Partial Shading Condition drastically reduces the maximum power output of Photovoltaic array. Partial shading occurs due to several factors such as; flying birds, trees and passing clouds, etc. Many ways can be mitigated partial shading problems in PV array. One among the way is reconfiguration techniques, namely reconfigure the location of PV modules in PV array based on irradiance levels in order to distribute shading effects and increasing maximum power. This paper proposed an optimal SuDoKu reconfiguration pattern for 9 × 9 Total-Cross- Tied PV array to improve maximum power under partial shading conditions. In this approach, the physical location of PV modules in TCT array are rearranged based on optimal SuDoKu style without altering the electrical connections, so that the shading effects can distribute over the array. Further, the performance of proposed pattern investigated with existing SuDoKu pattern under different shading conditions by comparing the Global Maximum Power Point, Mismatch Losses, Fill-Factor and Efficiency using Matlab-Simulink. Based on the results of this paper, it concluded that the proposed optimal SuDoKu reconfiguration arrangement is reducing the line losses and disperse the shading effects over the array as compared to SuDoKu arrangement.
1 February 2022 in Electric Power Systems Research
This paper presents an application of an actor-critic reinforcement learning (RL) algorithm-based adaptive proportional-integral-derivative (PID) controller for automatic generation control of multi-area power systems. The proposed approach has several advantages over other deep RL algorithm-driven PID controllers, such as simplicity in structure, elimination of pre-learning requirements, and prior tuning of PID parameters. Online adaption of PID parameters is achieved through actor-critic policy. The proposed method implements a single radial basis function (RBF) based neural network for actor and critic networks. Three different case studies are demonstrated with proper illustration and analysis of the result to present the effectiveness and robustness of the proposed control strategy against various uncertainties. The outcomes of the proposed controller are compared with the conventional PID controller tuned by the Particle Swarm Optimization (PSO) algorithm. The results seem competent enough to maintain the frequency within an acceptable limit under various uncertainties. Note to Practitioners —This paper describes the application of an online adaptive PID controller for automatic generation control of power systems. The controller is designed using a model-free reinforcement learning algorithm, which enables it to control the system without requiring prior knowledge of the system dynamics. Additionally, the controller does not need any global optimization algorithm for tuning the parameters ( $K_P$ , $K_I$ , $K_D$ ) beforehand. This controller can be implemented for both linear and non-linear systems.
1 November 2015 in IET Generation, Transmission & Distribution
In this study, a new reactive power loss index (RPLI) is proposed for identification of weak buses in the system. This index is further used for determining the optimal locations for placement of reactive compensation devices in the power system for additional voltage support. The new index is computed from the reactive power support and loss allocation algorithm using Y ‐bus method for the system under intact condition and as well as critical/severe network contingencies cases. Fuzzy logic approach is used to select the important and critical/severe line contingencies from the contingency list. The inherent characteristics of the reactive power in system operation is properly addressed while determining the reactive power loss allocation to load buses. The proposed index is tested on sample 10‐bus equivalent system and 72‐bus practical equivalent system of Indian southern region power grid. The validation of the weak buses identification from the proposed index with that from other existing methods in the literature is carried out to demonstrate the effectiveness of the proposed index. Simulation results show that the identification of weak buses in the system from the new RPLI is completely non‐iterative, thus requires minimal computational efforts as compared with other existing methods in the literature.