorescent microsphere immunochromatographic test strips (FM-ICTS). Leveraging the inherent specificity of antigen-antibody interactions, the FM-ICTS approach demonstrates considerable potential for efficient and accurate FPV antibody detection within a short timeframe. The FM-ICTS method demonstrates strong diagnostic performance, with consistent accuracy and stability over time. PBS buffer dilution enables detection across the range of FPV antibody haemagglutination inhibition (HI) titres in both healthy and immunized or infected cats. A high correlation (R² = 0.9733) between the T/C ratio and FPV antibody titres confirms the method’s effectiveness in quantifying these titres. Clinical validation with 84 samples supports its reliability by matching results with HI assays. Additionally, stability tests show that the test strips maintain performance during storage, with a coefficient of variation (CV) below 12% over three months at 25℃. This innovative FM-ICTS framework emerges as a promising avenue for expedient and dependable disease diagnosis within the realm of veterinary science, offering implications for timely disease management and surveillance.