Sally Shahzad

Dr. Sally Shahzad


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2018 in Energy and Buildings
Verified
Journal Article
Closed access
SSSally Shahzad
Sally Shahzad
John Kaiser CalautitJohn Kaiser Calautit
John Kaiser Calautit
KCKatrina Calautit
Katrina Calautit
BHBen Hughes
Ben Hughes
AAAngelo I. Aquino
Angelo I. Aquino

25 January 2018 in Building Services Engineering Research & Technology
Verified
Journal Article
Closed access
PDF file
SSSally Shahzad
Sally Shahzad
JBJohn Brennan
John Brennan
DTDimitris Theodossopoulos
Dimitris Theodossopoulos
JCJohn K Calautit
John K Calautit
BHBen R Hughes
Ben R Hughes
The neutral thermal sensation (neither cold, nor hot) is widely used through the application of the ASHRAE seven-point thermal sensation scale to assess thermal comfort. This study investigated the application of the neutral thermal sensation and it questions the reliability of any study that solely relies on neutral thermal sensation. Although thermal-neutrality has already been questioned, still most thermal comfort studies only use this measure to assess thermal comfort of the occupants. In this study, the connection of the occupant’s thermal comfort with thermal-neutrality was investigated in two separate contexts of Norwegian and British offices. Overall, the thermal environment of four office buildings was evaluated and 313 responses (three times a day) to thermal sensation, thermal preference, comfort, and satisfaction were recorded. The results suggested that 36% of the occupants did not want to feel neutral and they considered thermal sensations other than neutral as their comfort condition. Also, in order to feel comfortable, respondents reported wanting to feel different thermal sensations at different times of the day suggesting that occupant desire for thermal comfort conditions may not be as steady as anticipated. This study recommends that other measures are required to assess human thermal comfort, such as thermal preference. Practical application: This study questions the application of neutral thermal sensation as the measure of thermal comfort. The findings indicate that occupant may consider other sensations than neutral as comfortable. This finding directly questions the standard comfort zone (e.g. ASHRAE Standard 55) as well as the optimum temperature, as many occupants required different thermal sensations at different times of the day to feel comfortable. These findings suggest that a steady indoor thermal environment does not guarantee thermal comfort and variations in the room temperature, which can be controlled by the occupant, need to be considered as part of the building design.

1 January 2017 in Applied Energy
Verified
Journal Article
Closed access
SSSally Shahzad
Sally Shahzad
JBJohn Brennan
John Brennan
DTDimitris Theodossopoulos
Dimitris Theodossopoulos
BHBen Hughes
Ben Hughes
John Kaiser CalautitJohn Kaiser Calautit
John Kaiser Calautit

1 November 2015 in Renewable Energy
Verified
Journal Article
Closed access
John Kaiser CalautitJohn Kaiser Calautit
John Kaiser Calautit
BHBen Richard Hughes
Ben Richard Hughes
SSSally Shahzad
Sally Shahzad

1 December 2017 in Applied Energy
Verified
Journal Article
Closed access
SSSally Shahzad
Sally Shahzad
John Kaiser CalautitJohn Kaiser Calautit
John Kaiser Calautit
AAAngelo I. Aquino
Angelo I. Aquino
DNDiana S.N.M. Nasir
Diana S.N.M. Nasir
BHBen Richard Hughes
Ben Richard Hughes

6 April 2016 in Sustainability
Verified
Journal Article
Open access
PDF file
SSSally Shahzad
Sally Shahzad
John BrennanJohn Brennan
John Brennan
DTDimitris Theodossopoulos
Dimitris Theodossopoulos
BHBen Richard Hughes
Ben Richard Hughes
John Kaiser CalautitJohn Kaiser Calautit
John Kaiser Calautit
This study compared building-related symptoms in personal and open plan offices, where high and low levels of control over the thermal environment were provided, respectively. The individualized approach in Norway provided every user with a personal office, where they had control over an openable window, door, blinds, and thermostat. In contrast, the open plan case studies in the United Kingdom provided control over openable windows and blinds only for limited occupants seated around the perimeter of the building, with users seated away from the windows having no means of environmental control. Air conditioning was deployed in the Norwegian case study buildings, while displacement ventilation and natural ventilation were utilized in the British examples. Field studies of thermal comfort were applied with questionnaires, environmental measurements, and interviews. Users’ health was better in the Norwegian model (28%), while the British model was much more energy efficient (up to 10 times). The follow-up interviews confirmed the effect of lack of thermal control on users’ health. A balanced appraisal was made of energy performance and users’ health between the two buildings.