Background: Left atrial posterior wall isolation (LAPWI) may improve rhythm control in addition to pulmonary vein isolation (PVI) in persistent atrial fibrillation (persAF) patients undergoing catheter ablation (CA). However, LAPWI may be challenging when using thermal energy sources. Objective: This study aimed to investigate the efficacy and safety of LAPWI performed by non-thermal pulsed field ablation (PFA) in CA for persAF. Methods: Consecutive persAF patients from two German centers were prospectively enrolled. There were two study cohorts: (1) the LAPWI cohort, which included PFA-guided (re-)PVI with LAPWI for first-time and/or repeat ablation procedures; and (2) a comparative persAF cohort with a PFA PVI-only approach without LAPWI for first-time ablation within the same timeframe. Patients were followed up by routine Holter ECGs. Results: In total, 79 persistent AF patients were included in the study: 59/79 patients were enrolled in the LAPWI cohort, including 16/59 index (27%) and 43/59 repeat ablation procedures (73%). Sixteen patients (16/79; 21%) were in the PVI-only cohort without LAPWI. Of the patients treated with LAPWI, procedure time and fluoroscopy time was 91 ± 30 min and 15 ± 7 min, respectively. The acute PVI rate was 100% in all first-time ablation patients (32 patients (16 PVI only, 16 PVI plus LAPWI), 196/196 PVs). Of the 43 re-do patients in the LAPWI cohort, re-PVI was necessary in 33% (14/43) of patients (27 PVs; 1.9 PV per-patient); in 67% (29/43), all PVs were isolated, and antral ablation of the PV ostia was performed in 48% (14/29). LAPWI was performed successfully in all 59 (100%) patients of the LAPWI cohort. Two minor complications occurred. No esophageal lesion was detected in the LAPWI cohort (n = 33/59 (56%) patients underwent endoscopy). After 354 ± 197 days of follow-up, freedom from atrial arrhythmias was 79.3% (95-CI: 62–95%) in the complete LAPWI cohort (n = 14/59 (24%) on AAD: class Ic n = 9, class III n = 5). There was no difference regarding acute procedural and clinical outcome compared to the PVI-only cohort. Conclusion: LAPWI guided by PFA is feasible and safe in patients undergoing CA for persAF and shows favorable outcomes. In the context of durable PVI, PFA-guided LAPWI may be an effective adjunctive treatment option.
Experimental studies and clinical reports suggest antiarrhythmic properties of mexiletine in different arrhythmias. We aimed at investigating mexiletine in experimental models of atrial fibrillation (AF) as well as in long-QT- (LQTS) and short-QT-syndrome (SQTS). In 15 isolated rabbit hearts, erythromycin (300 µM) was infused for simulation of long-QT-2-syndrome. In further 13 hearts, veratridine was administered to simulate long-QT-3-syndrome. Both drugs induced a significant QT-prolongation (erythromycin: +87 ms, P < 0.01; veratridine: +19 ms, P < 0.05) and increased dispersion of repolarization (erythromycin: +55 ms, P < 0.01; veratridine +31 ms, P < 0.01). Additional infusion of mexiletine (25 µM) resulted in a significant reduction of dispersion (erythromycin: −43 ms, P < 0.01; veratridine: −26 ms, P < 0.05). Reproducible induction of torsade de pointes was observed in 13 of 15 erythromycin-treated hearts (192 episodes) and 6 of 13 veratridine-treated hearts (36 episodes). Additional infusion of mexiletine significantly reduced ventricular tachycardia (VT) incidence. With mexiletine, only 3 of 15 erythromycin-treated hearts (27 episodes) and 1 of 13 veratridine-treated hearts (2 episodes) presented polymorphic VT. In additional 9 hearts, the IK-ATP-channel-opener pinacidil was employed to simulate SQTS and significantly abbreviated ventricular repolarization (QT-interval: −18 ms, P < 0.05) and enhanced induction of ventricular fibrillation (VF). Mexiletine reversed the effects of pinacidil, increase refractory period (+127 ms, P < 0.01) and significantly suppressed induction of VF. In further 13 hearts AF was induced by combined treatment with acetylcholine/isoproterenol. Mexiletine also increased atrial refractory period (+80 ms, P < 0.01) and thereby effectively suppressed atrial fibrillation. Acute infusion of mexiletine significantly reduced the occurrence of polymorphic VT in the presence of pharmacologically simulated LQTS. Furthermore, mexiletine demonstrated potent antiarrhythmic properties in a model of SQTS and in AF.
Background: Several case reports have suggested an increased risk of sudden cardiac death due to energy drinks. Therefore, the purpose of this study was to assess acute electrophysiologic effects of caffeine and taurine, two of the main ingredients of energy drinks, in an experimental whole‐heart model.Methods and Results: Twenty‐five rabbit hearts were excised, retrogradely perfused, and assigned to two groups. Hearts were perfused with caffeine (2, 10, and 50 µM) or taurine (2, 10, and 50 µM) after generating baseline data. Eight monophasic action potentials and electrocardiography recordings showed a significant abbreviation of action potential duration (APD90), QT interval, and effective refractory periods (ERP) after caffeine treatment. With taurine, cardiac repolarization duration and ERP were significantly shortened. A ventricular vulnerability was assessed by a predefined pacing protocol. With caffeine, we observed a trend towards more ventricular arrhythmias in a dose‐dependent manner. After treatment with taurine, significantly more episodes of ventricular arrhythmias occurred.Conclusion: In this experimental whole‐heart study, treatment with caffeine and taurine provoked ventricular arrhythmias. The underlying mechanism was an abbreviation of cardiac repolarizations and effective refractory periods that may facilitate re‐entry and thereby provokes arrhythmias. These findings help to understand the potentially hazardous and fatal outcomes after intoxication with energy drinks.
1 June 2017 in International Journal of Cardiology
Previous studies suggest an impact of dexmedetomidine on cardiac electrophysiology. However, experimental data is sparse. Therefore, purpose of this study was to investigate the influence of dexmedetomidine on different experimental models of proarrhythmia. 50 rabbit hearts were explanted and retrogradely perfused. The first group (n = 12) was treated with dexmedetomidine in ascending concentrations (3, 5 and 10 µM). Dexmedetomidine did not substantially alter action potential duration (APD) but reduced spatial dispersion of repolarization (SDR) and rendered the action potentials rectangular, resulting in no proarrhythmia. In further 12 hearts, erythromycin (300 µM) was administered to simulate long-QT-syndrome-2 (LQT2). Additional treatment with dexmedetomidine reduced SDR, thereby suppressing torsade de pointes. In the third group (n = 14), 0.5 µM veratridine was added to reduce the repolarization reserve. Further administration of dexmedetomidine did not influence APD, SDR or the occurrence of arrhythmias. In the last group (n = 12), a combination of acetylcholine (1 µM) and isoproterenol (1 µM) was used to facilitate atrial fibrillation. Additional treatment with dexmedetomidine prolonged the atrial APD but did not reduce AF episodes. In this study, dexmedetomidine did not significantly alter cardiac repolarization duration and was not proarrhythmic in different models of ventricular and atrial arrhythmias. Of note, dexmedetomidine might be antiarrhythmic in acquired LQT2 by reducing SDR.